Login:
Votes - 2, Average rating: 5 ( )

User manual Empire Comfort Systems, model DVX36DP31(N,P)-1

Manafacture: Empire Comfort Systems
File size: 4.77 mb
File name: 157ff0e0-36bb-4af8-a63c-1b9ea0a470e5.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Warning: ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN BE DANGEROUS. Improper installation or use of the fireplace can cause serious injury or death from fire, burns, explosions, or carbon monoxide poisoning. Page 6 25613-0-0309 25613-0-0309 Page 7 Figure 1 LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW ELECTRICAL ACCESS VENT COLLAR TOP VIEW GAS LINE ACCESS A C J G I GAS LINE ACCESS H D E B VENT COLLAR STANDOFFS NAILING FLANGES GLASS FRAME ASSEMBLY GAS LINE ACCESS RATING PLATE AND LABELS GAS CONTROLS AND SWITCHES Remote Control Options & Accessories Description FRBC Millivolt Battery Remote ON/OFF FRBTC Millivolt Battery Remote Thermostat TRW Millivolt WIRELESS Wall Thermostat TMV Millivolt REED SWITCH Wall Thermostat FWS-1 Millivolt Wall Switch FREC Electric Remote FBB4 Complete Blower Assembly (IP Only) NOTE: Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for optimum performance. SPECIFICATIONS FIREPLACE DIMENSIONS DVX36 NAT DVX36 LP DVX42 NAT DVX42 LP Input Btu/hr Maximum 35,000 30,000 37,500 35,000 Btu/hr Minimum 24,000 21,000 26,000 24,000 KWH (Maximum) 10.3 8.8 11.0 10.3 (Minimum) 7.2 6.2 7.6 7.2 Orifice #32 (P-211) 1.65 mm (P-250) #31 (P-209) #50 (P-245) Air Shutter Opening 1/4"(6.4 mm) FULL OPEN 1/4" (6.4 mm) FULL OPEN Height without standoff 34 3/4 (3.2 mm) 34 3/4" (3.2 mm) 34 3/4" (3.2 mm) 34 3/4" (3.2 mm) Width 39 3/8" (1,000 mm) 39 3/8" (1,000 mm) 43 3/8" (1,101 mm) 43 3/8" (1,101 mm) Depth 19 7/8" (505 mm) 19 7/8" (505 mm) 19 7/8" (505 mm) 19 7/8" (505 mm) Gas Inlet Shutoff Valve (Pipe) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT DVX Dimensions Dimension DVX36FP DVX42FP A 34 3/4" 882.7 mm 34 3/4" 882.7 mm B 39" 990.6 mm 43" 1092.2 mm C 19 7/8" 505 mm 19 7/8" 505 mm D 25" 635 mm 25" 635 mm E 36" 914.4 mm 40" 1016 mm G 26 1/2" 673.1 mm 26 1/2" 673.1 mm H 40 3/4" 1035.1 mm 40 3/4" 1035.1 mm I 13 1/4" 336.6 mm 13 1/4" 336.6 mm J 7 1/8" 181 mm 7 1/8" 181 mm Page 8 25613-0-0309 Mantel Chart (Figure 3) Figure 3 Clearances (Figure 4) Clearance from top front edge of fireplace to ceiling is 36" Clearance from side of fireplace to adjacent sidewall is 6". 36” (914mm) 6” (152mm) Figure 4 Figure 5 Note: Island (C) and Room Divider (F) installation is possible as long as the horizontal portion of the vent system (H) does not exceed 20 feet with a minimum vertical run of 8 feet. See details in Venting Section. When you install your Direct Vent Fireplace in (F) Room divider or (A) Flat on wall corner positions, a minimum of 6 inches clearance must be maintained from the perpendicular wall and the front edge of the appliance. Figure 2 Combustible Material No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. The flow of heat can ignite combustibles. (A) CORNER INSTALLATION (E) ANGLED CORNER INSTALLATION (C) ISLAND INSTALLATION (B) CABINET INSTALLATION (F) ROOM DIVIDER INSTALLATION (D) FLUSH WALL INSTALLATION Clearance to Combustibles Back 0" (0 mm) Side 0" (0 mm) Floor 0" (0 mm) Top Stand-off 0" (0 mm) Top Framing Edge 6" (152 mm) GLASS FRONT 6” SEE MANTLE CHART FOR MAXIMUM MANTLE DEPTH 2” x 4” HEADER STAND OFF 6” (152mm) HEIGHT ABOVE TOPOF FIREPLACE NAILING FLANGES TOP FRAMING LEDGE NON-COMBUSTIBLE FIRST 6” (SEE MAGNIFIED VIEW) FINISHED WALL (COMBUSTIBLE) SEE MANTLE CHART FOR MINIMUM HEIGHT OF MANTLE ABOVE UNIT CLEARANCES LOCATING FIREPLACE MANTEL 19” 18 3/4” 17” 16” 15” 14” 13” 12” 11” 10” 2 1/4” 1 1/2” 3/4” 8” 6” 4 1/2” 3 3/4” 3” 12” (305mm) 10” (254mm) TOP EDGEOF FIREPLACE COMBUSTIBLE TRIM AND MANTELS ALLOWED IN SHADED AREA GAS SUPPLY GAS SUPPLY The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter Tubing, Type L Outside Diameter Nat. L.P. Nat. L.P. 0-10ft 0-3m 1/2" 12.7 mm 3/8" 9.5 mm 1/2" 12.7 mm 3/8" 9.5 mm 11-40ft 4-12m 1/2" 12.7 mm 1/2" 12.7 mm 5/8" 15.9 mm 1/2" 12.7 mm 41-100ft 13-30m 1/2" 12.7 mm 1/2" 12.7 mm 3/4" 19 mm 1/2" 12.7 mm 101-150ft 31-46m 3/4" 19 mm 1/2" 12.7 mm 7/8" 22.2 mm 3/4" 1.9 mm Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code. The use of the following gas connectors is recommended: — ANSZ21.24ApplianceConnectorsofCorrugatedMetalTubing and Fittings. — ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than All-Metal Construction The above connectors may be used if acceptable by the authority havingjurisdiction.ThestateofMassachusettsrequiresthataflexible appliance connector cannot exceed three feet in length. Figure 6 Gas Supply Pressure (inches w.c.) Minimum Normal Maximum Natural Gas 4.5" 7.0" *14.0" LP (Propane) 10.8" 11.0" 14.0" Manifold Pressure (inches w.c.) Normal (...

Other models in this manual:
Gas Heaters - DVX36DP71(N,P)-1 (4.77 mb)
Gas Heaters - DVX36DP91(N,P)-1 (4.77 mb)
Gas Heaters - DVX42DP31(N,P)-1 (4.77 mb)
Gas Heaters - DVX42DP71(N,P)-1 (4.77 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category