manual abstract


Transfer Transfers from utility to standby supply occurs after standby voltage is above set levels. Minimum engine run time is 4 minutes after transfer. Utility Pickup Voltage pickup level is 80 percent of nominal voltage. Retransfer Retransfer from standby to utility supply 10 seconds after utility voltage supply is above pickup level. Engine Cool Down Engine will run for 60 seconds after retransfer. Specifications UL® 1008 Listed Transfer Switch Model 01917 Enclosure. . . . . . . . . . . . . . . . . . . NEMA 1 Maximum Load/Circuit: from Load Center . . . . . . . . . . 50 Amps Rated ACVoltage. . . . . . . . . . . . . 250 Volts Poles . . . . . . . . . . . . . . . . . . . . . . 2 Frequency . . . . . . . . . . . . . . . . . . 50/60 Hz Fault Current Rating . . . . . . . . . . 5,000 RMS Symmetrical Amperes Weight. . . . . . . . . . . . . . . . . . . . . 27 lbs. Model 01918 Enclosure. . . . . . . . . . . . . . . . . . . NEMA 3R Maximum Load/Circuit: from Load Center . . . . . . . . . . 50 Amps Rated ACVoltage. . . . . . . . . . . . . 250 Volts Poles . . . . . . . . . . . . . . . . . . . . . . 2 Frequency . . . . . . . . . . . . . . . . . . 50/60 Hz Fault Current Rating . . . . . . . . . . 5,000 RMS Symmetrical Amperes Weight. . . . . . . . . . . . . . . . . . . . . 34 lbs. When Calling the Factory Before contacting Briggs and Stratton Power Products regarding service or repair of this transfer switch, obtain the Model Number and Serial Number from the unit data decal located on or inside the case. To contact Briggs and Stratton Power Products call 1-800-743-4115, between 8:00 AM and 5:00 PM CT. 9 Briggs & Stratton Power Products Automatic Transfer Switch Installation and Owner’s Manual NOTES 10 Briggs & Stratton Power Products Automatic Transfer Switch Installation and Owner’s Manual TROUBLESHOOTING Problem Cause Correction Automatic transfer switch does not transfer to generator 1. Generator breaker open. 2. Generator voltage not acceptable. 1. Reset generator circuit breaker. 2. Refer to generator manual. Automatic transfer switch does not transfer to utility 1. Main distribution panel breaker open. 2. Utility voltage not acceptable. 1. Reset main distribution panel breaker. 2. Wait for utility voltage to return to normal. Generator is still running after switch transfers to utility power Engine cool down period. Engine will stop after 1 minute. Generator is still running after utility power is restored 1. Minimum engine run time has not elapsed. 2. Fuse(s) in transfer switch is defective. 1. Wait five minutes for transfer switch to retransfer to utility power. 2. Check fuse(s) and replace if necessary. 11 Briggs & Stratton Power Products Automatic Transfer Switch Installation and Owner’s Manual TRANSFER SWITCH SCHEMATIC 12 13 Briggs & Stratton Power Products Automatic Transfer Switch Installation and Owner’s Manual TRANSFER SWITCH WIRING DIAGRAM 14 Briggs & Stratton Power Products Automatic Transfer Switch Installation and Owner’s Manual TRANSFER SWITCH EXPLODED VIEW & PARTS LIST Item Part # Description 1 NSP LOADCENTER 2 192909GS BOARD, Control 3 192151GS HOLDER, Fuse 4 190984GS DECAL, Fuse 5 192597GS DECAL, Utility, 240 VAC 6 193626GS TAPTITE, #6 - 32 x 5/8" 7 B4854GS TERMINAL, SLS, 14-6 AWG 8 189916GS BAR, BUS, Copper 9 194205GS TAPTITE, #8 - 32 x 5/8" 10 185891GS RELAY, 50A 11 193239GS TAPTITE, #6-32 x 1/4" Item Part # Description 12 B4857GS FUSE, 2A 13 190983GS DECAL,Torque 14 190982GS DECAL, Lug 15 192701GS SPACER, 5/16" OD 16 190992GS DECAL,Warning 17 192707GS DECAL, 50A,ATS 18 192708GS DECAL, Identification 19 190850GS DECAL,ATS, BSPP 20 B5106GS DECAL, Utility Connection 21 B5107GS DECAL, Gen. Connection 23 198161GS COVER, Load Center w/ Decals MODEL 01917 NEMA 1 15 Briggs & Stratton Power Products Automatic Transfer Switch Installation and Owner’s Manual TRANSFER SWITCH EXPLODED VIEW & PARTS LIST Item Part # Description 1 NSP LOADCENTER 2 192909GS BOARD, Control 3 192151GS HOLDER, Fuse 4 190984GS DECAL, Fuse 5 192597GS DECAL, Utility, 240VAC 6 193626GS TAPTITE, #6 - 32 x 5/8" 7 B4854GS TERMINAL, SLS, 14-6 AWG 8 189916GS BAR, BUS, Copper 9 194205GS TAPTITE, #8 - 32 x 5/8" 10 185891GS RELAY, 50A 11 193239GS TAPTITE, #6-32 x 1/4" Item Part # Description 12 B4857GS FUSE, 2A 13 190983GS DECAL,Torque 14 190982GS DECAL, Lug 15 192701GS SPACER, 5/16" OD 16 190992GS DECAL,Warning 17 192713GS DECAL, 50A,ATS 18 192714GS DECAL, Identification 19 190850GS DECAL,ATS, BSPP 20 B5106GS DECAL, Utility Connection 21 B5107GS DECAL, Gen. Connection MODEL 01918 NEMA 3R Briggs & Stratton Power Products Automatic Transfer Switch Installation and Owner’s Manual NOTES 16 BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne...

Other models in this manual:
Portable Generators - 01917-0 (1.61 mb)
Portable Generators - 01917-0, 01918-0 (1.61 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category