Login:
Votes - 3, Average rating: 4.3 ( )

User manual Enerco, model HS180ID

Manafacture: Enerco
File size: 86.53 kb
File name: 07fd89ed-c0f9-420e-ac5d-ae196faf40cc.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


3 INSTALLATION INSTRUCTIONS ................................................... 3 INSTRUCTIONS FOR USE ............................................................. 3 MAINTENANCE ........................................................................... 4 TROUBLESHOOTING ................................................................... 5 ENERCO GROUP, INC. |Indirect Fired Portable Heater 2 Operating Instructions and Owner’s Manual SPECIFICATIONS MODEL # .............................. 180 ..................... 300 Thermal power (BTU/hr) ........ 181,000 ............... 289,000 Air Flow Rating (ft./min) ....... 1475 .................... 2650 Oil Consumption (gal/hr).......1.29.....................2.06 Fuel Nozzle ............................. 1.00 60° H ........... 1.50 80° W Efficiency (%) ........................ 87.1 ..................... 88.5 Noise Level at 2m (dB(A)) ...... 73 ....................... 73 Voltage (V) ............................ 110V 60Hz 1ph .... 110V 60Hz 1ph Electrical Power (W) ............... 460 ..................... 800 Current Rating (A) ................. 7.0 ....................... 12.0 Weight (lb) ............................. 167 ...................... 267 Length (in) ............................ 55 ........................ 66 Width (in) ............................... 24 ........................ 27 Height (in).............................. 31........................ 37 Flue Diameter (in) .................. 6 ......................... 6 Tank Capacity (gal) ................ 14 ........................ 26 Fuel Pressure (psi) .................. 175 ...................... 175 Air Lock Setting ..................... 2 ......................... 5.5 APPLIANCE DESCRIPTION Mobile space heater with: • closed combustion chamber and gas exhaust duct (indirectfired models) • open combustion chamber (direct-fired models) INSTALLATION INSTRUCTIONS General instructions • The heater must be operated only by properly trained personnel. The manufacturer’s instructions must be followed. • The heater must be installed and operated so that people are not exposed to dangers deriving from exhaust gases, from the hot air flow and in such a way that no fire risks exist. • It is forbidden to install the heater in the surroundings of flammable materials, combustible products, or in places where explosion risk exist. • When the heater is used in a closed room, ensure a minimum volume of 28,300 ft. for the HS180ID model and 53,000 ft. for the HS300ID model and a continuous natural air circulation through windows and doors. For a good combustion, provide approximately 47 cfm air flow from outside. • For the use of the heater the general and special fire safety regulations in force in all fields of applications must be followed. In any case the following minimum safety clearances from materials or objects in the surroundings of the heater must be ensured: Clearances: Sides: 2.5 ft Air inlet: 2.5 ft Top: 6 ft Air outlet: 12 ft • Floors and ceilings must be made of fireproof materials in the room where the heater is operated. • The air inlet and outlet must never be blocked for any reason. • Install the heater on a flat, level floor in a steady position. • It is forbidden to connect direct-fired heaters to air ducts. Maintenance and checks • Depending on the operational conditions, usually every year, the heater should be checked by qualified personnel. • Prior to start-up, the user must check for any evident noncompliance with rules of use, safety and protection. INSTRUCTIONS FOR USE Start-up • The heater is factory set for operation without room thermostat. • If operation with room (remote) thermostat is desired, remove the socket cover (Fig.1, No.1) and insert the thermostat plug into the socket. • Fill the tank with proper fuel. 1 2 3 4 Figure 1 • Connect the supply plug to a 110V ~ 60 Hz single phase earthed socket. The green lamp indicates that the heater is powered. • WARNING: THE APPLIANCE MUST BE GROUNDED ENERCO GROUP, INC. |Indirect Fired Portable Heater 3 Operating Instructions and Owner’s Manual • Indirect fired heaters: connect the heater to a chimney or to a exhaust duct. To get a proper draft (at least .04 in WC) in the chimney the exhaust gas path must rise. Avoid any elbows and bends in the first part of the exhaust ducts for at least 10 ft. For operation of heater in closed rooms without flue refer to the instructions for installation (par. 4) • If a room thermostat is used, set maximum temperature on it. • Turn switch to position “ON” • Set the desired temperature on room thermostat. min 13 ft max 33 ft min 16 ft min 10 ft min 15 ft WARNING! Heaters equipped with heated nozzle do not start immediately or may stop for some seconds after start. This is normal and should not be considered a faulty condition. Reset after lockout and Reset of safety thermostat • The heater is equipped with a Reset pushbutton. When the heater locks out, the red lamp on the pushbutton (fig.1, No.2) lights up. In th...

Other models in this manual:
Electric Heaters - HS300ID (86.53 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category