Login:
Votes - 2, Average rating: 3.5 ( )

User manual Senco, model WARRANTY PC1108

Manafacture: Senco
File size: 908.54 kb
File name: PC1108_MAN.pdf
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


En este manual se incluyen avisos para el uso seguro de este compresor. PC 1108 Electric Air Compressor PC1108 Issued August 16, 2006Questions? Comments? call SENCO's toll-free Action-line: 1-800-543-4596 or e-mail: toolprof@senco.comSenco Products, Inc. 8485 Broadwell Rd. Cincinnati, OH 45244 © 2006 by Senco Products, Inc. 2 TABLE OF CONTENTSINTRODUCTION .........................................................................3SAFETY INSTRUCTIONS............................................................3INSPECTION ...............................................................................3SAFETY WARNINGS ..............................................................4-7ELECTRICAL..................................................................4EXPLOSION OR FIRE ...................................................5BURSTING......................................................................5BREATHING ...................................................................6BURNS ...........................................................................6FLYING OBJECTS .........................................................6MOVING PARTS ............................................................7NEGLIGENCE ................................................................7AIR COMPRESSOR DAMAGE ......................................7CALIFORNIA PROPOSITION 65 WARNING .................7COMPRESSOR FEATURES ......................................................8PREPARATION ........................................................................10INITIAL SET-UP ...........................................................10LOCATION ...................................................................10ELECTRICAL ...............................................................10OPERATION .............................................................................11PRE-START CHECKLIST .........................................................11START-UP .................................................................................11SHUTDOWN ..............................................................................11MAINTENANCE ........................................................................11TROUBLESHOOTING .........................................................12-14SPECIFICATIONS ....................................................................15WARRANTY .............................................................................16 3INTRODUCTIONCongratulations on the purchase of your new SENCO® Air Compressor! You can be assured your SENCO air Compressor was constructed with the highest level of precisionand accuracy. Each component has been rigorously tested by technicians to ensure the quality, endurance and performance of this air compressor. This operator's manual was compiled for your benefit. By reading and following the simple safety, installation and operation, and maintenance steps described in this manual, you will receive years of troublefree operationfrom you new SENCO Air Compressor. The contents of this manual are based on the latest productinformation available at the time of publication. The manufacturer reserves the right to make changes in price, color, materials equipment, specifications or models at any time without notice. SAFETY ALERT! A "DANGER, WARNING, or CAUTION" safety warning will be surrounded by a "SAFETY ALERT BOX". This box is used to designate and emphasize Safety Warnings that must be followed when operating this Air Compressor. Accompanying the safety warnings are "Signal Words" which designate the degree or level of hazard seriousness. The "Signal Words" used in this manual are as follows: DANGER:Indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. WARNING:Indicates an imminently hazardous situation which, if not avoided, COULD result in death or serious injury. CAUTION:Indicates an imminently hazardous situation which, if not avoided, MAY result in minor or moderate injury or damage to the air compressor. The symbols set to the left of this paragraph are "Safety Alert Symbols". These symbols are used to call attention to items or procedures that couldbe dangerous to you or other persons using this equipment. ALWAYS PROVIDE A COPY OF THIS MANUAL TO ANYONE USING THIS EQUIPMENT. READ ALL INSTRUCTIONS IN THIS MANUAL AND ANY INSTRUCTIONS SUPPLIED BY MANUFACTURERS OFSUPPORTING EQUIPMENT BEFORE OPERATING THIS AIR COMPRESSOR AND ESPECIALLY POINT OUTTHE "SAFETY WARNINGS TO PREVENT THE POSSIBILITY OF PERSONAL INJURY TO THE OPERATOR. INSPECTIONUnbox the air compressor and write in the serial number in the space provided below. Inspect for signs of obviousor concealed freight damage. Be sure that all damaged parts are replaced and any mechanical problems arecorrected prior to the operation of the air compressor. SERIAL NUMBER__________________________________________ If you have Questions or Comments call SENCO's toll fre...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category