Login:
Votes - 3, Average rating: 4.7 ( )

User manual Desa Tech, model CGCFTN

Manafacture: Desa Tech
File size: 1.73 mb
File name: c5e891b1-832b-54c4-5db7-536b17ca9bd2.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


causing property damage, personal injury, or Refer to this manual for correct installa loss of life. tion and operational procedures. For as — Do not store or use gasoline or other sistance or additional information con- flammable vapors and liquids in the vicinity of sult a qualified installer, service agency, this or any other appliance. or the gas supplier. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. WARNING: This is an unvented gas• Do not touch any electrical switch; do not use fired heater. It uses air (oxygen) from theany phone in your building. room in which it is installed. Provisions • Immediately call your gas supplier from a for adequate combustion and ventilaneighbor’s phone. Follow the gas supplier’s tion air must be provided. Refer toAir for instructions. Combustion and Ventilationsection on • If you cannot reach your gas supplier, call page 5 of this manual. the fire department. — Installation and service must be performed by a qualified installer, service agency, or the gas supplier. This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer Save this manual for future reference.Save this manual for future reference. 2 2 TABLE OF CONTENTS SAFETY INFORMATION TABLE OF CONTENTS SAFETY INFORMATION ............................................................ 2 LOCAL CODES ........................................................................... 3 PRODUCT IDENTIFICATION ..................................................... 3 PRODUCT FEATURES .............................................................. 4 UNPACKING ............................................................................... 4 ASSEMBLY ................................................................................. 4 AIR FOR COMBUSTION AND VENTILATION ........................... 5 INSTALLATION ........................................................................... 7 OPERATING FIREPLACE ........................................................ 17 INSPECTING BURNER ............................................................ 18 CLEANING AND MAINTENANCE ............................................ 19 TROUBLESHOOTING .............................................................. 20 SPECIFICATIONS .................................................................... 23 REPLACEMENT PARTS .......................................................... 23 SERVICE HINTS....................................................................... 23 TECHNICAL SERVICE ............................................................. 23 ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 24 PARTS CENTRALS .................................................................. 26 OWNER’S REGISTRATION FORM .......................................... 27 ACCESSORIES ........................................................................ 29 WARRANTY INFORMATION ...................................... Back Cover SAFETY INFORMATION WARNINGS WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm. IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added tothe gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace. WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting. WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this fireplace. Due to high temperatures, the appliance should be located out of traffic and away from...

Other models in this manual:
Fireplaces - CGCFTP (1.73 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category