|
Other manuals for this model:
manual abstract
on the control button once.* the current message go back to previous Press . on the control button repeatedly. (During the stop mode, messages keep the button pressed to go back the messages continuously.) skip to the next message Press > on the control button once.* skip to the succeeding Press > on the control button repeatedly. (During the stop mode, messages keep the button pressed to skip the messages continuously.) * These operations are for when “Easy Search” is set to “OFF” (page 73). Display when playing back the messages A File information Press v or V on the control button to check the file information during playback. A message recorded using the IC recorder is displayed as follows. : Folder name: FOLDER01-FOLDER10 : Title: Date_file number (e.g. 090101_001 or FM_090101_001) : Artist name: My Recording : File name: Date_file number (e.g. 090101_001 or FM_090101_001) You can change the folder name, title, artist name, and/or file name using a computer. Basic Operations 23 23 GB B B You can select the display mode in the menu (page 74). Elapsed time: Elapsed playback time of one message Remaining time: The remaining time of the message Recording date: Date recorded Recording time: Time recorded C Remaining recording time Displays the remaining recording time in hours, minutes, and seconds. If there is more than 10 hours time remaining, the time is displayed in hours. If there is more than 10 minutes and less than 10 hours time remaining, the time is displayed in hours and minutes. If there is less than 10 minutes time remaining, the time is displayed in minutes and seconds. 24 24 GB Erasing Erasing • Once a recording has been erased, you cannot retrieve it. • Before erasing a message, exit HOLD mode and turn on the power. Selecting a message and erasing it 1 Select the message you want to erase when the IC recorder is in the stop or playback mode. 2 Press ERASE. “Erase?” appears with the message title. ERASE 3 Press v or V on the control button to select “Execute.” v V Basic Operations 25 25 GB 4 4 N/ENT selected message will be erased. When a message is erased, the remaining messages will advance and be renumbered so that there will be no space between messages. To cancel erasing 1 Select “Cancel” in step 3 of “Selecting a message and erasing it,” and then press N/ENT. N/ENT Erasing another message Proceed with the same steps again from the beginning. Erasing a part of one message Divide the message into two messages first (page 55), and then proceed with the same steps from the beginning. 26 26 GB Other Recording Operations Other Recording Operations Selecting the recording mode x STOP N/ENT MENU v, V You can select the recording mode in the menu when the IC recorder is in the stop mode or the FM radio mode. 1 Press MENU to enter the menu mode. The menu mode window will be displayed. 2 Press v or V on the control button to select “REC Mode,” and then press N/ ENT. 3 Press v or V on the control button to select “ST,” “STSP,” “STLP,” “SP,” or “LP,” and then press N/ENT. 4 Press x STOP to exit the menu mode. Other Recording Operations 27 27 GB ST ST STSP Standard play stereo recording mode (44.1 kHz/128 kbps) You can record with stereo sound. STLP Long play stereo recording mode (22.05 kHz/48 kbps) You can record for a longer time with stereo sound. SP Standard play monaural recording mode (44.1 kHz/32 kbps) You can record with standard quality sound. LP Long play monaural recording mode (11.025 kHz/8 kbps) You can record for a longer time with monaural sound. To record with better sound quality, select the ST or STSP mode. The recording mode is set to “ST” when you purchase the IC recorder. PNote You cannot set the recording mode while recording. Setting the microphone sensitivity x STOP N/ENT MENU v, V You can set the microphone sensitivity in the menu when the IC recorder is stopped or is recording. 1 Press MENU to enter the menu mode. The menu mode window will be displayed. 28 28 GB 2 2 3 Press v or V on the control button to select “S-High ,” “High ,” “Low ,” and then press N/ENT. 4 Press x STOP to exit the menu mode. To record a sound far away from the IC recorder or a low sound, such as a recording made in a spacious room. S-High To record the sound of a normal conversation or meeting, such as a recording made in a conference room or during interviews. High To record dictation with a microphone in front of your mouth, a sound near the IC recorder, or a loud sound. Low The microphone sensitivity is set to “High ” when you purchase the IC recorder. Other Recording Operations 29 29 GB Cutting out low frequency – the LCF function Cutting out low frequency – the LCF function x STOP N/ENT MENU v, V When you set the LCF (Low Cut Filter) function to “ON” in the stop or recording mode, you cut out a low frequency to reduce the roaring noise from wind, etc.; therefore you can record a message more clearly. 1 Press MENU to enter the menu mode. The menu mode window will be displayed. 2 Press v or V on t...
Other models in this manual:Dictaphones - ICD-UX200 (5.74 mb)
Dictaphones - ICD-UX300 (5.74 mb)
Dictaphones - ICD-UX300F (5.74 mb)