manual abstract
• Location should be out of high traffic areas and away from furniture and draperies due to heat from firebox. • Never obstruct the front opening of the unvented firebox or restrict the flow of combustion and ventilation air. • Minimize modifications to existing construction. See Figure 1 for location suggestions. WARNING: MAINTAIN MINIMUM CLEARANCES. Do not install in the vicinity where gasoline or other flammable liquids may be stored. The unvented firebox must be kept clear and free from these combustible materials. CAUTION: HEATERS CREATE WARM AIR CURRENTS. THESE CURRENTS MOVE HEAT TO WALL SURFACES NEXT TO HEATER. INSTALLING HEATER NEXT TO VINYL OR CLOTH WALL COVERINGS OR OPERATING HEATER WHERE IMPURITIES IN THE AIR (SUCH AS TOBACCO SMOKE) EXISTS, MAY DISCOLOR WALLS. WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE. AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS. WARNING: DO NOT USE A BLOWER INSERT, HEAT EXCHANGER INSERT OR OTHER ACCESSORY NOT APPROVED FOR USE WITH THIS FIREPLACE. Not to Scale Figure 1 Clearances WARNING: DO NOT INSTALL THESE BUILT-IN UNVENTED FIREBOXES IN SLEEPING QUARTERS, OR IN RECREATIONAL VEHICLES. WARNING: DO NOT INSTALL THESE APPLIANCES: • WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42" FROM THE FRONT OF THE UNVENTED ROOM HEATER. • IN HIGH TRAFFIC AREAS. • IN WINDY OR DRAFTY AREAS. Ensure the minimum clearances shown in Figures 2 and 3 are maintained. Left and right clearances are determined when facing the front of the firebox. Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may create a fire hazard. Sidewall clearances: The sides of the firebox opening must be at least 16" from any combustible wall (Figure 2). Optional Hearth Extension Figure 2 Ceiling clearance: The ceiling must be at least 40" from the top of the firebox opening (Figure 2). Noncombustible material: Noncombustible materials, such as slate and marble, must be at least ..." thick and may be used without restriction above the firebox opening, to the sides or as a hearth extension, so long as they do not obstruct vent openings for heat circulating models. 40" 16" NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18" Min. 9" Min. FireplaceOpening Spacer Combustible Mantel and Trim 8" Max. 3" Finished Wall Header Canopy Safe Zone 18" Min. 9" Min. FireplaceOpening Spacer Combustible Mantel and Trim 8" Max. 3" Finished Wall Header Canopy Safe Zone Noncombustible material (minimum requirements) with wood mantel or other combustible projections: To install the firebox with a wood mantel, shelf or other combustible projection above firebox opening. Refer to Figure 3. WARNING: THE CANOPY HOOD MUST BE IN PLACE TO BE IN COMPLIANCE WITH THE CLEARANCES SPECIFIED IN FIGURE 3. DO NOT REMOVE OR REPLACE CANOPY, ONLY USE CANOPY SUPPLIED WITH THE FIREBOX. DO NOT USE ANY CANOPY WHICH MAY BE PROVIDED WITH THE DECORATIVE TYPE UNVENTED ROOM HEATER. If your mantel profile is unsa...
Other models in this manual:Fireplaces - UNVENTED FIREBOXES UVFC-500 (2.24 mb)
Fireplaces - UNVENTED FIREBOXES UVFC-600 (2.24 mb)
Fireplaces - UNVENTED FIREBOXES UVFC-500 (2.24 mb)
Fireplaces - UNVENTED FIREBOXES UVFC-500 (2.24 mb)