User manual APC, model INROW RP ACRP500

Manafacture: APC
File size: 944.86 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Hinged rear doors . Casters (all swiveling) . Side panel lock . Door handle and lock . Removable side panel . Display interface . Adjustable leveling foot . Hinged front door InRow RP Technical Data Manual 10 InRow RP Technical Data Manual Chilled Water Interior Components (front of unit) . Electric heater (for reheat) . Electrical panel . Fan . Supply temperature sensors . Fan guard . Main feed breakers . Humidifier . Ladder diagrams . Condensate drain pan . User interface connectors . Condensate pump . Supply humidity sensor na2090a InRow RP Technical Data Manual 11 Chilled Water Interior Components (back of unit) . Chilled water coil . Rear doors . Chilled water control actuator . Air filters . Chilled water three-way valve body . Return humidity sensor . Flow meter . Return temperature sensor . Pipe chase na2105a 12 InRow RP Technical Data Manual Air-cooled Interior Components (front of unit) . Electric heater (for reheat) . Main circuit breaker . Condensate drain pan . Fan . Thermal expansion valve . Fan guard . Receiver . Electrical panel . Compressor . Ladder diagrams . Variable Frequency Drive (for compressor) . Communication and external device connectors . Supply air temperature sensor . Humidity sensor na2070a InRow RP Technical Data Manual 13 Air-cooled Interior Components (back of unit) . Evaporator coil . Shutoff valves (top piping only) . Condensate drain pan . Air filters . Sight glass . Pipe chase . Filter dryer . Humidity sensor . Condensate pump . Return air temperature sensor . Humidifier na2074a Chilled Water and Air-cooled User Interface Connections na2009a . Rack inlet temperature sensors 1, 2, 3 . A-Link IN A-Link OUT . Network port . Console port . Alarm output, NC (Normally Closed) . Alarm output, COM (Common) . Alarm output, NO (Normally Open) . Supply GND (Ground) . Supply 12 Vdc (current limit: 20 mA) . Supply 24 Vdc (current limit: 20 mA) . Customer input + (12–30 Vac/Vdc, 24 Vdc @ 11 mA) . Supply COM . BMS D1 (RXTX+) . BMS D0 (RXTX–) . BMS GND . Supply air temperature sensor (front) . Supply air humidity sensor (front) . Display interface . Note: For a top installation, control wiring is routed through the wire channel located at the top left hand corner just above the user interface connectors. For a bottom installation, the control wiring is routed to the access hole in the bottom of the equipment through wire clamps from the interface connectors. Then, the wiring is routed down along the electrical panel and secured with wire clamps. InRow RP Technical Data Manual InRow RP Technical Data Manual 15 Chilled Water Electrical Panel Note: ACRP501 shown. . Transformers . User interface connectors . Main controller board . Relay board . Ground lug . Main circuit breaker — power feed A . Main circuit breaker — power feed B . Automatic transfer switch (ATS) contactors . ATS timers . ATS transformer (ACRP501 only) . ATS timer circuit breakers . Fan circuit breakers . Controller circuit breaker . Humidifier circuit breaker . Heater circuit breaker . Heater contactors . Humidifier contactor na2008a 16 InRow RP Technical Data Manual Air-cooled Electrical Panel Note: ACRP 101 shown. . Transformers . User interface connectors . Main controller board . Relay board . Ground lug . Main circuit breaker . Compressor fuse block (ACRP100, ACRP101) . Compressor circuit breaker (ACRP102) . Fan circuit breakers . Controller circuit breaker . Humidifier circuit breaker . Heater circuit breaker . Heater contactors . Humidifier contactor na2032a Performance Specifications Chilled Water Performance Specifications 5.5°C (42°F) EWT Temperature dry bulb(DB), wet bulb (WB) °C (°F) CW Delta T °C (°F) Total Net CapacitykW (BTU/hr) Sensible Net CapacitykW (BTU/hr) Sensible Heat Ratio SHR CW Flow Rate l/s (GPM) Total CW Pressure DropkPa (ft H2O)* 26.7°C DB, 17.1°C WB (80°F DB, 62.8°F WB) 6.6 (12) 44.3 (151,000) 40.7 (139,000) 0.92 1.6 (25.9) 66 (21.95) 7.7 (14) 40.8 (139,000) 37.9 (129,000) 0.93 1.3 (20.6) 42 (14.1) 8.8 (16) 37.8 (129,000) 35.2 (120,000) 0.93 1.1 (16.8) 29 (9.5) 10 (18) 34.6 (118,000) 32.5 (111,000) 0.94 0.9 (13.8) 19 (6.5) 11.1 (20) 31.8 (109,000) 29.9 (102,000) 0.94 0.7 (11.5) 14 (4.6) 29.4°C DB, 18.1°C WB (85°F DB, 64.5°F WB) 6.6 (12) 50.8 (174,000) 47.8 (163,000) 0.94 1.9 (29.5) 84 (28.4) 7.7 (14) 47.7 (163,000) 44.8 (153,000) 0.94 1.5 (23.9) 56 (18.7) 8.8 (16) 44.1 (151,000) 41.9 (143,000) 0.95 1.2 (19.4) 38 (12.5) 10 (18) 41.2 (141,000) 39.1 (134,000) 0.95 1.0 (16.2) 26 (8.8) 11.1 (20) 37.8 (129,000) 36.3 (124,000) 0.96 0.8 (13.5) 19 (6.2) 32.2°C DB, 18.9°C WB (90°F DB, 66.1°F WB) 7.7 (14) 54.5 (186,000) 52.3 (179,000) 0.96 1.7 (27.1) 71 (23.8) 8.8 (16) 51.4 (175,000) 49.3 (168,000) 0.96 1.4 (22.4) 49 (16.6) 10 (18) 47.8 (163,000) 46.3 (158,000) 0.97 1.2 (18.6) 35 (11.6) 11.1 (20) 44.8 (153,000) 43.4 (148,000) 0.97 1.0 (15.7) 25 (8.32) 35.0°C DB, 19.8°C WB (95°F DB, 67.7°F WB) 7.7 (14) 62.0 (212,000) 60.2 (205,000) 0.97 1.9 (30.6) 90 (30.3) 8.8 (16) 58.8 (201,000) 57.0 (195,000) 0.97 1.6...

Other models in this manual:
Water Dispensers - INROW RP ACRP100 (944.86 kb)
Water Dispensers - INROW RP ACRP502 (944.86 kb)
Water Dispensers - INROW RP ACRP501 (944.86 kb)
Water Dispensers - INROW RP ACRP102 (944.86 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category