Login:
Votes - , Average rating: ( )

User manual Culligan, model 7850S

Manafacture: Culligan
File size: 2.6 mb
File name:

Language of manual:enesfr

The document is loading, please wait
The document is loading, please wait

manual abstract


10.Pull pullout spout in and out to check for free movement of hose. If needed, adjust the placement of weight to aid the clearance of the hose. 11.Faucet flushing is required before installation is complete. (See below) LINE FLUSHING INSTRUCTIONS IMPORTANT: Pipe chips, sand, stones and other solids found in new and renovated plumbing can damage the sealing surfaces of the filter cartridge and cause a leak. To avoid damage, DO NOT TURN ON SUPPLY VALVES until instructed below. 1. Pull hose out of spout receptor, tie a cloth around the hose to keep it from slipping back into the spout receptor. 2. Unscrew the hose from the bottom of the quarter turn connector (18) and remove screen washer. Turn on supply valves. Direct hose into sink, then turn the faucet on in the full cold position (handle pointing to the right) to turn on the cold water supply for 3-5 minutes. 3. Leaving the handle in the open position, turn to the full hot position (handle pointing to the left) and turn on the hot water supply for 3-5 minutes. 4. Place handle in the closed position. Remove the quarter turn connector (18) from pullout spout and reassemble with screen washer to hose. Do not reassemble pullout spout to quarter turn connector since MicroTech filter installation is required. Check under the sink for system leaks. HELPLINE: 1-800-BUY-MOEN INS115D INS115D 8HELPLINE: 1-800-BUY-MOEN MICROTECH™ FILTER INSTALLATION NOTE: Faucet will not operate in any mode without filter. Filter should be left in protective bag until ready for installation. The MicroTech™ filter is a high performance carbon block filter developed specially for the PureTouch Filtering Faucet System. Once the filter is installed in the pullout spout, it should not be removed until it is to be replaced. The electronic module keeps track of the amount of filter life remaining and will signal you when the filter change is necessary. If a partially used filter is removed and reinstalled, the electronic indicator will automatically reset and will not accurately reflect filter life remaining. Use only MicroTech filter cartridges with the PureTouch Filtering Faucet System 1. Remove the filter cover by lifting it up and away from the pullout spout body. 2. Insert the new filter by aligning the outlet tubes on the filter with the inlet ports of the spout body and gently pressing in and down. Upon successful installation of the filter cartridge, the filter life indicator will beep three times and reset automatically. (Do not remove the filter until it is to be replaced.) 3. Reinstall the filter cover by positioning the alignment tab with the corresponding notch in the main pullout spout body and gently pushing in and down. 4. Attach the pullout spout to the hose by aligning the dots on the quarter turn connector (18) and the spout. Push the quarter turn connector onto the spout assembly and turn it clockwise, locking it in place. 5. Allow cold water to run through the new filter for 5 minutes to flush out any loose carbon particles. (See page 9 for filtered water mode.) Once these small black particles are washed out the filter is ready for use. The PureTouch System installation is now complete. Please read carefully the operation instructions to ensure optimal performance. CARE AND MAINTENANCE All that is needed to clean your faucet is a soft damp cloth. Moen does not recommend the use of scour pads, cleansers or chemicals. The abrasive nature of these substances could damage the faucet’s finish. A non abrasive car wax will help to protect the finish. DO NOT PLACE WAND APPLIANCE IN DISHWASHER. ALIGN DOTS (2) (3) (4) CARE AND MAINTENANCE All that is needed to clean your faucet is a soft damp cloth. Moen does not recommend the use of scour pads, cleansers or chemicals. The abrasive nature of these substances could damage the faucet’s finish. A non abrasive car wax will help to protect the finish. DO NOT PLACE WAND APPLIANCE IN DISHWASHER. ALIGN DOTS (2) (3) (4) OPERATING INSTRUCTIONS Controlling The Water The PureTouch System has three options for water delivery; unfiltered stream, unfiltered spray and filtered water. The spray and stream actuating buttons are on the sides of the pullout spout, the filtered water button is located on the front of the spout. Stream/Spray flow rate = 2.2gpm maximum at 60psi / 2.5gpm maximum at 80psi. STREAM MODE: Unfiltered water in regular stream flow. When the water is turned on at the faucet, the spout will always begin operating in the regular stream mode. SPRAY MODE: Unfiltered water in a wide pattern. If a wide spray mode is desired, push the spray button while the water is on. To return to stream mode, push the stream button. FILTERED WATER MODE: Filtered water dispensed through the separate filtered water outlet. Pressing the front filtered water button will divert water through the filter and dispense filtered water from a separate outlet. The only way to exit the filter mode is to shut the faucet off. CAUTION: Only filter cold water. Do ...

Other models in this manual:
Water Dispensers - 7850 (2.6 mb)
Water Dispensers - 7850W (2.6 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category