20012697 33 Radiance Direct Vent Gas Heater Comfort Control Valve System Sequence of Operation with Transmitter Light pilot burner Set manual switch to local or remote Release pilotstat knob. Turn pilotstat knob from PILOT to ON. Did the LED stop blinking? Yes No Move switch from local to remote. Press any key on transmitter. Move switch back to local. Five minute wait period Review LED fail- ure analysis. On Path If the manual switch is set to REMOTE, press the mode button to display “ON”. does transmitter control the main burner and fan? Yes Move switch from manual to remote. Press any key on transmitter. Does transmitter No change levels of flame height, fan speed? Yes Cycle switch once and leave in remote. Press any key on transmitter for recognition operation. Choose Manual or Remote path. Set switch to manual or remote. If manual switch is set to LOCAL, did main burner light and fan turn on? Turn pilotstat knob to PILOT to turn off main burner. Turn pilotstat knob to OFF to turn valve completely off. Local Path Yes Set levels of flame height and fan to “0” to shut off main burner and fan. Turn pilotstat knob to OFF to turn valve completely off. Radiance Direct Vent Gas Heater Auto Path If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter. Does the transmitter display the room and temperture setting? Yes Move switch from LOCAL to REMOTE. Press any key within 30 seconds. If the settings is above room temperture on the No transmitter, does the main valve and fan turn on? Yes If the settings is below room temperture on the No transmitter, does the main valve and fan turn off? Turn pilotstat knob to OFF to turn valve completely off. 20012697 35 3636 Radiance Direct Vent Gas Heater 20012697 Conversion Precautions Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. Fuel Conversion Instructions WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit. CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. ST226 attach gas line 12/8/99 djt PILOT ON OFF PILOT ADJ LOHI Main Gas Line Gas Supply Inlet ST226a Fig. 60 Attach the gas line to the right side of the valve. Conversion Procedure 1. Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 25, Fig. 46) 2. Undo the right and left latches at the top of the glass frame. (Page 25, Fig. 47) 3. Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a counter protected by a towel. 4. Remove the logset from the firebox. Valve Conversion RADVT Series Models 1. Turn control knob to the OFF position, and shut off the gas supply to the valve. 2. Allow the valve to cool to room temperature. 3. Remove the black protection cap by hand. (Fig. 61) 4. Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (Fig. 62), rotate it counterclockwise until it is free and extract it. 5. Check that the screw is clean and if necessary remove dirt. 6. Flip the screw. (Fig. 63) 7. Using the Allen wrench as shown in Figure 64, rotate the screw clockwise and tighten until snug. WARNING: Do not overtighten the screw. Recommended to grip the wrench by the short side. 8. Verify that if the conversion is from NG to LP, the screw must be reassembled with the red o-ring visible. (Fig. 65) .... .... .......... ........................ ........ Figure 61 .... .... .......... ........................ ........ Figure 62 .... .... .......... .................... ........ Figure 63 .... .... .......... ........................ ........ Figure 64 .... .... .... .... LP Configuration Natural Gas Configuration CO141 O-ring configuration 6/07 Red O-ring Visible Red O-ring NOT Visible CO141 Figure 65 9. Replace the black protection cap. WARNING: Check that also the pilot and main burner injectors are appropriate for the gas type. RADVTC Series Models 1. Follow procedure for pilot type 2 to replace pilot orifice. Radiance Direct Vent Gas Heater 2. Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 32, Fig. 57) 3. Remove motor top cap using a standard slotted screwdriver. Depress and turn center plunger until arrow ...
Other models in this manual:Fireplaces - RADVTSG (4.03 mb)
Fireplaces - RADVTVG (4.03 mb)
Fireplaces - RAD- VTBB (4.03 mb)
Fireplaces - RADVTBD (4.03 mb)