The pilot flame should surround at least the top 3/8” of the powerpile (pilot generator) or flame sensor (see Figure 8). The pilot is unregulated so it will be operating at inlet line pressure (maximum 7” w.c. for Natural Gas and 11” w.c. for Propane Gas). To decrease the pilot flame, turn the screw clockwise (approximately six full turns to bottom of pilot FIGURE 8-B light channel) until you produce sufficient flame at the minimum noise level. PILOT FLAME ADJUSTMENT PILOT FLAME SHOULD ENVELOP 3/8 TO . INCH OF THE TIP OF THE GENERATOR. Page 9 3/8” TO 1/2” STANDING PILOT 3/8” TO 1/2” I.I.D. PILOT FIGURE 8-A CF353C, CF354C, CF503C, CF504C, CF653C, CF654C - STANDING PILOT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot, which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. LIGHTING INSTRUCTIONS 1. STOP! Read the information on the safety label. 2. Set thermostat to lowest setting. 3. Turn off all electric power to the appliance. 4. Remove cabinet door. 5. Push in gas control lever slightly and slide right to “OFF”. MAX. (HIGH) Gas Control PRESSURE REGULATOR Lever NOTE: Lever cannot be moved to “OFF” unless it is pushed in slightly. Do not force. STEP PRESSURE REGULATOR 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the information on the safety label. If you don’t smell gas, go to the next step. 7. Locate red piezo ignitor button. Locate pilot. (Follow metal pilot tube from gas control). OUTLET (MANIFOLD)PRESSURE TAP PILOT BURNER The pilot is located on the side of the burner 8. Slide gas control lever left to “SET” and hold. Immediately begin a series of pushing and releasing the red piezo ignitor button, while observing the pilot. Continue to spark until pilot is lit. Continue to hold the gas control lever to “SET” for about one (1) minute after the pilot is lit. Release the gas control lever and it will return to “PILOT”. Pilot should remain lit. If pilot goes out, repeat steps 5 thru 8. • If gas control lever does not return to “PILOT” when released, STOP and immediately call your service technician or gas supplier. • If the pilot will not stay lit after several tries, slide the gas control lever to “OFF” and call your service technician or gas supplier. 9. Slide gas control lever left to “ON”. 10. Replace cabinet. 11. Turn on all electric to the appliance. 12. Set thermostat to desired setting. TO TURN OFF GAS TO APPLIANCE 4. Push in gas control lever slightly and slide right 1. Turn thermostat to lowest setting. to “OFF”. Do not force. 2. Turn off all electric power to the appliance if service is 5. Replace cabinet door. to be performed. 3. Remove cabinet door. Page 10 CF357C, CF358C, CF557C, CF558C -I.I.D. PILOT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. OUTLET (MANIFOLD) PRESSURE TAP MAXIMUM (HIGH) PRESSURE REGULATOR NOTE: GAS CONTROL Lever LEVER cannot be OUTLET (MANIFOLD) PRESSURE TAP NOTE: Lever moved to “OFF” unless it is pushed in cannot be slightly. moved to “OFF” unless Do not it is pushed in force. slightly. Do not 9. STEP PRESSURE REGULATOR force. Replace cabinet door. 10. Turn on all electric power to the appliance. 11. Set thermostat to desired setting. 12. If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your service technician or gas supplier. STEP PRESSURE REGULATOR TO TURN OFF GAS TO APPLIANCE 1. Turn thermostat to it’s lowest setting. 4. Push in gas control lever slightly and slide right to 2. Turn off all electric power to the appliance if “OFF”. Do not force. service is to be performed. 5. Replace cabinet door. 3. Remove cabinet door. A. This appliance is equipped with an ignition...

Other models in this manual:
Electric Heaters - CF354C-R (276.49 kb)
Electric Heaters - CF654C-R (276.49 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category