manual abstract
Above information may change without notice. Accurate specifications can can be found on the name plate located on the unit. 2. When the unit is restarted after it was stopped, it can automatically resume in its most latest running mode, and the outdoor unit starts a little bit later. Do not operate unit if outside temperature range as shown below, or you could damage compresssor and void the warranty Working temperature range Indoor side DB/WB(°C) Outdoor side DB/WB(°C) Maximum cooling 32/23 43/26 Minimum cooling 21/15 21/Maximum heating 27/24/ 18 Minimum heating 20/- 5/-6 12 INST ALLA TION SETUP DIAGRAM INST ALLA TION SETUP DIAGRAM Space to the ceiling Space to the wall Space to the wall Insulation tapeAir outlet side 15cm or more 300cm or more 15cm or more 15cm or more 200cm or more IMPORT ANT NOTES Space to the floor • The installation must be done by trained and qualified service personnel with reliability according to this manual. • It is important to have your mini-split air conditioner installed by a Sunrise Tradex Corp. certified installer for your warranty to be valid. A mini-split air conditioner installed by a technician other than a Sunrise Tradex Corp. certified installer will void the warranty. Space to the cover Air intake side Space to the wall Space to the wall30cm or more 200cm or more 50cm or more 30cm or more 50cm or more 288 440 13 INSTALLATION LOCATION INDOOR UNIT 1. The inlet and outlet should not be covered so that the outflow air can reach all parts of the room. 2. Install in a location where is permitting easy connection with the outdoor unit. 3. A location from which the condensation water can be drained out conveniently. 4. Avoid a location where there is heat source, high humidity or inflammable gas. 5. Install in a location where is strong enough to withstand the full weight and vibration of the unit. 6. Be sure that the installation conforms to the installation dimension diagram. 7. Be sure to leave enough space to allow access for routine maintenance. 8. Install in a location where is a least 1 m (39-3/8”) from other electric appliances such as television, audio device, etc. 9. Select location where is easy to remove and clean the filter. OUTDOOR UNIT 1. Select location from which noise and outflow air emitted by unit will not inconvenience neighbors. 2. Select location where there should be sufficient ventilation. 3. The inlet and outlet should not be covered. 4. The location should be able to withstand the full weight and vibration of the outdoor unit. 5. There should be no danger of flammable gas or corrosive gas leaks. 6. Be sure that the installation conforms to the installation dimension diagram. 7. Please verify with your local authority if the installation of this unit is permitted. 14 Wrenched Bent Wrenched Bent INSTALLATION INSTRUCTIONS INSTALL THE REAR PANEL 50 mm (2”) 50 mm (2”) Right piping hole 1. Always mount the rear panel horizontally. 2. Fix the rear panel on the selected location with screws supplied with the unit. 3. Be sure that the rear panel has been fixed firmly enough to withstand the weight of an Left piping adult of 60 kg (132.3 lbs.), furthermore, the (Fig.2) hole weight should be evenly shared by each screw. INSTALL THE DRAIN HOSE 1. For a proper draining, the drain hose should be placed at a downward slant. Flooded 2. Do not wrench or bend the drain hose or flood its end in water. 3. The extended drainage pipe in the room should be wrapped with the insulating materials. INSTALL THE PIPING HOLE 1. Make the piping hole 50 mm (2”) in the wall at a slight downward slant to the outdoor side. The center of the hole should be determined refer to Fig.2. 2. Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole. INSTALL THE CONNECTION PIPES Connect the connection pipes with the relevant union pipes of the indoor unit of the indoor unit and tighten the flare nut of the connection pipes. NOTE: • Connect the connection pipes with the indoor unit firstly and the outdoor unit secondly. • Be careful in bending the connection pipes, or you will damage the pipes. • If the tightening torque is too big in tightening the flare nuts, leakage will happen. ELECTRICAL WIRING Note: Only an electrician can install the electrical circuit. 1. Open the surface panel. 2. Remove the wiring cover. 3. Route the power connection cord from the back of the indoor unit and pull it toward the front through the wiring hole for connection. 4. Connect as shown on diagram. 5. Reassemble the wiring cover. 15 16 INSTALLATION INSTRUCTIONS ELECTRICAL WIRING - INDOOR UNIT *Only an electrician must do the connection of this unit. Note: The power of indoor unit is supplied by the outdoor unit.The outside disconnect switch must be installed between electrical panel and condensing unit. Operation procedures: 1. Open the surface panel. 2. Open the cover and cover plate of electric box. (Right figure). 3. Remove the ...
Other models in this manual:Electric Heaters - 13-05020 (697.65 kb)