Login:
Votes - 5, Average rating: 4 ( )

User manual Desa Tech, model ELCG 347

Manafacture: Desa Tech
File size: 1.56 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


• As a visual effect - only the flame effect is on, the heater is off. We recommend this mode for warm weather application, when you want the ambiance of a fire, without any heat output. The log set control functions can be accessed in two (2) ways: • Using the control panel buttons, located on the lower right-hand corner of the log set. • Using the multifunction remote control unit. Figure 3 1 2 3 3 2 1 Main Power Button: This button supplies power to all the functions of the log set. The Main power button must be in the ON position, either from the remote or controls on the log set for the functions to work. Heater Control Button: This button controls the heater ON/OFF and 5 temperature modes from Low to High. When the heater is first turned on, it will come on at the lowest room temperature setting. The log set will remember the last heat setting and in later use the heater will start at that setting, unless power to the unit has been interrupted. Each time the Temperature button is pressed, the temperature set point increases, allowing you to adjust the ambient temperature. Flame Control button: This button controls the brightness of the flame effect with settings at High, Medium and Low. When the log set is first turned on, the flame will come on at the highest setting. The log set will remember the last flame setting used and in later use the flame brightness will start at that setting, unless power to the unit has been interrupted. Each time the Flame button is pressed, the flame brightness decreases. The only way to turn off the flame effect completely is to turn off the Main Power button. 10 2 3 1 The infrared remote control relies on a line of sight and must be pointed at the controls of the log set to work. The remote control unit has the controls required to turn ON/OFF both the main power and the heater. If you prefer to use the control buttons on the log set unit itself, they are on the lower right corner of the unit. The layout of the buttons and remote control unit can be seen in Figures 3 and 5, respectively. 1. Plug your log set into a 15-amp, 120-volt power outlet. 2. Turn the power on. Flame will show on the wall behind the log set. 3. Remove plastic tab from inside battery compartment to activate remote control. 4. Point the remote control directly at the control buttons of the log set and use the buttons to operate the log set. Main Power Button: This button supplies power to all the functions of the log set. The main power button must be in the ON position, either from the remote or the controls on the log set for the functions to work. Heater Control Button: This button controls the heater ON/OFF and 5 temperature modes from Low to High. When the heater is first turned on, the heater will come on at the lowest room temperature setting. The log set will remember the last heat setting and in later use the heater will start at that setting, unless power to the unit has been interrupted. Each time the Temperature button is pressed, the temperature set point increases, allowing you to adjust the ambient temperature. Flame Control button: This button controls the brightness of the flame effect with settings at High, Medium and Low. When the log set is first turned on, the flame will come on at the highest setting. The log set will remember the last flame setting used and in later use the flame brightness will start at that setting, unless power to the unit has been interrupted. Each time the Flame button is pressed, the flame brightness decreases. The only way to turn off the flame effect completely is to turn off the Main Power button. The plastic tab inside the battery compartment MUST be removed before remote control will operate. Figure 4 OPERATING INSTRUCTION 1 2 3 Figure 5 (Pull tab) CARE AND MAINTENANCE Before attempting ANY maintenance: 1. Turn off power to the unit. 2. Unplug the power cord from outlet. 3. Let log set cool if it has been operating. Maintenance of Motors: Always disconnect the appliance from the main power supply and allow it to cool before any servicing operation. The motors used on the fan heater and flame blower are pre-lubricated for extended bearing life and require no further lubrication. However, periodic cleaning/vacuuming of the appliance around the air intake and exhaust, as well as the fan heater is recommended. For heavy or continuous use, periodic cleaning must be done more frequently. If the heater blows alternating cold and warm air, check the fan for free movement and for debris restricting air flow. If the fan does not move freely, the unit must be turned off and the fan replaced immediately in order to prevent further damage to the unit. Cleaning: Cleaning of the log set is to be done only with a vacuum cleaner or by using a soft cloth, slightly dampened in water (if needed, a small amount of dish soap can be added to the water) and dried using a clean, dry soft cloth. DO NOT use any abrasive household cleaners as these products will damage the un...

Other models in this manual:
Fireplaces - ELCG 240 (1.56 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category