manual abstract
STEP 4. Attach floor base to bottom of heater using four #8 screws (provided). NOTE: Floor bases are for use on VFM10, VFT10, VFM20, VFT-20, VFM30 and VFT30 only. The VFM6 Series has no base and is not approved for use with one. HEATER Make sure this cut-out faces back of heater. FIGURE 3 Page 9 GAS CONNECTION STEP 1. Make the gas connection between the manual shut off valve and regulator located inside heater cabinet. Hold regulator when tightening connection to prevent damage to regulator and internal tubing. See Figure 5 for completed installation. NOTE: All piping and connection must be checked for leaks by the installer. If connections are not exposed, a pressure test must be run. The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of . psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than . psig (3.5kPa). Internal Regulator Outside Reg. (Supplied) Supplied by Gas Co. Manual Shut Off Union Drip Leg 1/8” NPT Plug GAS PIPING WITH VF-FSK KIT FIGURE 5 FIGURE 5A Manual Cut off Valve 1/8” NPT Pressure Plug Drip Leg Page 10 VFM63, VFM103 - NATURAL GAS VFM64, VFM104 -L.P. GAS FOR YOUR SAFETY READ BEFORE LIGHT WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted by • If you cannot reach your gas supplier, call the fire hand. When lighting the pilot, follow these department. instructions exactly. C. Use only your hand to push in or turn the gas control B. BEFORE LIGHTING smell all around the appliance knob. Never use tools. If the knob will not push in or area for gas. Be sure to smell next to the floor turn by hand, don’t try to repair it, call a qualified because some gas is heavier than air and will settle service technician. Force or attempted repair may on the floor.result in a fire or explosion. WHAT TO DO IF YOU SMELL GAS: D. Do not use this appliance if any part has been under • Do not try to light any appliance. water. Immediately call a qualified service technician • Do not touch any electric switch, do not use any to inspect the appliance and to replace any part of the phone in your building. control system and any gas control which has been • Immediately call your gas supplier from a under water. neighbor’s phone. Follow the gas supplier’s instructions. LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this label. 2. Depress gas control knob slightly and turn clockwise to “OFF”. 3. Turn off all electric power to the appliance. 7. Turn gas control knob counterclockwise to Gas “PILOT”. Control 8. Depress gas control knob and hold in. Immediately Knob begin alternately pushing and releasing piezo ignitor button, observing pilot, until pilot is lit. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release the gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 2 thru 7. NOTE: Knob can not be turned from “PILOT” to • If knob does not pop up when released, STOP and “OFF” unless knob is depressed slightly. Do not force. immediately call your service technician or gas supplier. 4. Wait five (5) minutes to clear out any gas. Then smell • If the pilot will not stay lit after several tries, turn the for gas, including near the floor. If you smell gas, gas control knob to “OFF” and call your service STOP! Follow “B” in the safety information above technician or gas supplier. on this label. If you don’t smell gas, go to the next 9. Turn gas control knob counterclockwise to step. “ON”. 5. Locate pilot in the cut-out below the burner. 6. Locate pi...
Other models in this manual:Electric Heaters - VFM103 (416.25 kb)
Electric Heaters - VFM104 (416.25 kb)
Electric Heaters - VFM203 (416.25 kb)
Electric Heaters - VFM204 (416.25 kb)