Do not obstruct the front ventilation grille. If Wine Vault is installed under countertop or in cabinet, it is recommended that a ventilation hole be cut to allow for proper ventillation of the unit. A flush mount grill may be used in this case to prevent large objects from falling down vent opening. See diagram on page 6. The Wine Vault should be installed in a place where the ambient temperature is between 72-78°F. If the ambient temperature is above or below recommended temperatures, the performance of the unit may be affected. For example, placing your unit in extreme cold or hot conditions may cause interior temperatures to fluctuate. The range of 40-65°F may not be reached. Remove protective shipping materials from inside the Wine Vault. Remove the protective paper from the charcoal filter that you will find in the accessories pack. From inside the cabinet, position the filter in the round box located in the top back of the cabinet. Arrange the shelves to suit your convenience (see section 6.) Wait 48 hours before switching the cabinet on so as to allow the fluids to settle. If you need to move the Wine Vault, do not tip over 45 degrees, and only tip towards the back of the unit. Make sure you can access the plug of the unit for servicing or moving when needed. 5 6 Installation 22.5" 23.4" 23.5" 4.25" 32"- 32.5" minimum 22.6" 22.5" Installing in Cabinet or with Decorative Door 1. Level the Unit inside the cabinet 2. Open the door or the unit at a 90° angle 3. Fix the facing of the kitchen cabinet on the door of unit (8 screws included) 4. Be sure the gasket is sealed properly 33 lbs. 23.4" with 23.6" 27.5" 31.3" 33 lbs. 23.6" 31.3" 23.4" with 27.5" Air entry grid 79"2 minimum Temperature Settings Temperature Settings Set temperature for Lower Layer by adjusting +/- buttons Left Digital Display Set temperature for Upper Layer by adjusting +/- buttons Right Digital Display Compressor Indication LED ON/OFF Key Right Digital Display: Indicate the current temperature or preset temperature of upper layer. When +/- Key is pressed, display on the digital tube flashes, indicating the preset temperature. If no temperature setting operation occurs within five seconds, the system will automatically return to the display of ambient temperature in the storage cabinet, with the accuracy of 1°F. Malfunction Code Explanation: E2 Faults of upper layer’s cabinet temperature sensor. The sensor is short circuit or open circuit (10 seconds later the system will close and this code will display. The buzzer will tweet every 2 seconds). E9 is Superheating protection. After compressor operating 4 hours under any condition, When the upper layer sensor detects the cabinet temperature no less than 77°F, The buzzer will alarm and tweet every 2 seconds. When the detected cabinet temperature is >86°F, “E9” malfunction code will display. The Electrical Heating will close and compressor will go on working. (The buzzer will tweet every 2 seconds). When Upper layer sensor detects the cabinet Temperature reaches 70°F, the system will restart automatically and the temperature will display normally. Preset Temperature Adjusting Key for Upper Layer: Press this key to adjust the preset temperature of upper layer. Every time it is pressed, the preset temperature of upper layer is increased or decreased by 1°F. Temperature setting range is 54°F - 72°F. Left Digital Display: Indicate the current temperature or preset temperature of lower layer. When +/- Key is pressed, display on the digital tube flashes, indicating the preset temperature. If no temperature setting operation occurs within five seconds, the system will automatically return to the display of ambient temperature in the storage cabinet, with the accuracy of 1°F. Malfunction Code Explanation: E3 Faults of lower layer’s cabinet temperature sensor. The sensor is short circuit or open circuit (10 seconds later the system will close and this code will display. The buzzer will tweet every 2 seconds). E8 is Supercooling protection. When the lower layer sensor detects the cabinet temperature reaches 37°F , the compressor will stop, but electrical heating keeps going on. “E8” malfunction code ...

Other models in this manual:
Water Dispensers - WV-100 (674.92 kb)
Water Dispensers - WV 50 (674.92 kb)
Water Dispensers - WV 150 (674.92 kb)
Water Dispensers - WV 50 (674.92 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category