Login:
Votes - , Average rating: ( )

User manual New Buck Corporation, model 32

Manafacture: New Buck Corporation
File size: 977.65 kb
File name: ec09e197-42a9-4455-93c3-77cf3af8d2a9.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. Page 17 GAS PRESSURE CHECK Check the inlet pressure to the burner to ensure that it is shown in the table below. NOTE: The pressure check point is located on the right side of the valve facing burner, for SIT Millivolt, and the left side for SIT Modulating. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa). The appliance must be isolated from the gas supply piping system by closing its equipment shut -off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa). VALVE (MILLIVOLT) (SIT MANUAL-MODULATING) MODEL: FP32 FP32 FP32 FP32 GAS Natural Propane Natural Propane Maximum Heat Input 33,000 33,000 33,000 33,000 Minimum Heat Input 23,000 23,000 12,000 13,000 Gas Inlet Pressure Maximum 10.5ins.W.C. 13ins.W.C. 10.5ins.W.C. 9.0ins.W.C. Minimum * 5.0ins.W.C. *11ins.W.C. *5.0ins.W.C. *11ins.W.C. Manifold Pressure Maximum 3.5ins.W.C. 9.0ins.W.C. 3.5ins.W.C. 9.0ins.W.C. Minimum 3.0ins.W.C. 8.2ins.W.C. 2.8ins.W.C. 7.2ins.W.C. NOTE: On initial installation it may be necessary to bleed out air in the gas lines. Do this by holding the control knob and turning the knob to the “PILOT” position for about 30 seconds. To check the regulator pressure, remove the pressure tag plug at the left side of the regulator facing the heater. The pressure should be checked with the heater burning and the control set on high. After measuring the pressure, replace the pressure tap plug, ensuring that there are no leaks. * For the purpose of minimum input adjustment. WARNING This appliance is equipped for (natural or propane) gas. Field conversion is not permitted. Solid fuels shall not be burned in the same fireplace where an unvented room heater has been installed. NOTE: The following label has been provided with this appliance and must be read and then attached to the floor of the fireplace or firebox area beneath the appliance. The label is a peel and stick label. Make sure the area is cleaned before attaching the label to it. “WARNING: This solid-fuel burning fireplace or listed ventless enclosure has been converted for use with an unvented fireplace insert only. A solid-fuel burning fireplace cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fireplace re-approved by the authority having jurisdiction. A ventless firebox enclosure cannot be used with an unvented gas log unless all original parts have been replaced, and the ventless firebox enclosure reapproved by the authority having jurisdiction.” Page 18 LIGHTING INSTRUCTIONS MILLIVOLT VALVE (ITT) FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell around the appliance for gas. Be sure to smell next to the floor because gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS ¦ Do not try to light any appliance. ¦ Do not touch any electrical switch; do not use any phone in your building. ¦ Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. ¦ If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Page 19 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on previous page. 2. Make sure the manual shutoff valve is fully closed. If equipped with thermostat set to the lowest setting. 3. Turn off all electrical power to the appliance. 4. Open access panel door located at bottom front of the appliance. 5. Turn control knob clockwise to the full “OFF” position. ROCKER SWITCH IGNITOR ELECTRODE PILOT 9080706050 ONOFF BEFORE INSTALLING THERMOSTAT REMOVE METAL CONNECTOR PIEZO BURNER PILOT ASS'Y THERMOSTAT ITT VALVE THERMO GEN AUX PRESSTORESETOFF PILOT ON ITTGENERAL CONTROLS PILOTADJ THERMOPILE CONTROL KNOB PILOT BURNER FIGURE: 8 When hooking up a Wall Thermostat to valve, remove the Jumper Bar. Do not remove the existing wires, simply add the wire from the Wall Thermostat to screws (one wire to...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category