Login:
Votes - 3, Average rating: 3.3 ( )

User manual La Pavoni, model P300

Manafacture: La Pavoni
File size: 1.48 mb
File name: MAN_P300_ENG.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


00 ENG - Ottobre 2008 P300Cod. 2850012 - Rev. 00 ENG - Ottobre 2008 INDEX Technical characteristics ----------------------- 3 Installation ---------------------------------------- 4 Operating ----------------------------------------- 7 Programmation----------------------------------- 8 frequent menu --------------------------- 8 set drinks --------------------------------- 9 set prices---------------------------------- 10 counters & amounts--------------------- 11 events ------------------------------------ 12 main menu ------------------------------- 14 set time-------------------------------- 15 payment system---------------------- 16 set temperature----------------------- 17 options --------------------------------18 1st level -------------------------- 19 2nd level ------------------------- 20 set drinks ----------------------------- 23 quick functions -------------------------- 27 Troubleshooting guide -------------------------- 28 Hydraulic circuit --------------------------------- 29 Electrical diagram ------------------------------- 30 Pag. 2 ELECTRIC CIRCUIT LEGEND F anti-interference filter TR transformer 230Vac / 24 – 20 Vac 170VA I. P. door safety switch CX safety thermostat 145° C R. C. boiler heating element 230V 1200W R. G. espresso group heating element V ventilator CV flowmeter PS soluble pump PC espresso pump MG espresso group motor EV-A hot water Electro valve MS5 doser motor soluble 5 MS4 doser motor soluble 4 MS3 doser motor soluble 3 MS2 doser motor soluble 2 MS1 doser motor soluble 1 MZ “sugar in cup” doser motor EM-G to the obliterator coil (24Vdc) M-CB cup turret motor M-SB cup releaser motor EM-C coffee releaser coil EM- P spoon releaser coil E-S4/ 5 soluble 4 & 5 electro valve F-S4/ 5 soluble 4 & 5 whipper E-S1/ 2 soluble 1 & 2 electro valve F-S1/ 2 soluble 1& 2 whipper E-S3 soluble 3 electro valve F-S3 soluble 3 whipper EV-C espresso coffee electro valve M-M grinder motor S boiler temperature probe S-PB “cup” position sensor G. R. espresso group “normal” position sensor GET “token” microswitch S-B “cup” sensor MB cup-releaser motor S-PE “supply” position sensor S-PZ “sugar” position sensor M. B. cup-releaser switch D. C. coffee-doser switch V. A. lack water switch ( float) G. E. espresso group “supply” position micro switch Pag. 31 ELECTRIC DIAGRAM Pag. 30 TECHNICAL CHARACTERISTICS Dimensions: Height 162 cm Width 48.5 cm Depth 55 cm Weight: 90 Kg Voltage supply: 230 Vac. 50 Hz or 120 Vac. 60Hz on request Absorbed power: 1,6 KW Selections: n°14 for F300 model n°28 for F306 model Possibility to program up to 40 selections. Payment system: predisposed for · Obliterator / token system 24Vdc · Parallel selector 12Vac or 24Vac · Executive / MDB system Water connection: inside tank 15lit. From water system with male fitting of . " ( optional) Cups capacity: up to 300 Stirrers capacity: up to 300 Optional: · connection kit to the water net · double pump · beniamino filter ( anti-limestone filter) · whipper for powder container position 3 ( mod. Plus) Pag. 3 INSTALLATION Before proceeding to the operations of installation, maintenance and reparation of the machine, read the manual carefully, where there is contained the necessary information for the correct use of the machine. Install the machine in a dry and not dusty place. Put to level the machine through the regulation of the feet. ELECTRIC CONNECTION Before connecting the machine to the power, follow the following instructions: o check that the electric line has a suitable course for the absorbed power ( 1600W) o check that the voltage corresponds to the data indicated in the plate on the left side of the machine. o The power has to have the efficient earth connection. . o In case of substitution of the cable of feeding, use only original cables ( ask to the manufacturer the special cable with type M connection) The manufacturer will not take on any responsibility if these instructions are not respected. All the electric devices in the machine work with a 24Vdc produced by the transformer except the boiler heating element and the same transformer, that use a tension of 230Vac or 120Vac on request. The main light switch is a bipolar type and it supplies all the machine. There are two fuses, 2A and 12A, which respectively protect the transformer and the circuit in low voltage 24Vdc. In case you have to extract the breakdown fuses, unscrew the hood container. The 20Vac low-power circuit is interrupted by a safety button, situated on the chassis, that cuts the current to the electronic board when the door is open. Extracting the button, it is possible to reestablish the feeding with the door open ( by only technical staff) . Pag. 4 HYDRAULIC CIRCUIT Legend: EV Inlet electrovalve UC espresso group outlet D anti-limestone filtrer (optional) U1 mixer 1 outlet VA water reservoir (optional) U2 mixer 2 outlet CV flowmeter U3 mixer 3 outlet PS soluble pump PC espresso pump V one- way valve C boiler EV1 soluble 1 & 2 electrovalve EV2 soluble 3 a...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category