|
manual abstract
A.3, 5/00 SECURITRON 32, 34, 62 AND 82 SERIES MAGNALOCK TABLE OF CONTENTS AND GUIDE TO THIS MANUAL There are numerous Magnalock versions and numerous different applications exist for them. Accordingly, this manual provides a broad range of information- only a portion of which is applicable to any individual use. This manual guide provides a brief summary of many of theSections which allows you to consult only the portions of the manual that apply to your application. SECTION 1. DESCRIPTION---------------------------------------------------------------------Page 1 SECTION 2. PHYSICAL INSTALLATION ---------------------------------------------------Page 1 This is the largest part of the manual with sections that explain the different types ofphysical installations which vary according to door or gate types as well as Magnalockversions. SECTION 2.1 SURVEY ---------------------------------------------------------------------------Page 1 This section concerns how to pre-plan the installation. SECTION 2.2 INSTALLATION TOOL KIT --------------------------------------------------Page 1 This section explains an available accessory. SECTION 2.3 GENERAL INSTALLATION ON OUTSWINGING DOOR ------------Page 1 SECTION 2.3.1 STRIKE PLATE MOUNTING----------------------------------------------Page 1 SECTION 2.3.2 MOUNTING THE MAGNET------------------------------------------------Page 3 The above three sections explain the most common Magnalock installation on a door thatswings away from the lock. They also include general mounting instructions and shouldtherefore be read for all installations. SECTION 2.4 GENERAL INSTALLATION ON INSWINGING DOOR ---------------Page 5 This section explains installation of "F" type Magnalocks on inswinging doors. SECTION 2.5 MOUNTING PROCEDURES FOR SPECIFIC DOOR TYPES -------Page 6 The following six sections provide specific advice depending on door type which includes recommended bracketry. SECTION 2.5.1 ALUMINUM FRAME GLASS DOOR MOUNTING-------------------Page 6 SECTION 2.5.2 THE UMB BRACKET FOR ALUMINUM AND CONCRETE ------Page 7 SECTION 2.5.3 SOLID GLASS DOOR MOUNTING--------------------------------------Page 8 SECTION 2.5.4 DOUBLE DOOR MOUNTING ---------------------------------------------Page 9 SECTION 2.5.5 CONCRETE HEADER OR WOOD FRAME MOUNTING ----------Page 9 SECTION 2.6 MOUNTING THE MAGNALOCK ON EXTERIOR GATES-----------Page 10 This section, which includes three drawings, covers outdoor use of the Magnalock on avariety of gate types. SECTION 2.7 USE OF DRESS COVERS----------------------------------------------------Page 12 This section introduces the Dress Cover which is used after physical mounting to improveinstallation appearance and tamper resistance. SECTION 2.8 TAMPER PROOFING THE MAGNALOCK ------------------------------Page 12 This section should be read for any installation in a high vandalism area. Copyright, 2000, all rights reserved Securitron Magnalock Corp., 550 Vista Blvd., Sparks NV 89434, USA Tel: (775) 355-5625 (800) MAGLOCK Fax: (775) 355-5636 Website: An ASSA ABLOY Group company Rev. A.3, 5/00 SECTION 3. ELECTRICAL INSTALLATION -----------------------------------------------Page 13 SECTION 3.1 GENERAL ELECTRICAL CHARACTERISTICS -----------------------Page 13 This section explains technically the Magnalock's electrical characteristics as a load and is for reference. SECTION 3.2 STANDARD LOCK -------------------------------------------------------------Page 13 This section explains powering and switching the Magnalock. SECTION 3.3 AVOIDING POOR RELEASE CHARACTERISTICS-------------------Page 13 This section warns against wiring mistakes specific only to the model 32 series. SECTION 3.4 WIRE GAUGE SIZING---------------------------------------------------------Page 14 This reference section explains how to select wire size for applications where the lock isdistant from the power supply. SECTION 3.5 SENSTAT MAGNALOCKS: “SC”------------------------------------------Page 14 Read this section if you have a Senstat Magnalock. SECTION 3.6 DOUBLE DOOR PROCEDURE FOR STATUS REPORTING-------Page 15 This section applies if you have Senstat locks on a double door and want them to report asa single lock. SECTION 3.7 DOUBLE DOOR CONTROL SWITCHING--------------------------------Page 15 This section applies whenever you have two locks controlled by a single switch. SECTION 3.8 EMERGENCY RELEASE -----------------------------------------------------Page 16 This section should be understood by all installers. APPENDIX A TROUBLESHOOTING----------------------------------------------------------Page i Refer to this section before calling the factory on any operating problem. APPENDIX B CALCULATING WIRE GAUGE SIZING-----------------------------------Page ii This detailed reference section explains how to select wire gauge in complicated multi-lockinstallations. APPENDIX C CONSIDERATIONS FOR MAXIMUM PHYSICAL SECURITY ------Page iii This reference section explains the technic...
Other models in this manual:Doors and Windows - 62 (417.89 kb)
Doors and Windows - 82 (417.89 kb)