|
manual abstract
INSTALLING LOG SET: WARNING: If logs are not installed according to the directions in this manual, flame impingement and improper combustion could occur and result in excessive production of carbon monoxide (CO), a colorless, odorless, toxic gas. This appliance is equipped with a five-piece log set. Carefully install the logs into the firebox as shown on this page. All logs should fit down onto pins and mounts provided. This will ensure a proper flame and safe combustion. 1. Carefully place the largest log in the rear of the firebox as shown in the following illustration. 2. Install the front log and embers as shown in the following illustration. 3. Install the right top twig as shown in the following illustration. 4. Install the center top twig as shown in the following illustration. 5. Install the left top twig as shown in the following illustration. Glowing Embers Two packages of ember material have been included with the gas appliance. Unpackage and divide the fine ember material (mineral wool) into thumbnail sized pieces. Distribute the pieces over the top of the front burner ports, filling the area in front of the forward log and running the full length of the burner. PAGE 14 INSTALLATION INSTALLATION CHECK LIST (ALL MODELS) Read and understand these instructions before using appliance. Go through this installation checklist: ..• Ensure that the log set is properly installed. Use caution when handling the logs. See page 14. ..• Reinstall the door frame assembly. See Door Assembly on this page. WARNING: DO NOT OPERATE APPLIANCE WITH THE GLASS FRONT REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE GLASS SHOULD BE DONE BY A QUALIFIED TECHNICIAN. ..• Ensure venting termination cap is unobstructed. ..• Check to see that wiring is correct and is enclosed inside the stove pedestal base (See page 22). ..• (Model L20 DVF-2) Ensure that the relief door is properly closed. (see Combustion Chamber Relief Door on page 17). ..• Verify that the gas line has been purged of air. ..• Test all connections for leaks (factory and field) with a leak detector or soapy water solution. If you smell gas, do not attempt to light this appliance. Follow safety instructions on the front cover of this manual. ..• Burner Air Shutter opening to be: Natural Gas – 1/4 open, Propane 1/2 open. Some adjustment from standard may be necessary for the desired flame characteristics (see Burner Flame Appearance, page 21). To adjust air shutter: 1. Remove burner from firebox by removing the 2 nuts as shown in the following picture. Then lift burner up and out of firebox. Air Shutter Remove 2 nuts, then lift burner out of firebox. Burner Assembly 2. Adjust gap as shown in following picture. Loosen setscrew using Phillips Air Shutter screwdriver NG = 1/4 Open (1/8” gap)Burner Assembly LP = 1/2 Open (1/4” gap) 3. Reinstall burner. Do not overtighten nuts (finger tight only). ..• Light the appliance following the instructions on page 16 (Care and Operation). Relight the main burner in both the HI, and LO positions, and verify proper burner ignition and operation. ..• Perform Spillage Test Procedure (see Spillage Test Procedure, page 24). ..• With burner lit, check to make sure that the inlet gas and manifold pressures are correct (see Gas Pressure, page 4). Verify that the pilot and main burner ignition and operation are correct. NOTE: Upon the initial firing of your new gas stove, you may notice an odor. This may last up to two hours. It is recommended to open the windows to allow fresh air to circulate into the room. (see “Break In” Period, page 17). WARNING: IF THE PILOT DOES NOT LIGHT AFTER 1 MINUTE, WAIT AT LEAST 5 MINUTES FOR GAS TO CLEAR BEFORE ATTEMPTING AGAIN. PAGE 15 Thermocouple Igniter Electrode Pilot Hood Thermopile CARE AND OPERATION (ALL MODELS) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lit. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas co...
Other models in this manual:Gas Heaters - L20 BF-2 (1.84 mb)