manual abstract
The enclosure surrounding the fireplace on the sides and back must be treated as an exterior wall. Lennox does provide this optional drain pan to assist weatherproofing the fireplace. H4651 DPSS36 Drain Pan for E36ODG, H4652 DPSS42 Drain Pan for E42ODG. INSTALLATION INSTRUCTIONS When Planning for the installation of the fireplace, the framing height must be increased from 46-1/2 inches to 47-1/4 inches, when installing the drain pan. An additional space below the fireplace will also be required to plumb a drain line. Step 1. Seal all joints, gaps and corners around the bottom of the drain pan before positioning the fireplace on its location (Figure 1 ). Step 2. On the exposed drain hole, install a PVC threaded coupling reducer, 3/4" x 1/2" going from the top of the pan, down through the hole. Apply a silicone-based sealant around the base and threads before installation. Step 3. Holding the reducer coupling with a wrench, thread a 3/4", 90 degree, PVC elbow to the reducer until it is tight to the metal. Note: To assure proper drainage, the fireplace must be installed on a leveled surface. Drain Pan Cat. No. Model Description H4651 DPSS36 Drain Pan (36) H4652 DPSS42 Drain Pan (42) Figure 1 Step 4. Add additional piping to route the drain to an appropriate location. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2006 by LHP P/N 750,213M REV. N/C 05/2006 LHP 1110 West Taft Avenue Orange, CA 92865...
Other models in this manual:Fireplaces - DPSS42 (176.07 kb)