User manual American Power Conversion, model 10000 VA

Manafacture: American Power Conversion
File size: 361.04 kb
File name: 1b9a7f4f-c99d-4a4b-88fe-26ce2a3d9a4a.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


The UPS filters small utility line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting from utility line power. The UPS provides continuous power from the internal battery until utility power returns to safe levels or the battery is fully discharged. INSTALLATION Read the Safety Instruction sheet before installing the UPS. Unpacking • Literature kit containing: Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. • Software CD The packaging is recyclable; save it for reuse or • Smart-UPS User Manuals CD dispose of it properly. • Serial cable Check the package contents. • Six output power cords • UPS • Two battery cable assemblies • Front bezel • Two ground wires • Product documentation, warranty information, and safety information • Network Management Card documentation Specifications TEMPERATURE OPERATING STORAGE 32° to 104° F (0° to 40° C) 5° to 113° F (-15 to 45 ° C) charge UPS battery every six months This unit is intended for indoor use only. Select a location sturdy enough to handle the weight. Do not operate the UPS where there is excessive dust or the temperature and humidity are outside the specified limits. Ensure the air vents on the front and rear of the UPS are not blocked. MAXIMUM ELEVATION OPERATING STORAGE 10,000 ft (3,000 m) 50,000 ft (15,000 m) HUMIDITY 0% to 95% relative humidity, non-condensing WEIGHT UPS UPS WITH PACKAGING 244 lbs (111 kg) 284 lbs (129 kg) 1 ATTACH THE BEZEL TO THE UPS HARDWIRING INSTRUCTIONS • Wiring must be performed by a qualified electrician. • Adhere to all national and local electrical codes. • Install a utility circuit breaker for input wiring, (see tables below). 220/230/240 V MODELS Input Connections Output Connection (optional) Single-Phase: Wire to L1, N, and . Three-Phase: Wire to L1, L2, L3, N, and . Wire to L1A, N1, and . System Wiring Number of Phases Voltage Current Full Load (Nominal) External Input Circuit Breaker (Typical) Wire Size (Typical) SURT8000 Input 1 220/230/240 V 40 A 50 A / 2-pole 10mm2 Input 3+ Neutral 380/400/415 V 15 A / phase when online 40 A on L1 in bypass 50 A / 4-pole 10mm2 Output 1 220/230/240 V 40 A (not required) 10mm2 SURT10000 Input 1 220/230/240 V 50 A 63 A / 2-pole 16mm2 Input 3+ Neutral 380/400/415 V 18 A / phase when online 50 A on L1 in bypass 63 A / 4-pole 16mm2 Output 1 220/230/240 V 50 A (not required) 16mm2 2 1. Switch the UPS input circuit breaker (see A in diagram) and utility circuit breakers OFF. 2. Remove the input access panel, (see B in diagram). 3. Remove circular knockout. 4. Run appropriate size wire through the access panel, and connect to the terminal block, (Green: Ground, Brown: Hot, Blue: Neutral). Connect the ground wire first. Use appropriate strain reliefs, (not included). 5. For three-phase input, set the input phase selector switch, (see C in diagram) to “3”. For single-phase input, leave the switch in the default position of “1”. 6. Replace the access panel. 3 CIRCUIT BREAKERS 8000/10000 VA Input Circuit Breaker The input circuit breaker must be switched on for the UPS to operate. The input circuit breaker protects the UPS from extreme overload conditions. 8000/10000 VA Output Circuit Breakers IEC 320-C13 10 A total current from four receptacles IEC 320-C19 16 A for each receptacle BASIC CONNECTORS Serial Com Power management software and interface kits can be used with the UPS. Use only interface kits supplied or approved by APC. Any other serial interface cable will be incompatible with the UPS connector. Ethernet Port Connect the UPS to the network using the Network Management Card. EPO Terminal Emergency Power Off terminal allows the user to connect the UPS to the central EPO system. TVSS Screw The UPS features a transient voltage surge-suppression (TVSS) screw for connecting the ground lead on surge suppression devices such as telephone and network line protectors. When connecting grounding cable, disconnect the unit from the utility power outlet. External Battery Pack Connectors External battery packs must be connected to these connectors located on the rear panel of the unit. 4 CONNECT THE EXTERNAL BATTERIES Battery Safety Read and adhere to the following warnings when installing or servicing the external batteries. Failure to observe these warnings may result in serious injury, death or damage to the equipment. WARNINGS • Do not attempt to install or service external batteries alone. A qualified electrician should perform the installation and servicing of external batteries. • Disconnect charging source(s) BEFORE connecting or disconnecting battery terminals. • External batteries may retain lethal voltages after power has been disconnected and all switches are off. • Use extreme caution when making terminal connections. Do not allow cables to touch anything except the intended terminal. PRACTICES Always wear: Goggles or face shields Acid-resistant, insulated gloves Protective aprons Protective overshoes or rubber boot...

Other models in this manual:
Power Supply - 220 VAC (361.04 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category