Login:
Votes - 3, Average rating: 4 ( )

User manual Empire Comfort Systems, model RH-50-6

Manafacture: Empire Comfort Systems
File size: 704.99 kb
File name: d0b5398a-710e-42f7-bad7-200bfcb4911d.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Page 12 12822-2-0903 12822-2-0903 Page 13 PARTS VIEW RH-50 & RH-65 PARTS LIST RH-50C & RH-65C PARTS LIST RH-50C & RH-65C PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. INDEX PART INDEX PART NO. NUMBER DESCRIPTION NO. NUMBER DESCRIPTION 1 11723 Diverter Assembly 18 R-6126 Electrode and Wire Assembly 2 RH-802 Down Draft Shield (RH-50C-1 NAT 19 11712 Pilot Tubing (RH-50C-1) & LPG) 19 11713 Pilot Tubing (RH-65C-1) 2 RH-851 Down Draft Shield (RH-65C-1 NAT 20 RH-457 Air Shutter Bracket & LPG) 21 P-267 Manifold Assembly (RH-50C/CB-1) 3 11724 Draft Diverter Plate21 P-268 Manifold Assembly (RH-65C-1) 4 11719 Casing Top (RH-50C-1) 22 P86-3.7mm Main Burner Orifice (RH-65C-1 Nat) 4 11720 Casing Top (RH-65C-1) 22 P86-3.1mm Main Burner Orifice (RH-50C-1 Nat) 5 11707 Louver (RH-50C-1, 3 Required) 22 P86-2.3mm Main Burner Orifice (RH-65C-1, 4 Required) (RH-65C-1 LPG) 6 11745 Casing Back 22 P86-47 Main Burner Orifice 7 11741 Combustion Chamber Assembly (RH-50C-1 LPG) (RH-50C-1) 23 11746 Valve Bracket 7 8 11742 RH-654 Combustion Chamber Assembly (RH-65C-1) Chamber Shield - Right (RH-50C-1) 24 24 25 R-6101 R-6102 11743 Gas Valve (Nat) Gas Valve (LPG) Control Rod 8 RH-655 Chamber Shield - Right (RH-65C-1) 26 11700 Control Rod Bracket 9 9 10 11 11721 11722 RH-618 RH-625 Casing Side (RH-50C-1) Casing Side (RH-65C-1) Inner Front Bottom Reflector (RH-50C-1) 27 28 28 29 R-6096 11722 11721 RH-653 Knob & Adaptor Set Casing Side (RH-65C-1) Casing Side (RH-50C-1) Chamber Shield - Left 11 RH-660 Bottom Reflector (RH-65C-1) 30 RH-656 Chamber Shield - Rear 12 13 13 14 RH-624 11725 11726 RH-853 Rear Shield Casing Bottom Assembly (RH-50C-1) Casing Bottom Assembly (RH-65C-1) Burner 31 32 Not Shown Not Shown Not Shown R-926 R-2706 742148 742250 R-2707 Cable Assembly Eco Switch Pilot Orifice .011 (Nat) Pilot Orifice .008 (LPG) Junction Block Adaptor/ECO Switch 15 15 11755 15675 Casing Front Assembly (USA) Casing Front Assembly (Canada) Not Shown UH-441 Vent Safety Switch/ECO Hole Cover Plate 16 R-776 Thermocouple 17 R-775L Pilot Burner with Orifice (LPG) 17 R-775N Pilot Burner with Orifice (Nat) USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. Page 14 12822-2-0903 12822-2-0903 Page 15 PARTS VIEW RH-50C & RH-65C Page 16 12822-2-0903 Figure 4 Installing Optional Blower 1. Remove rear shield (2 screws) and bottom reflector (4 screws). (See Figure 1) 2. Align blower cushion with bottom assembly air discharge opening. Foil face side of blower cushion should be placed upward. 3. Align blower housing with blower cushion and use two, #10 x 1/2" (13mm )hex-head screws to attach blower housing to bottom assembly. (See Figure 2) 4. Save bottom reflector and rear shield (removed in Step 1) in the event the blower housing is removed from room heater. Attention! Bottom reflector and rear shield must be attached to bottom assembly whenever the blower housing is removed from the room heater and the room heater is in operation. 5. Remove switch box cover from the switch box by removing the #8 x 1/4" (6mm) hex-head screw. 6. There are two screw holes on the lower back of the combustion chamber. Use only the left screw hole for mounting. 7. With the switch box perpendicular to the combustion chamber, align the round clearance hole on the switch box with the left screw hole on the combustion chamber. (See Figure 3) 8. Attach switch box to the combustion chamber using the #10 x 1/2" (13mm) hex- head screw provided. 9. Attach switch box cover to the switch box by using the #8 x 1/4" (6mm) hex- head screw. (See Figure 4) Figure 1 Figure 2 Figure 3 FRB-3 For Vented Room Heaters Models RH-50-(1, 2, 4, 5, 6) RH-50C-1 RH-65-(1, 2, 4, 5, 6) RH-65C-1 OPTIONAL BLOWER INSTALLATION INSTRUCTIONS Attention: Wiring harness on blower is factory assembled and installed. If wiring harness becomes disassembled use the following steps to reassemble the wiring harness. 1. Attach (1) pin terminal from black (hot) wire, smooth insulation on cord set to (1) socket terminal on fan control assembly. 2. Attach (1) pin terminal from black (neutral) wire, ribbed insulation on cord set to (1) socket terminal from white (neutral) wire on motor. 3. Attach (1) pin terminal on fan control assembly to (1) socket terminal from black (hot) wire on motor. 4. Attach green ground wire beneath one of the #10 x 1/2" (13mm) screws on the blower housing. Fan Control The automatic fan control is located in the switch box. The switch box is attached to the front of the blower assembly. The switch box is adjacent to the combustion chamber. The fan control is a non-adjustable automatic type. The fan control will require between 5 and 10 minutes of main burner operation before the fan control "closes" and activates the blower. The blower will continue to run between 5 and 10 minutes after the main burner shuts off, before the fan control "opens" and deactivates the blower. Index Part No. No. Description 1 11...

Other models in this manual:
Electric Heaters - RH-50C-1 (704.99 kb)
Electric Heaters - RH-50C-1 (704.99 kb)
Electric Heaters - RH-65-6 (704.99 kb)
Electric Heaters - RH-65C-1 (704.99 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category