|
manual abstract
BASIC CONNECTORS Serial Port USB Port Power management software and interface kits can be used with the UPS. Use only interface kits supplied or approved by APC. Use an APC supplied cable to connect to the Serial Port. DO NOT use a stan- dard serial interface cable since it is incompatible with the UPS connector. Both Serial and USB Ports are provided. They cannot be used simultaneously. TVSS Screw The UPS features a transient voltage surge-suppression (TVSS) screw for connecting the ground lead on surge suppression devices such as telephone and network line protectors. When connecting grounding cable, disconnect the UPS from utility power. 4 2: OPERATION SMART-UPS FRONT PANEL Power On Power Off Online The online LED illuminates when the UPS is supplying utility power to the connected equipment. If the LED is not lit, the UPS is either not turned ON, or is supplying battery power. This LED illuminates to indicate the UPS is compensating for a high AVR Trim utility voltage. This LED illuminates to indicate the UPS is compensating for a low AVR Boost utility voltage. On Battery When the on battery power LED is lit the UPS is supplying battery power to the connected equipment. When on battery, the UPS sounds an alarm—four beeps every 30 seconds. Overload The LED illuminates and the UPS emits a sustained alarm tone when an overload condition occurs. 5 Replace Battery Failure of a battery self-test causes the UPS to emit short beeps for one minute and the replace battery LED illuminates. Refer to Troubleshooting in this manual. The replace battery LED flashes and short beep is emitted every two Battery seconds to indicate the battery is disconnected. Disconnected Automatic Self-Test The UPS performs a self-test automatically when turned on, and every two weeks thereafter (by default). During the self-test, the UPS briefly operates the connected equipment on battery. If the UPS fails the self-test, the replace battery LED lights and immediately returns to online operation. The connected equipment is not affected by a failed test. Recharge the battery for 24 hours and perform another self-test. If it fails, the battery must be replaced. Manual Self-Test Press and hold the button for a few seconds to initiate the self-test. On Battery Operation The Smart-UPS switches to battery operation automatically if the utility power fails. While running on battery, an alarm beeps four times every 30 seconds. Press the button (front panel) to silence the UPS alarm (for the current alarm only). If the utility power does not return, the UPS continues to supply power to the connected equipment until the battery is exhausted. If PowerChute® is not being used you must manually save your files and turn off the computer before the UPS fully discharges the battery. DETERMINING ON BATTERY RUN TIME UPS battery life differs based on usage and environment. It is recommended that the battery/batteries be changed once every three years. See the APC web site, for on battery run times. 6 3: USER CONFIGURABLE ITEMS NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE OR OPTIONAL SMART SLOT ACCESSORY CARDS. FUNCTION FACTORY DEFAULT USER SELECTABLE CHOICES DESCRIPTION Automatic Self-Test Every 14 days (336 hours) Every 7 days (168 hours), On Startup Only, No Self-Test This function sets the interval at which the UPS will execute a self-test. Refer to your software manual for details. UPS ID UPS_IDEN Up to eight characters to define the UPS Use this field to uniquely identify the UPS, (i.e. server name or location) for network management purposes. Date of Last Battery Replacement Manufacture Date Date of Battery Replacement mm/dd/yy Reset this date when you replace the battery module. Minimum Capacity Before Return from Shutdown 0 percent 15, 25, 35, 50, 60, 75, 90 percent The UPS will charge its batteries to the specified percentage before return from a shutdown. Voltage Sensitivity The UPS detects and reacts to line voltage distortions by transferring to battery operation to protect the connected equipment. Where power quality is poor, the UPS may frequently transfer to battery operation. If the connected equipment can operate normally under such conditions, reduce the sensitivity setting to conserve battery capacity and service life. Brightly lit: UPS is set to high sensitivity. Dimly lit: UPS is set to medium sensitivity. Off: UPS is set to low sensitivity. To change the UPS sensitivity, press the voltage sensitivity button (rear panel). Use a pointed object (such as a pen) to do so. You can change the sensitivity level through PowerChute software. Alarm Delay After Line Fail 5 second delay 30 second delay, At Low Battery Condition, No To avoid alarms for minor power glitches, set the alarm delay. Shutdown Delay 20 seconds 0, 60, 120, 240, 480, 720, 960 seconds Sets the interval between the time when the UPS receives a shutdown command and actual shutdown. 7 NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE OR ...
Other models in this manual:Power Supply - 230 VAC (418.44 kb)