Login:
Votes - , Average rating: ( )

User manual Desa, model (V)V36EN

Manafacture: Desa
File size: 4.74 mb
File name: af29e626-f676-d1e4-255f-4810c780d79e.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


In the event of a power outage, you can use this fireplace as a heat source. FRAMING AND FINISHING Figure 4 shows typical framing of this fireplace. Figure 5 shows framing for corner installation. All minimum clearances must be met. For available accessories for this fireplace, see Accessories on page 31. If you are using a separate combustible mantel piece, refer to Figure 6 for proper installation height. You can install noncombustible mantels at any height above the fireplace. Note:Noncombustible mantels may discolor! A B E F G H D C Nailing Tabs 36" Models 42" Models A 35 3/4" 41 5/8" B 15" 21 5/8" C 49 5/8" 58 1/2" D 10 3/8" 13 1/2" E 13 3/4" 16 3/4" F 41" 48" G 41 3/4" 48 3/4" H 68 1/2" 81 1/2" Figure 5 - Framing Clearances for Corner Installation C B A D E F G Top of Louver Opening 3 2 1 4 5 6 7 Wall Ref. Mantel Depth Ref. Mantel from Top of Louver Opening 1 14" (356mm) A 16" (406mm) 2 12" (305mm) B 14" (356mm) 3 10" (254mm) C 12" (305mm) 4 8" (203mm) D 10" (254mm) 5 6" (152mm) E 8" (203mm) 6 4" (101mm) F 6" (152mm) 7 2" (51mm) G 4" (101mm) B A C Vertical Termination D Horizontal Termination 36" Models 42" Models A 36 1/2" 40 1/2" B 41 3/4" 48 3/4" C 27 3/8" 29 1/2" D 24 7/8" 27" Figure 4 - Framing Clearances for Installation Against an Exterior Figure 6 - Clearances for Combustible Mantels Wall For more information, visit more information, visit 6 6 LOCATION OF TERMINATION CAP LOCATION OF TERMINATION CAP Fixed Closed Openable Fixed Closed OpenableV V V V V V X X V X G G J F B B K N H I A N E LD B M C B V VA G G B TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony I = clearance to service regulator vent outlet [*72 inches (1829mm) [*12 inches (305mm) minimum] minimum] B = clearance to window or door that may be opened J = clearance to non-mechanical air supply inlet to building or the [12 inches (305mm) minimum] combustion air inlet to any other fireplace [*12 inches (305mm) C = clearance to permanently closed window [minimum 12 inches minimum] (305mm) recommended to prevent condensation on window] K = clearance to a mechanical air supply inlet [*72 inches (1829mm) D = vertical clearance to ventilated soffit located above the terminal minimum] within a horizontal distance of 24 inches (610mm) from the L = clearance above paved side-walk or a paved driveway located on center-line of the terminal [18 inches (457mm) minimum] public property [*84 inches (2133mm) minimum] E = clearance to unventilated soffit [12 inches (305mm) minimum] M = clearance under veranda, porch, deck [*12 inches (305mm) minimum ] F = clearance to outside corner (see below) N = clearance above a roof shall extend a minimum of 24 inches (610mm) G = clearance to inside corner (see below) above the highest point when it passes through the roof surface and H = *not to be installed above a meter/regulator assembly within any other obstruction within a horizontal distance of 18 inches (457mm) 36 inches (914mm) horizontally from the center-line of the regulator vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow the current National Fuel Gas Code, ANS Z223.1 Note: Local codes or regulations may require different clearances Termination Clearances for Buildings with Combustible and Noncombustible Exteriors Inside Corner Outside Corner Recessed Location V A A = 6" (152mm) V B B = 6" (152mm) Balcony with No Side Wall Balcony with Perpendicular Side Wall V G H G = 12" (305mm) minimum clearance V J Combustible & Noncombustible H = 24" (610mm) J = 20" (508mm) C = Maximum depth of 48" (1219mm) for recessed location D = Minimum width for back wall of recessed location Combustible - 38" (965mm) Noncombustible - 24" (610mm) E = Clearance from corner in recessed location- Combustible - 6" (152mm) Noncombustible - 2" (51mm) C D C Figure 7 - Minimum Clearances for Termination Cap For more information, visit more information, visit VENTING INSTALLATION INSTRUCTIONS Installation Precautions 7 VENTING INSTALLATION INSTRUCTIONS NOTICE: Read these instructions completely before attempting installation. These models are tested and approved for use with DESA International (direct-vent) pipe components and terminations. The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance. These models are approved to be vented either horizontally through an outside wall or vertically throu...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category