Login:
Votes - 2, Average rating: 3.5 ( )

User manual American Power Conversion, model 3645A

Manafacture: American Power Conversion
File size: 275.5 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Set POWER Address: Login in the identity of the “Manager” and select the existing COM port. Then the “ADDRESS” page key will be available. Fig 4-5 POWER Address Set 3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL In Fig. 4-5, enter the default address (245) of the power supply and then click “READ”. If testing successfully, the “NEW ADDRESS” and “WRITE” functions will be available. If testing failure, then the new address of the power cannot be set and the prompting diagram as shown in Fig. 4-6 will be displayed. This time the communication cable must be checked. Fig 4-6 Communication Failure Explanation: For the first installation each POWER must be deployed with but one address in order to communicate correctly. Set the parameter and select “OK” and it will enter into the common communication. The default COM port is COM1 and the default POWER address is 0. 4.3 Start the Communication After the COM port and ADDRESS set, select the button and the system will start the communication. If the communication is normal, the prompt information as shown in Fig. 4-7 will be displayed. And if the commu nication is failure, the prompt information as shown in Fig. 4-8 will be displayed. Fig 4-7 Normal Communication Fig 4-8 Failure Communication 4.4 Stop the Communication Select the button and the system will stop the communication. 4.5 Select POWER In Fig. 4-9 , select the POWER name from the listing frame and it will be OK. Fig 4-9 Selecting the POWER 3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 4.6 Select PC to POWER Control Instructions 1.) Methods 1 As in Fig. 4-11, there are four control instructions in total. CLOSE POWER : Close the power output OPEN POWER : Open the power output PC CONTROL : ontrolled by PC POWER SELF : Control by power supply Fig 4-10-1 Select the Control Instruction Explanation: The system default control instruction is the PC CONTROL state. And when the system is closed or the POWER is switched, the system will be automatically set to POWER SELF state. 2.) Methods 2 POWER ON/OFF Set POWER Control Set Fig 4-10-2 Selecting Control Instruction 4.7 Set the Voltage Range There are two methods to set the voltage range: one is by using the rotary button and the other is by using the keypad (0.004~36.000). If you want to set accurately, please use the keypad. Fig 4-11 Using the Rotary knob Fig 4-12 Using the Keypad 1) Using the rotary knob: Move the mouse to the icon and then rotate the knob. 2) Using the keypad: Select the “V” button, enter the data and then select the “ENTER” button. 4.8 Set the Max Current There are two methods to set the voltage range: one is by using the rotary knob and the other is by using the keypad. If you want to set accurately, please use the keypad. In general, you can use the rotary knob. 3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL Fig 4-13 Fig 4-14 1) Using the rotary knob: Move the mouse to the icon and then rotate the knob. 2) Using the keypad: Select the “A” button, enter the data and then select the “ENTER” button. Explanation: User must have the authority above the “General” to do set it. 4.9 Query the Report Select the button and the diagram as shown in Fig. 4-15 will be displayed. Fig 4-15 Query the Report 1.) Set the Query Conditions: Set the parameters in the “Query” frame. 2.) Query: After setting the conditions, select “SEARCH” button and all the records compatible with the condi tions will be listed. 3.) Set the Report: Select “REPORT’ and it will be OK. 4.) Print the Report: Select “PRINT” and it will be OK. 5.) Query Totally: Select “TOTAL” and it will be OK. The data range must be selected and the other conditions cannot be selected. Its main function is to analyze several POWER so as to list the POWER that overflow the most data. The overflowing data includes the voltage overflowing, the current overflowing and the power overflowing. 6.) Delete the History Record: Select “DELETE” and the diagram as shown in Fig. 4-24 will be displayed. If you confirm to delete, select “YES” and it will be OK. Fig 4-16 Delete the History Data 3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL Explanation: The data range condition must be set. 7.) Close: Select “CLOSE” and return to the upper-interface. 4.10 Explanation of the Interface Indicating Components 1.) Instrument Part The Voltage Value (Accuracy rate: 2 digits) Voltage Set Value (Accuracy rate: 5 digits) Common Data: Green Overflowing Data: Red Fig 4-17 Instrument Indication Common Date and Overflowing Data are both in the normal communication state. 2.) Running Curve: Indicates the data acquired at the nearest 10 ports. The Voltage Running Diagram The Current Running Diagram 3.) Keypad Explanation Number Keys: 0-9 “.”: the point key “C”: the cleared key “ ”: the backspace key “V”: the voltage setting key (Unit: V) “A”: the current setting key (Unit: A) “mV”: the voltage setting...

Other models in this manual:
Power Supply - 3646A (275.5 kb)
Power Supply - 3644A (275.5 kb)
Power Supply - 3645A (275.5 kb)
Power Supply - 3646A (275.5 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category