Login:
Votes - 4, Average rating: 5 ( )

User manual Cadet, model EPA1500/3

Manafacture: Cadet
File size: 480.53 kb
File name: 1011.pdf
Language of manual:enes
Free link for this manual available at the bottom of the page



manual abstract


2. DO NOT operate the heater unless it is level and the mounting feet and front cover are in place. 3. Do not place heater against paperboard or low-density fiberboard surfaces. 4. Do not place heater below or above an electrical convenience receptacle. 5. The chemical properties of some synthetic fibers used in draperies and furniture may cause fading when exposed to any heat, even at low temperatures. Maintain a 12-inch minimum clearance in front and above the heater with a 6-inch minimum on each side. Draperies in front of heater will obstruct heat. Cadet cannot be responsible should discoloration occur. 6. WARNING Overheating or fire may occur. DO NOT place the heater behind doors. 7. WARNING Overheating or fire may occur. DO NOT operate without legs attached. 8. WARNING Fire or explosion may occur. DO NOT place heater in any area where combustible vapors, gases, liquids, or excessive lint or dust are present. 9. WARNING Risk of Electrical Shock. Unplug heater before removing cover or performing any maintenance. 10. WARNING Risk of Fire. Heater must be kept clear of all obstructions: maintain a 12-inch minimum clearance in front and above the heater with a 6-inch minimum on each side. Heaters must be kept clean of lint, dirt and debris. (See Maintenance Instructions) 11. WARNING! Element filled with heat transfer fluid containing 20% Ethylene Glycol and 80% water. In the unlikely event of leakage, if consumed, call your local poison control center or seek medical attention immediately. SAVE THESE INSTRUCTIONS TEL: 360-693-2505 Fax: 360-694-6939 P.O. Box 1675 Vancouver, WA 98668-1675 READ ALL INSTRUCTIONS AND SAFETY INFORMATION This heater is a major electrical appliance and requires adequate electrical connections for safe use. Plug the heater directly into a wall or floor receptacle when possible. If an extension cord is required, use only a heavy duty cord rated for 15 amps minimum. No other major electrical appliance should be operating on the same outlet circuit. WARNING! Risk of Fire. Heater must be kept clear of all obstructions: 12inch minimum clearance in front and above the heater with a 6-inch minimum on each side. WARNING! Risk of Electrical Shock. Unplug the unit before performing any maintenance on heater. Failure to do so could result in serious injury or death! Operation Instructions PLACEMENT: For best results, place the Softheat baseboard heater under a window, along an outside wall, or as close as possible to an outside door. STEP 1 HEATER INSPECTION Carefully lift up and pull front cover forward from the bottom (See Figure 1). Thoroughly inspect your heater for any shipping or handling damage and remove any paper or packaging material found inside the heater. If there is any indication that fluid has leaked, return the damaged heater to original purchase location. Figure 1. STEP 2 REPLACING FRONT COVER Place the hooks at each end of the front panel into the vertical slots located at each end of the heater. Push the cover back against the heater at the top until flush, then push downward on the cover. Cover should lock firmly into place and MUST be flush with the front before operating. STEP 3 ASSEMBLY The support feet must be securely attached to the heater as shown in Figure 1 BEFORE operating the heater. Two plastic support feet and four mounting screws are provided. HEATER OPERATION Notice: This heater is a major electrical appliance and requires adequate electrical connections for safe use. Plug the heater directly into a wall or floor receptacle when possible. If an extension cord is required, use only a heavy duty cord rated for 15 amps minimum . No other major electrical appliance should be operating on the same circuit. How To Operate Your Heater NOTE: Before operating heater, HEATER INSPECTIONSteps 1 through 3 must be completed: 1) Plug the electrical cord into a 120 volt (AC) outlet. The plug should fit tightly into the receptacle for a proper electrical connection. 2) Rotate the thermostat control knob clockwise until the light illuminates, indicating the heating element is on. Model EPA1500/3 multi-watt uni...

Other models in this manual:
Electric Heaters - EPA1000 (480.53 kb)
Electric Heaters - EPA750 (480.53 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category