Login:
Votes - 4, Average rating: 3.8 ( )

User manual Lifebreath, model CLEAN AIR FURNACE 60ELE

Manafacture: Lifebreath
File size: 425.41 kb
File name: cc8eb860-888f-4898-8c9b-89dd33c3b563.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


WiththeadditionofLifebreathT.F.P.AirCleaner(option- al)youwillhavetheultimateincomfortandhealthyindoorairquality.(Seebackcoverofthismanual) Onceitiscorrectlyinstalled,safetywillneverbeanissuewithyourLifebreathfurnace.Noflames,fumesorfluegasestobeconcernedabout. ThisOperatingandInstallationGuidewillhelpyoulearnaboutyourLifebreathCleanAirFurnacequicklyandeasi- ly.Thetableofcontentswillshowyouwheretofindinformationoneveryfeatureofthisunitalongwitheasytounderstandoperatinginstructions.If,however,youdoencounteraquestionthatisnotcoveredinthisGuideyoushouldcalltheLifebreathdealerwhoinstalledyourfur- nace.Chancesarethathewillbeabletogiveyouasatisfactoryanswerbutifheisunabletodosothenweinviteyoutocontactusdirectly. ThepurposeofthismanualistoactasaninstallationguideonlyfortheLifebreathCleanAirFurnace. AllnationalandlocalcoderequirementsmustbemetwheninstallingaLifebreathCleanAirFurnace.Besuretoconsulttheproperauthorities. Introduction......................................................................1TableofContents.............................................................1General............................................................................1Specifications................................................................2-4Installation...................................................................5-10WiringDiagram..............................................................11Start-upProcedure.........................................................12Operation.......................................................................13Troubleshooting.............................................................14MaintenanceandServiceRecord..................................15TableofContents CAF-03 Specifications18kw=(60,000BTUH) Voltage240VAC60HzHp1/3Amps(total)85StagesSingle(4sequence) Ventilation6" DuctsReturn14"x22" PlenumSupply17.25"x16" Airflow1350CFM@.25ESP1180CFM@.5ESPVentilation140CFMAirflowEffectiveness70% (HRV) Note:Allconnectionstobemadebyqualifiedcontractors. NetWeight150lbs.ShippingWeight165lbs. Specifications60ELE Core Ventilation system has patented aluminum heat recovery core for energy-efficient ventilation. Filters Washable air filters in exhaust and supply air streams of ventilation section, 1" Pleated in return plenum side. Case Prepainted galvanized steel for superior corrosion resistance. Dimensions & Clearances Side 16" Top 19" Duct (coil) Opening Front 29.5" 19" 6" 6" ® CLEAN AIR FURNA CE 14" 12" 4" *Ventilation Supply Air Inlet *Ventilation Exhaust Air Outlet 22" *Return Plenum Latches Blower Section Service Clearance 1' Service Clearance 3' 47.5" 17.25" 29.5" Options Warranty 99-186 Weatherhoods, Two -6" c/w Units carry a lifetime warranty on the heat recovery core and a 1/4" mesh screen five year replacement parts warranty on all other components. 99-130W Remote Wall Mount Dehumidistat Control 24 VAC only, 99-122 6” Balancing Damper 99-RSK6 6” Backdraft Damper 2 Specifications18kw=(60,000BTUH) Voltage240VAC60HzHp1/3Amps(total)85StagesSingle(4sequence) Ventilation6" DuctsReturn14"x22" PlenumSupply17.25"x16" Airflow1350CFM@.25ESP1180CFM@.5ESPVentilation140CFMAirflowEffectiveness70% (HRV) Note:Allconnectionstobemadebyqualifiedcontractors. NetWeight150lbs.ShippingWeight165lbs. Specifications60ELE-DF Core Ventilation system has patented aluminum heat recovery core for energy-efficient ventilation. Filters Washable air filters in exhaust and supply air streams of ventilation section, 1" Pleated in return plenum side. Case Prepainted galvanized steel for superior corrosion resistance. Dimensions & Clearances Front Side 29.5"19" 6" 6" ® CLEAN AIR FURNA CE 14" 12" 4"*Ventilation Supply Air Inlet *Ventilation Exhaust Air Outlet 22" *Return Plenum Latches Blower Section Service Clearance 1' Service Clearance 3' 47.5" 16" Top 19" Duct (coil) Opening 17.25" 29.5" Options Warranty 99-186 Weatherhoods, Two -6" c/w Units carry a lifetime warranty on the heat recovery core and a 1/4" mesh screen five year replacement parts warranty on all other components. 99-130W Remote Wall Mount Dehumidistat Control 24 VAC only, 99-122 6” Balancing Damper 99-RSK6 6” Backdraft Damper 3 Figure 1 Blower Performance Curve 4 Installation The purpose of this manual is to give the contractor guidelines for installing the Lifebreath Clean Air Furnace. All national and local codes relating to this type of equipment must be followed. Locating The Unit The Clean Air Furnace is designed to be installed vertically, in a conditioned space,where the surrounding temperature does not fall below 50°F (10°C). Attic installations are not recommended. Typically the unit is installed in a mechanical area of the basement, or other partitioned mechanical room, elsewhere in the home. A location close to an outside wall is recommended, as the ventilation supply and exhaust portion will need to be ducted to the outside air. Sufficient clearance around the unit is required for service of the filter, heat recovery core and components....


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category