Login:
Votes - 2, Average rating: 4.5 ( )

User manual Lennox Hearth, model MILLIVOLT LMBV-36RMP

Manafacture: Lennox Hearth
File size: 1.04 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


de cat. H8024 lENNOx HEARTH PRODUCTS 1-800-9-lENNOx Nota: La etiqueta en ingles es transparente con texto rojo. Las etiquetas en frances y espanol son negras con texto blanco. DIAGRAmAS DE ETIQUETAS DE SEGURIDAD Hot Fireplace Will Cause Severe Burns Never Allow Children to Touch Glass or other Fire- place Parts WARNING Un foyer chaud peut causer de graves brulures Ne laissez jamais un enfant toucher a la vitre ou a toutes autres parties du foyer AvERTISSEmENT la chimenea caliente causara quemaduras graves Nunca permita que los ninos toquen el vidrio ni otras partes de la chimenea ADvERTENCIA Un foyer chaud peut causerde graves bruluresNe laissez jamais un enfanttoucher a la vitre ou a toutesautres parties du foyer AVERTISSEMENT Hot Fireplace Will CauseSevere BurnsNever Allow Children toTouch Glass or other Fire-place PartsWARNING Figure A Figure B NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 7 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. LENNOX MERIT® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • CARE AND OPERATION INSTRUCTIONSFigure 9 Figure 8 maintenance The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service technician. Proper maintenance and use will require more frequent, less extensive inspections and servicing by the homeowner. Generally, annual inspections should be performed by a qualified service technician. More frequent periodic inspections and cleanings should be performed by the homeowner. Any discrepancies discovered by the homeowner should result in a call to a qualified service technician to effect the repair or correction. Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by whom they should be performed. ImPORTANT: TURN OFF GAS AND ANy ElECTRICAl POWER bEFORE SERvICING THE APPlIANCE. millivolt Appliance Checkout The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top 3/8" (9 mm) at the pilot generator (thermopile) should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports (Figure 9 ). Electronic Appliance Checkout Light the burner, refer to the Lightilng Instructions in this manual. Ensure the ignitor lights the pilot. The pilot flame should engulf the flame rod as shown in Figure 9. With proper care and maintenance, your appliance will provide many years of enjoyment. If you should experience any problem, first refer to the trouble shooting guide in this manual. If problem persists, contact your Lennox distributor. 3/8" Min (9 mm) Hood Pilot Nozzels Ignitor Rod Proper FlameAdjustment Hot Surface Igniter Flame Rod Ground Electrode 3/8 To 1/2 Inch (9 mm to 13 mm) Pilot Nozzle MILLIVOLT ELECTRONIC LENNOX MERITLENNOX MERIT SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • CARE AND OPERATION INSTRUCTIONS maintenance Schedule Annually (Before the onset of the Burning Season) maintenance Task Accomplishing Person Procedure Inspecting/Cleaning Burner, Logs and Controls Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area. Check Flame Patterns and Flame Height Qualified Service Technician Refer to Figure 8 and verify the flame pattern and height displayed bytheapplianceconforms to the picture. Flames must not impinge on the logs. Inspecting/Cleaning Pilot and Burner Qualified Service Technician RefertoFigure9. Removeanysurfacebuild-up on pilot and burner assembly. Wipe the pilot nozzles, ignitor/flame rod and hood. Ensure the pilot flame engulfs the flame sensor as shown. Checking Vent System Qualified Service Technician Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of dislocation of the vent components. Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed in this manual. Replacing Rockwool Ember Materials Homeowner/Qualified Services Technician Remove old ember materials and vacuum the screened rockwool placement area. Place new rockwool as described in this document. Periodically (After the Burning Season) maintenance Task Accomplishing Person Procedure Cleaning Firebox Interior Homeowner Carefully remove logs, Rockwool and volcanic stone ifused. Vacuum outinterior ofthefirebox. Clean firebox walls and log grate. Replace logs, Rockwool and volcanic stone as detailed in this manual. Check Flame Patterns and Flame Height Homeowner Refer to Figure 8 and verify the flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs. Checking Vent System Homeowner Inspect the vent system at the top and at the base (within the firebox) for signs of blockage orobstruction. Look for anysignsof dislocation of the vent components. Cleaning Optional Glass Doors Homeo...

Other models in this manual:
Fireplaces - MILLIVOLT LMBV-36REN (1.04 mb)
Fireplaces - MILLIVOLT LMBV-36RMN (1.04 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category