|
manual abstract
7. An extension cord should not be used unless absolutely necessary. Use of improper extension cord could result in a risk of fire, electric shock or electrocution. a. Two-wire cords can be used with 2-wire or 3-wire extension cords. Only round jacketed extension cords should be used, and we recommend that they be listed by Underwriters Laboratories (U.L.). If the extension is to be used outside, the cord must be suitable for outdoor use. Any cord marked for outdoor use can also be used for indoor work. The letters "W" or "WA" on the cord jacket indicate that the cord is suitable for outdoor use. b. An extension cord must have adequate wire size (AWG or American Wire Gauge) for safety, and to prevent loss of power and overheating. The smaller the gauge number of the wire, the greater the capacity of the cable; that is, 16 gauge has more capacity than 18 gauge. When using more than one extension to make up the total length, be sure each extension contains at least the minimum wire size. VEA EL ESPANOL EN LA CONTRAPORTADA. SAVE THIS MANUAL FOR FUTURE REFERENCE. INSTRUCTIVO DE OPERACION, CENTROS DE SERVICIO Y POLIZA DE GARANTIA. ADVERTENCIA: LEASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO. INSTRUCTION MANUAL CORDLLESS SCREWDRIIVER Cat No. PD600, PD600G Form No. 5145342-00 (NOV-04) Copyright © 2004 Black & Decker Printed in China 1 2 3 4 FEATURES - Quick Release Collar - Torque Control Collar - LED Light - Two Speed Switch - Accessory Holder - Pivot Button - Charging Port - Forward / Reverse Switch A BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 - 8 0 0 - 5 4 4 - 6 9 8 6 IF YOU SHOULD HAVE A QUESTION OR EXPERIENCE A PROBLEM WITH YOUR BLACK & DECKER PRODUCT, CALL 1-800-544-6986 BEFORE YOU CALL, HAVE THE FOLLOWING INFORMATION AVAILABLE, CATALOG No., TYPE No., AND DATE CODE (e.g. 0130M). IN MOST CASES, ABLACK & DECKER REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE. IF YOU HAVE ASUGGESTION OR COMMENT, GIVE US ACALL. YOUR FEEDBACK IS VITALTO BLACK & DECKER. C B D E F G H A B C D E F G H 5 Minimum Gage for Cord Sets Volts Total Length of Cord in Feet 120V 0-25 26-50 51-100 101-150 240V 0-50 51-100 101-200 201-300 Ampere Rating More Not more American Wire Gage Than Than 0 - 6 18 16 16 14 6 - 10 18 16 14 12 10 - 12 16 16 14 12 12 - 16 14 12 Not Recommended Catalog No. PD600, PD600G 8. Use only the supplied charger when charging your tool. The use of any other charger could damage the drill or create a hazardous condition. 9. Use only one charger when charging. 10. Do not attempt to open the charger. There are no customer serviceable parts inside. Return to any authorized Black & Decker service center. 11. DO NOT incinerate the tool or batteries even if they are severely damaged or completely worn out. The batteries can explode in a fire. 12. Do not incinerate the batteries. They can explode in a fire. A small leakage of liquid from the battery cells may occur under extreme usage, charging or temperature conditions. This does not indicate a failure. However, if the outer seal is broken and this leakage gets on your skin: a. Wash quickly with soap and water. b. Neutralize with a mild acid such as lemon juice or vinegar. c. If the battery liquid gets in your eyes, flush them with clean water for a minimum of 10 minutes and seek immediate medical attention. MEDICAL NOTE: The liquid is a 2535% solution of potassium hydroxide. Charging Procedure THE BATTERIES IN YOUR TOOL ARE NOT FULLY CHARGED AT THE FACTORY. BEFORE ATTEMPTING TO CHARGE THEM, THOROUGHLY READ ALL OF THE SAFETY INSTRUCTIONS. To charge your screwdriver, follow the steps below. 1. Plug the output cord of the charger into the socket in the bottom half of the screwdriver handle as shown in Figure 1. 2. Plug the charger into any standard 120 Volt 60 Hz electrical outlet 3. Let the tool charge initially for 9 hours. After the initial charge, under normal usage, your tool should be fully charged in 3 to 6 hours. WARNING: When disconnecting the tool from the charger, be sure to unplug the charger from the outlet first then disconnect the charger cord from the tool. Do not use the tool while it is connected to the charger. Important Charging Notes 1. After normal usage, your tool should be fully charged in 3 to 6 hours. If the batteries are run-down completely, it may take up to 6 hours to become fully charged. Your tool was sent from the factory in an uncharged condition. Before attempting to use it, it must be charged for at least 9 hours. 2. DO NOT charge the batteries in an air temperature below 40°F (4,5 °C) or above 105°F (+40,5 °C). This is important and will prevent serious damage to the batteries. Longest life and best performance can be obtained if batteries are charged when air temperature is about 75°F. 3. While charging, the charger may hum and become warm to touch. This is a normal condition and does not indicate a problem. 4. If the batteries do not charge properly—(1) Check current at receptacle by plugging in a lamp or other appli...
Other models in this manual:Power Screwdrivers and Drills - 5145342-00 (1.01 mb)