Login:
Votes - , Average rating: ( )

User manual Monessen Hearth, model SDVI

Manafacture: Monessen Hearth
File size: 4.14 mb
File name: Lennox_Hearth_SDVI_Installation_506056-01.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


Refer to the National Fuel Gas Code and local zoning and code authorities for details on installation requirements. • Mobile home installations must conform with the Mobile Home Construction and Safety Standard, Title 24 CFR, Part 3280 (in Canada CAN/CSA Z240 MH), or, when such a standard is not applicable, the Standard for Mobile Home Installations, ANSI A225.1 -latest edition. • Must be vented directly to the outside in accordance with the latest edition of the National Fuel Gas Code and must never be attached to a chimney serving a separate solid fuel burning appliance. • Has been certified for use with either natural gas or propane. • Is not for use with solid fuels. • Is approved for sitting rooms and/or bedrooms. Fireplace Requirements These heaters are designed to be installed into an existing masonry fireplace (built to UBC 37 or ULC S628 standards) or factory built solid fuel, wood burning fireplace (listed to UL 127 or ULC S610) only. All exhaust gases must be vented outside the structure. Combustion air is drawn from outside the structure. When installing in a factory built fireplace, the fireplace grate must be removed and the damper must be removed or secured open. If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1-1/2 inches (38 mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be plugged with a non-combustible insulation after the gas supply line has been installed. The installer must mechanically attach themarkingsuppliedwiththegasfireplaceinserttotheinsideofthefirebox of the fireplace into which the gas fireplace insert is installed. IMPORTANT: When installing these appliances into a factory built fireplace or heat-form, the air flow within and around the fireplace shall not be altered by the installation of the insert (i.e. DO NOT BLOCK louvers or cooling air inlet or outlet ports, circulating air chambers in a steel fireplace liner or metal heat circulator). WARNING THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON PRIOR TO RE-USE AS A CONVENTIONAL FIREPLACE. CODES AND APPROVALS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Certification Gas appliances must be tested and certified by a nationally recognized testing and certification laboratory to ANSI (American National Standard Institute) gas appliance safety standards. This insert has been tested and certified by OMNI -Test Laboratories to ANSI Z21.88/CSA 2.33 Standard for Vented Gas Fireplace Heater and CGA 2.17-M91and UL307BGasBurningHeating AppliancesforManufactured (Mobile) Homes in both USA and Canada. It has met all necessary ANSI Standards and is fully certified for installation in any community. If there are any questions or if you need further substantiation either write to or call your LHP dealer. If you have further questions, please contact LHP. Checkalllocalbuildingandsafetycodesbeforeinstallation.Theinstallation instructions and appropriate code requirements must be followed exactly and without compromise. In the absence of local codes the following standards and codes must be followed. The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition (In Canada, the current CAN/CSA-B149.1 installation code). The appliance, when installed, must be electrically grounded and wired in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition, or the Canadian Electrical Code, CSA C22.1 - latest edition. (Massachusetts Approval #G3-0806-6) These appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met: • Install this appliance in accordance with Massachusetts Rules and Regulations 248 C.M.R. Sec. 5.08 2(a) through 2(e). • Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts. • The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length. • The individual manual shut-off must be a T-handle type valve. Massachusetts Horizontal Vent Requirements IntheCommonwealthof Massachusetts,horizontalterminationsinstalled less than seven (7) feet above the finished grade must comply with the following additional requirements: • A hard wired carbon monoxide detector with an alarm and battery back-up must be installed on the floor level where the gas fireplace is installed. The carbon monoxide detector must comply with NFPA 720, be ANSI/UL 2034 listed and be ISA certified. • A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade and be directly in line with the horizontal termination. The sign must read, in print size no less than one-half (1/2) inch in size, GAS VENT DIREC...

Other models in this manual:
Fireplaces - SDVI (4.14 mb)
Fireplaces - SDVI (4.14 mb)
Fireplaces - SDVI (4.14 mb)
Fireplaces - SDVI (4.14 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category