|
manual abstract
Flow Rate Capacity Space Requirements* QC7I Single - MH 1.67 gpm (6.3 Ipm) 9,000 gaI (34,050 L) 29" H x 51/5" W x 5" D QC7I Single - MH2 1.67 gpm (6.3 Ipm) 9,000 gaI (34,050 L) 29" H x 51/S" W x 5" D QC7I Twin - MH 3.3 gpm (12.6 Ipm) 18,000 gaI (68,100 L) 25" H x 11" W x 5" D QC7I Twin - MH2 3.3 gpm (12.6 Ipm) 18,000 gaI (68,100 L) 25" H x 11" W x 5" D QC7I Triple - MH 5.0 gpm (18.9 Ipm) 27,000 gaI (102,150 L) 25" H x 15" W x 5" D QC7I Triple - MH2 5.0 gpm (18.9 Ipm) 27,000 gaI (102,150 L) 25" H x 15" W x 5" D QC7I Quad - MH 6.6 gpm (25.3 Ipm) 36,000 gaI (136,200 L) 29" H x 24" W x 5" D QC7I Quad - MH2 6.6 gpm (25.3 Ipm) 36,000 gaI (136,200 L) 29" H x 24" W x 5" D Substance Influent Challenge Max. Permissable Product Reduction Minimum Average • Concentration Water Concentration Requirements Reduction Reduction • Standard 42- -Aesthetic Effects Chlorine o +i ra E o c\i > 50% 87.8% Particulate, • Class I at least 10,000 > 85% 99.2% particles 0.5 particles/mL to <1 Standard 53- -Health Effects Turbidity 11 ± 1 NTU 0.5 NTU 95.4% 97.2% Asbestos 107 to 108 fibers/L > 10 micrometers in length 99% 99.87% 99.87% Cyst Minimum 50,000/L 99.95% 99.99% 99.99% * Includes 21/2" clearance under unit for cartridge change SPECIAL NOTICES • Installation instructions, parts and service availability, and standard warranty are included with the product when shipped. • This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges. • Do not use with water that is microbiologically unsafe, or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. • The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water. Check for compliance with state and local laws and regulations. Tested under standard laboratory conditions as specified above. Actual performance may vary depending on influent water conditions. To determine NSF Model Name, combine HEAD NAME + CARTRIDGE NAME. Refer to to verify certification. * Tested using flow rate = 1.67 gpm; pressure = 60 psig; pH = 7.5 ± 1; temp. = 20° ± 3°C t NTU = Nephelometric Turbidity Units GENERAL INSTALLATION/OPERATION/MAINTENANCE REQUIREMENTS • Install vertically with cartridge hanging down • Use minimum length of tubing possible • Flush to drain for 5 minutes at full flow • Replace cartridges when capacity is reached or when flow becomes too slow, but at least annually. System Tested and Certified by NSF International against NSF/ANSI Standards 42 and 53 for the reduction of: Standard No. 42 — Aesthetic Effects Chemical Reduction Taste and Odor Chlorine Mechanical Filtration Particulate Class I: 99.2% reduction of particles one-half micron and larger in size Standard No. 53 — Health Effects Mecha...
Other models in this manual:Water Dispensers - EV9613-26 (452.02 kb)
Water Dispensers - EV9613-06 (452.02 kb)
Water Dispensers - EV9613-21 (452.02 kb)