manual abstract


5. When specified, in contaminated environments, the burner shall be capable of supplying outside air to each burner for the support of combustion. 6. All burners shall be pre-wired with a grounded electrical cord and plug. 7. At customer’s choice, burners may be controlled with either an optional line voltage thermostat or by optional low voltage thermostats with an appropriate low voltage transformer relay. 8. Gas supply to the burners shall conform to the following: 1/2” NPT gas connector size Natural Gas: 4.6” W.C. MIN, 14.0” W.C. MAX LP Gas: 11” W.C. MIN, 14.0: W.C. MAX B. Heat Exchanger 1. Radiant tubing shall be 4” diameter aluminized steel supplied in 10 ft. sections. Sections shall be joined with stainless steel wrap-around couplings. 2. Reflector to be of aluminum material and designed to direct all radiant output below horizontal centerline of radiant tube. 3. Heaters shall be vented according to manufacturer’s recommendations. Burner Ratings and Heat Exchanger Lengths: (Natural and LP) Model # Rate (BTU/Hr.) Heat Exchanger Length Turbulator ERXL-60 60,000 20 ft. 10 ft. ERXL-80S 80,000 20 ft. 10 ft. ERXL-80 80,000 30 ft. 10 ft. ERXL-100S 100,000 30 ft. 5 ft. ERXL-100 100,000 40 ft. None ERXL-125S 125,000 40 ft. None ERXL-125 125,000 50 ft. None ERXL-150 150,000 50 ft. None ERXL-150L 150,000 60 ft. None ERXL-175 175,000 50 ft. None ERXL-175L 175,000 60 ft. None Gas pressure at MANIFOLD: Natural Gas: 3.5” W.C. LP Gas: 10.5” W.C. 1/2” NPT Gas Connector Size Gas INLET pressure: Natural Gas: 4.6” W.C. Min 11.0” W.C. Max LP Gas: 11.0” W.C. Min 14.0” W.C. Max 1/2” NPT Gas Connector Size Electrical Rating: (All Models) 120V - 60Hz 1.0 AMP (Run) 5.0 AMP (Start) Dimensions: Flue Connection Size: 4” Outside Air Connection Size: 4” FIGURE 25: Ener-Radiant XL Dimensions & Suggested Mounting Heights Minimum Total Length (see chart below) Minimum Total Length (see chart below) Burner Side ViewXL13.75” 17.75” 9.25” Burner Rear View Turbulator (some Models) Reflector Heat Exchanger Tubing Model # Minimum Total Length Suggested Min. Space Mounting Height Spot ERXL-60 21” - 4” 10’ - 12’ 8’ - 10’ ERXL-80S 21” - 4” 12’ - 15’ 10’ - 12’ ERXL-80 31” - 4” 12’ - 15’ 10’ - 12’ ERXL-100S 31” - 4” 12’ - 15’ 12’ - 15’ ERXL-100 41” - 4” 15’ - 18’ 15’ ERXL-125S 41” - 4” 15’ - 20’ 15’ ERXL-125 51” - 4” 15’ - 18’ 15’ ERXL-150 51” - 4” 20’ - 23’ 20’ ERXL-150L 61” - 4” 20’ - 25’ 20’ ERXL-175 51” - 4” 20’ - 23’ 20’ ERXL-175L 61” - 4” 20’ - 25’ 20’ this page intentionally left blank. Operating Instructions and Owner’s Manual HEATSTAR WARNING: USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY. FOR INFORMATION REGARDING SERVICE OR PARTS: Contact your local heating service technician or dealer. FOR ADDITIONAL INFORMATION: Please call Toll-Free 800-251-0001—Our office hours are 8:30 AM — 5:00 PM, EST, Monday through Friday. Please have the model number, serial number and date of purchase ready. LIMITED WARRANTY The company warrants this product to be free from imperfections in material or workmanship, under normal and proper use in accordance with instructions of The Company, for a period of one year from the date of delivery to the buyer. The Company, at its option, will repair or replace products returned by the buyer to the factory, transportation prepaid within said one year period and found by the Company to have imperfections in material or workmanship. If a part is damaged or missing, call our Customer Service Department at 800-251-0001. Address any Warranty Claims to the Customer Service Department, ENERCO, 4560 W. 160TH ST., CLEVELAND, OHIO 44135. Include your name, address and telephone number and include details concerning the claim. Also, supply us with the purchase date and the name and address of the dealer from whom you purchased our product. The foregoing is the full extent of the responsibility of the Company. There are no other warranties, express or implied. Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability. In no event shall the Company be liable for delay caused by imperfections, for consequential damages, or for any charges of the expense of any nature incurred without its written consent. The cost of repair or replacement shall be the exclusive remedy for any breach of warranty. There is no warranty against infringement of the like and no implied warranty arising from course of dealing or usage of trade. This warranty will not apply to any product which has been repaired or altered outside of the factory in any respect which in our judgment affects its condition or o...

Other models in this manual:
Gas Heaters - ERXL-100 (1.11 mb)
Gas Heaters - ERXL-100S (1.11 mb)
Gas Heaters - ERXL-125 (1.11 mb)
Gas Heaters - ERXL-125S (1.11 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category