Login:
Votes - , Average rating: ( )

User manual Enerco, model HS35FA

Manafacture: Enerco
File size: 98.21 kb
File name: fed18825-0138-4c82-82ee-cefe90b21534.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


Do not use your telephone. • Get everyone out of the building and away from the area immediately. • Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply valve located at the meter if you use natural gas. • Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas. • Use your neighbor’s phone and call your fuel gas supplier and your fire department. Do not re-enter the building or area. • Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier. • FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you. ODOR FADING - NO ODOR DETECTED • Some people cannot smell well. Some people cannot smell the odor of the man-made chemical added to propane (LP) or natural gas. You must determine if you can smell the odorant in these fuel gases. • Learn to recognize the odor of propane (LP) gas and natural gas. Local propane (LP) gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor. • Smoking can decrease your ability to smell. Being around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor. • The odorant in propane (LP) gas and natural gas is colorless and the intensity of its odor can fade under some circumstances. • If there is an underground leak, the movement of gas through the soil can filter the odorant. • Propane (LP) gas odor may differ in intensity at different levels. Since Propane (LP) gas is heavier than air, there may be more odor at lower levels. • Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously. ATTENTION - CRITICAL POINTS TO REMEMBER! • Propane (LP) gas has a distinctive odor. Learn to recognize these odors. (Reference Fuel Gas Odor and Odor Fading sections above. • Even If you are not property trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of propane (LP) gas and natural gas. • If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system. • A periodic sniff test around the heater or at the heater’s joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT! Enerco Group, Inc. | Forced Air Propane Construction Heater 4 Operating Instructions and Owner’s Manual OPERATING INSTRUCTIONS PREPARING FOR OPERATION OPERATING INSTRUCTIONS PREPARING FOR OPERATION . Check the heater for possible shipping damage. If any is found, immediately notify the factory. 2. Follow all of the "Precautions". 3. Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinder's valve outlet and securely tighten with a wrench. 4. Connect the hose to the heater by rotating the hose fitting clockwise. 5. Securely tighten all gas connections. 6. Open the cylinder's gas valve and check all gas connections with a soap and water solution. DO NOT USE A FLAME. 7. Connect power cord to well-grounded 115V, 60 Hz, 1O source of power. 8. When using an extension cord, make certain that it is a 3-wire (grounded) cord of proper wire size, minimum length of 6 ft (1.83m). START 1. THE HEATER POWER CORD MUST BE CONNECTED TO A GROUNDED 115V, 60HZ, 1O POWER SOURCE BEFORE HEATER IGNITION and always allow heater fan (blower) to run for 20 seconds to purge fuel. 2. Open propane supply valve on propane tank slowly. Note: If not opened slowly, excess-flow check valve on propane tank will stop gas flow. If this happens, close propane supply valve and open again slowly. Wait 15 seconds before Step 3. 3. Push and hold automatic control valve button. Push piezo ignitor button repeatedly until the burner lights. 4. After the burner lights, keep the gas valve button depressed for 30 seconds then release and the heater will continue to operate. WARNING: Be sure motor and fan are running before pushing in automatic control valve button. Flames could flash outside heater or internal damage to heater may result if motor and fan are not running. STOP 1. Securely close valve on the propane cylinder. 2. Continue to operate heater until all fuel in the hose has burned. 3. Unplug the power cord. CAUTION: Always shut off fuel supply before disconnecting electrical power. RESTART AFTER SAFETY ...

Other models in this manual:
Electric Heaters - MH35FA (98.21 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category