Manafacture: Bryant
File size: 160.59 kb
File name:
|
manual abstract
Dehumidistat Control — Allows the user to select the relative humidity level at which the unit would change fan speed for dehumidification in the winter months. Continuous Mode — If the relative humidity inside the building is lower than selected, air exchange occurs with the outside at low speed. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures continuous air exchange for constant air quality. Intermittent Mode — If the relative humidity inside the building is lower than selected, no air exchange occurs and the system turns off. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures minimum air exchange level when the building is unoccupied to minimize operating costs. Circulation Mode — If the relative humidity inside the building is lower than selected, the ambient air would be circulated and filtered at high speed. If the relative humidity inside the house is higher than selected, air exchange would occur with the outside at high speed. Ensures continuous movement and filtration of air for maximum comfort. Available with automatic control only. AUTOMATIC DEFROST CYCLE FEATURES All models offer a non-electric defrost cycle feature which prevents frost and ice buildup within the heat recovery core. When the outside air temperature falls below 23°F (–5°C) it is electronically sensed and the dampers close the outside air ports. This allows warm indoor air to recirculate within the heat recovery core. The frequency of this cycle increases as the outside air temperature decreases. MODEL 23°F TO 55°F (–5°C TO –15°C) 4°F TO –17°F (–15.6°C TO –27.3°C) BELOW –18°F (–27.8°C) DEFROST* EXCHANGE† DEFROST* EXCHANGE† DEFROST* EXCHANGE† HRVBBLHU 6 Minutes 60 Minutes 6 Minutes 32 Minutes 6 Minutes 20 Minutes HRVBBSVU 6 Minutes 60 Minutes 6 Minutes 32 Minutes 6 Minutes 20 Minutes HRVBBLVU 6 Minutes 60 Minutes 6 Minutes 32 Minutes 6 Minutes 20 Minutes * All defrost times are in the standard mode (as shipped) † Time between defrost when within specified temperature range —4— DIMENSIONS —5— 23/ 16" ) (56.24 PLCS 1" ) (25.42 PLCS 20" (508.0) 301/ 4" (768.3) A B43/4"(120.6) DC4312 15"(381.0) G25/ 16"(58.7)181/8" (460.4)167/ 8" (428.6) EF57/8" DIA(149.2)4PLCS NOTES: 1. FRESH AIR FROM OUTSIDE2. FRESH AIR FROM HRV TO HOUSE3. STALE AIR FROM HOUSE TO HR V4. STALE AIR FROM HR TO OUTSIDE A98002 MODEL NO. A B C D E F G in. mm in. mm in. mm in. mm in. mm in. mm in. mm HRVBBLHU1150 15-1/8 384.2 4-1/16 104 5/58 143.3 14-1/2 368.9 10-3/8 288.9 4-3/8 111.3 7-3/4 196.9 HRVBBLHU1250 19 483 5-13/16 147.7 5-1/16 128.1 14-1/2 368.9 11-3/16 283.9 4-3/8 111.3 10-1/16 255.6 5 3 . 4.[146.0] D 2 27 .[685.8] 22 1 / 16 .[560.4] 1 .[25.4]2 PLCS 15 11 . 16 .[398.5] E 3 14 1 15 . 16 .[23.8] 3 3 . 16 .[81.0] 4 9 . 16 .[115.9)] F DIA2 PLCS 19 3 .4.[501.7] 5 7 .8. DIA[149.2]2 PLCS WALLCONTROLWIRING3 .8. DIA[9.5] A G DRAINS11 . 16 . DIA. [17.5]2 PLCS B C 2 3 . 16 .[55.6]4 PLCS POWERCORD NOTES:1. FRESH AIR FROM OUTSIDE TO HRV2. FRESH AIR FROM HRV TO HOUSE3. STALE AIR FROM HOUSE TO HRV4. STALE AIR FROM HRV TO OUTSIDE DIMENSIONS (continued) A98003 MODEL NO. A B C D E F G in. mm in. mm in. mm in. mm in. mm in. mm in. mm HRVBBSVU1150 18-1/2 469.9 4-11/16 119.1 13-5/16 388.2 15-7/16 392.1 13-9/16 344.5 5-7/8 149.2 19-15/16 506.2 HRVBBSVU1200 24-1/2 622.2 8-3/16 208.0 19-5/16 490.6 14-9/16 369.9 16-15/16 430.2 6-7/8 174.6 19-15/16 506.2 5 3 . 4.[146.0] D 2 27 .[685.8] 22 1 / 16 .[560.4] 1 .[25.4]2 PLCS 15 11 . 16 .[398.5] E 3 14 1 15 . 16 .[23.8] 3 3 . 16 .[81.0] 4 9 . 16 .[115.9)] F DIA2 PLCS 19 3 .4.[501.7] 5 7 .8. DIA[149.2]2 PLCS WALLCONTROLWIRING3 .8. DIA[9.5] A G DRAINS11 . 16 . DIA. [17.5]2 PLCS B C 2 3 . 16 .[55.6]4 PLCS POWERCORD NOTES:1. FRESH AIR FROM OUTSIDE TO HRV2. FRESH AIR FROM HRV TO HOUSE3. STALE AIR FROM HOUSE TO HRV4. STALE AIR FROM HRV TO OUTSIDE DIMENSIONS (continued) A98003 MODEL NO. A B C D E F G in. mm in. mm in. mm in. mm in. mm in. mm in. mm HRVBBSVU1150 18-1/2 469.9 4-11/16 119.1 13-5/16 388.2 15-7/16 392.1 13-9/16 344.5 5-7/8 149.2 19-15/16 506.2 HRVBBSVU1200 24-1/2 622.2 8-3/16 208.0 19-5/16 490.6 14-9/16 369.9 16-15/16 430.2 6-7/8 174.6 19-15/16 506.2 —6— DIMENSIONS (continued) —7— 17 9 . 16 .[446.9] 4 3 . 4.[120.6] 8 1 .8 . DIA[206.4]2 PLCS 5 13 . 16 .[147.6] 5 7 .8 . DIA[148.2]2 PLCS 6 15 . 16 .[176.2] 7 1 .8.[181.0] 18 5 . 16 .[465.1] 2 3 . 16 .[55.6]2 PLCS12 3 .4 .[323.9] 23 15 . 16 .[608.0] 43 .(1092.2) 24 1 . 16 .[611.2] 1 1 . 2.[38.1]2 PLCS 22 3 .8.[568.3] 41 .[1041.4] 1 . [ 25.4]2 PLCS 15 1 .2 .[393.7]3 1 2 4 NOTES:1. FRESH AIR FROM OUTSIDE TO HRV2. FRESH AIR FROM HRV TO HOUSE3. STALE AIR FROM HOUSE TO HRV4. STALE AIR FROM HRV TO OUTSIDE POWERCORD WALLCONTROLWIRING3. 8. DIA [9.5] DRAIN 11. 16 . DIA. ] [17.519 1. 16 . 2 PLCS [484.2] 8 3. 16 . [208.0] 7 3. 16 . A98001 [182.6] HRVBBLVU1200 or HRVBBLVU1330 PHYSICAL DATA MODEL DESCRIPTION CONVENTIONAL COMPACT HIGH EFFICIENCY Model No....
Other models in this manual:Electric Heaters - HRVBBLHU (160.59 kb)
Electric Heaters - HRVBBSVC (160.59 kb)