Login:
Votes - 1, Average rating: 5 ( )

User manual Elektra Beckum, model SR 340

Manafacture: Elektra Beckum
File size: 896.9 kb
File name: f03c2a6f-e18d-4dac-980d-91bbc907926e.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


. . . . . . . . . . . . . . . . . . .L]iUyODJRVIHOH. VVpJ.QNWXGDWiEDQH]HQQHOLJD]ROMXNKRJ\H]D. termek kielegiti az alabbi szabvanyokban lefektetett N|YHWHOPpQ\HNHW PHJIHOHOD]DOiEELLUiQ\HOYHNH. tUiVDLQDN . SR 340 * prEN 792-6 ** 98/37/EG, 93/68/EWG Jurgen Kusserow Vorstand ELEKTRA BECKUM AG – Daimlerstra.e 1 – 49716 Meppen 1001007/ 01 ENGLISH 1. Tool Overview 1 2 5 3 4 1 3/4" square drive for sockets 2 Combination torque regulator forward/reverse selector 3 Air inlet 4 Exhaust 5 Trigger Not shown: socket set (26 mm, 27 mm, 29 mm, 30 mm, 32 mm, 35 mm, 36 mm, 38 mm) ENGLISH Table of Contents 1. Tool Overview.............................6 2. Please read first!.........................7 3. Safety...........................................7 3.1 Specified conditions of use...........7 3.2 Safety information.........................7 4. Operation.....................................7 5. Care and maintenance ...............7 6. Available accessories ................7 7. Repairs.........................................7 8. Environmetal protection ............7 9. Technical specifications............8 2. Please read first! • Read these instructions before use. Pay special attention to the safety information. • If you notice transport damage while unpacking, notify your supplier immediately. Do not operate the machine! • Dispose of the packing in an environmentally friendly manner. Take to a proper collecting point. • Keep these instructions for reference on any issues you may be uncertain about. • If you lend or sell this air tool be sure to have the instructions to go with it. 3. Safety 3.1 Specified conditions of use This air tool is used for running, driving and removing nuts and bolts. This air tool shall only be powered by an air compressor. The max. permissible working pressure stated in the Technical Specifications must not be exceeded. This air tool must not be operated with gases that are explosive, combustible or detrimental to health. Any other use is not as specified. Use not as specified, alteration of the machine or use of parts that are not approved by the equipment manufacturer, can cause unforeseeable damage! 3.2 Safety information . Danger! When using this air tool follow the safety instructions given below, to exclude the risk of personal injury or material damage. Keep all documents, supplied with the tool, for future reference. Observe the statuary accident insurance institution regulations and regulations for the prevention of accidents pertaining to the operation of air compressors and air tools, where applicable. Keep your work area tidy – a messy work area invites accidents. Be alert. Do not operate this tool while under the influence of drugs, alcohol or medication. Wear hearing protection. Always use a quick coupler to connect this air tool to a compressor. Make sure that the max. permissible working pressure stated in the Technical Specifications is not exceeded. Do not overload tool – use it only within the performance range it was designed for (see Technical Specifications). Do not touch any rotating parts. Disconnect tool from air supply before changing sockets or if left unattended. Do not attempt to repair the tool yourself! Only trained specialists are permitted to service or repair compressors, pressure vessels and air tools. 4. Operation . Caution: In order for this air tool to function properly, it must be supplied with sufficient qunatities of pneumatic oil. This can be achieved as follows: . By a service unit on the compressor. . By a lubricator, installed in the air line or directly on the air tool. . By adding approx. 3-5 drops of pneumatic oil by hand every 15 minuts of use (constant operation) to the air inlet. 1. Put socket on the drive. 2. Set direction of rotation by sliding the torque regulator into position: - F (= Forward) clockwise rotation/ driving - R (= Revers) counter-clockwise rotation/removing 3. Set torque between 1 to 6 at the torque regulator: - 1 = little torque - 6 = Maximum torque 4. Adjust working pressure at the compressor (see Technical Specifications for max. permissible working pressure). 5. Connect quick coupler to the compressor. 6. To start pull trigger. 5. Care and maintenance . Danger! Always disconnect tool from air supply before servicing. Repair and maintenance work other than described in this section must only be carried out by qualified specialists. • Check all screwed connections for tightness, tighten if necessary. • If the tool is not lubricated by a service unit or a line lubricator, add 3-5 drops pneumatic oil to the air inlet every 15 minutes of use (constant operation). • Do not store tool unprotected outdoors or in damp environment. 6. Available accessories • Pneumatic oil 0.5 litre Special oil for air tools, service units and line oilers. Stock-no. 090 100 8540 • Add-on lubricator R3/8" female Installs directly on air tool. Sight- glass always indicates oil level. Stock-no. 090 105 4592 7. Repairs . Danger! Repairs to air tool...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category