|
manual abstract
Modular Homes & Buildings IMPORTANT -Only individuals having proven expedence with this type ofequipment shouldattemptto performset-up. Proper furnace set-up and adjustment is the responsibility of the retailer/homeowner and is not covered under warranty. FURNACE START-UP CHECK LIST Has roof jack crown been correctly installed? Has furnacegasvalveandburnerorificebeen correctlycon vetted for Propane. gas where applicable? Has furnace gasvalvebeende-rated foraltitudesabove2000 feet where applicable? Is gas line outlet pressure properlyset for fuel type? (naturalgas is 3.5" W.C.; Propane is 10" W.C.) Is cross-overduct installed per home builder and UPG installation instructions? Has furnace been operated througha complete heatingcycle? Has the pilotflame been adjusted properly? (DGPH and DGPA Models) 035-16328-002 Rav. C (0902) 035-16328-002C(0902) Rev. FURNACE SPECIFICATIONS DGAA --AUTOMATIC IGNITION --WITH BUILT-IN COIL CABINET --4 TON -AIC READY MODEL NO, Factor'/Equipped for use with Input/BTUH OutputJBTUH DGAA056BDTA NATURAL GAS 56,000 45,000 DGAA07OBDTA NATURAL GAS 70,000 56,000 DGAAO77BDTA NATURAL GAS 77,000 62,000 DGAAO9OBDTA NATURAL GAS 90,000 72,000 DGPA --STANDING PILOT --WITH BUILT-IN COIL CABINET --3 TON -AIC READY DGPA056ABTA NATURAL GAS 56,000 45,000 DGPA070ABTA NATURAL GAS 70,000 56,000 DGPA077ABTA NATURAL GAS 77,000 62,000 DGPA090ABTA NATURAL GAS 90,000 72,000 DGPH --STANDING PILOT --WITH BUILT-IN COIL CABINET --3 TON -NO AIC CONTROLS DGPHO56ABTA NATURALGAS 56,000 45,000 DGPHO70ABTA NATURALGAS 79,000 66,000 DGPH077ABTA NATURALGAS 77,005 62,000 DGPH09OABTA NATURALGAS 90,000 72,000 DGAH --AUTOMATIC IGNITION --HEATING ONLY --NO COIL CABINET DGAH056BBSA DGAHO77BBSA I NATURALGAS66,09045,006 II NATURAL GAS 77,000 62,000 ELECTRICAL SPECIFICATIONS Electdcal Power Supply 115 Volts -60 Hz-1Phase Breaker or Fuse 15 Arnp Thermostat Circuit 24 Volt -60 Hz -40 VA Nominal Anticipator Setting .50 Gas Valve Inlet 1/2" NFPT 24-314" 19.1/2 ° 24-314" 19-1/2" 76" 5g=1/2" DGAHSeries DGPH, DGPA & DGAA Series FIGURE 1 : Furnace Dimensions Unitary Products Group GENERAL INFORMATION NOTE: The words "Shall" or "Must" indicate a requirement which is essential to satisfactory and safe product performance. The words "Should" or "May" indicate a recommendation or advice which is not essential and not required but which may be useful or helpful. IMPORTANT -These instructions are primarily intended to assist qualified individuals experienced in the proper installation of heating and/or air conditioning appliances. Some local codes require licensed installation service personnel for this type of equipment. Read all instructions carefully before starting the installation. I_WARNINGI Improper installation may damage equipment, can create a shook hazard, and will void the war- ran_ The furnace shall be installed so the electrical components are protected from water The furnace is not to be used for temporary heating of buildings or structures under construction. Do not test the fuel system at more than 14 inches water column after fumace has been con nected to the fuel line. Such testing may void the warren_ Any test run above 14 inches water column may damage the furnace control valve which could cause an explosion, fire, or asphyxi ation. INSTALLATION STANDARDS CODECOMPLIANCE The installer must comply with all local codes and regulations which govern the installation of this appliance. Local codes and regulations shall take precedent over these regulations where applicable. In lieu of local codes, the appliance shall be installe...
Other models in this manual:Electric Heaters - DGAA07OBDTA (821.13 kb)
Electric Heaters - DGAAO77BDTA (821.13 kb)
Electric Heaters - DGAAO9OBDTA (821.13 kb)
Electric Heaters - DGAH056BBSA (821.13 kb)