Login:
Votes - 5, Average rating: 4.2 ( )

User manual Sony, model ICD-UX80

Manafacture: Sony
File size: 1.67 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


If unwanted noise is heard, wipe the headphones plug clean. GB *3 When you slide the HOLD switch in the direction of the arrow in the stop mode, the IC recorder turns off within a few seconds. To turn the IC recorder on, slide the HOLD switch in the opposite direction from that of the arrow. During recording and playback slide the switch in the direction of the arrow to lock all the functions of all the buttons so that you can prevent inadvertent operations. Display window . Operation mode indicator Displays the following, depending on the current operation mode : stop : playback : recording : recording standby/recording pause : recording with the VOR function : recording pause with the VOR function (flashing) If you press . (record/pause) to pause recording when “VOR” is set to “ON” in the menu, only “ ” flashes. GB : review/fast backward, cue/fast forward : going backward/forward continuously . Folder name/ Message title name/ Artist name indication Press the control key toward .or . to display a folder name, message title name, and artist name in sequence. . Elasped time/Remaining time/ Recording date and time indication . Selected message number/Total number of messages in the folder . Microphone sensitivity indicator Displays the microphone sensitivity. (high) : To record at a meeting or in a quiet/spacious place. (low) : To record for dictation or in a noisy place. . Alarm indicator Appears when the alarm is set for a message. . Recording mode indicator Displays the recording mode set using the menu when the IC recorder is in the stop mode, and displays the current recording mode when the IC recorder is in the playback or recording mode. : Standard play stereo recording mode with high quality sound : Standard play stereo recording mode : Long play stereo recording mode : Standard play monaural recording mode : Long play monaural recording mode . Remaining battery/Charging indicator When a dry battery is used, the indicator shows the remaining battery power. While charging the rechargeable battery an animation appears. GB . Remaining recording time indication Displays the remaining recording time in hours, minutes, and seconds. If there is more than 10 hours time remaining, the time is displayed in hours. If there is more than 10 minutes and less than 10 hours time remaining, the time is displayed in hours and minutes. If there is less than 10 minutes time remaining, the time is displayed in minutes and seconds. 10 10 GB Getting Started Step 1: Preparing a Power Source Inserting the battery 1 Slide and lift the battery compartment lid. 2 Insert one LR03 (size AAA) alkaline battery with correct polarity, and close the lid. When using Sony NH-AAA rechargeable battery (not supplied) 1 Follow the steps 1 and 2 on the left, and then insert a NHAAA rechargeable battery (not supplied). 2 Charge the battery by connecting the USB connector of the IC Computer IC recorder To USB connector Getting Started recorder to your computer. While the battery is charging, “CONNECTING” and the remaining battery/charging indicator are displayed in an animation. 11 11 GB When the remaining battery/charging indicator indicates “ ,” charging is completed. (Charging time: approx. 8 hours*) When you use the IC recorder for the first time, or after you have not used the IC recorder for a certain time, it is recommended that you charge the battery repeatedly until “ ” is displayed. If the remaining battery/charging indicator is not displayed, charging has not been done properly. Proceed from step 1 again. * This is an approximation for the time it takes to charge from no remaining battery power to full battery power at room temperature. It varies depending on the remaining power and the condition of the battery. It also takes more time if the temperature of the battery is low, or if the battery is charged while you are transferring data to the IC recorder. If the IC recorder cannot be connected to your computer directly, use the supplied USB connection support cable. .Tip You can charge the rechargeable battery by connecting the IC recorder to an AC outlet using a USB AC adaptor (not supplied) (page 60). .Notes . While “ ” or “ ” is flashing instead of the remaining battery/charging indicator, you cannot charge the battery. Charge the battery in an environment with a temperature of 5 °C - 35 °C. . If “USB CHARGE” in the “DETAIL MENU” menu is set to “OFF,” you cannot charge the battery using your computer. Set “USB CHARGE” to “ON” (page 43). . Do not use manganese battery for this IC recorder. . During playback using the built-in speaker, you cannot charge the battery. . When you use the IC recorder with a rechargeable battery, the remaining battery/ charging indicator may not light fully. Clock setting display appears and the year section flashes when you insert battery for the first time, or when you insert battery after the IC recorder has been without battery for a certain period of time. Please refer to step 3 in “Step 2: Settin...

Other models in this manual:
Dictaphones - ICD-UX60 (1.67 mb)
Dictaphones - ICD-UX70 (1.67 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category