manual abstract


Use by more than one person may present a health risk, performance questions and voids the warranty. When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following: READ ALL INSTRUCTIONS DANGER: To reduce the risk of electrocution: 1. Always unplug electrical products immediately after using. 2. Do not use while bathing. 3. Do not place or store product where it can fall or he pulled into a tuh or sink. 4. Do not place in or drop into water or other liquid. 5. Do not reach for a product if it has fallen into water. Unplug immediately. WARNING: To reduce the risk of bums, electrocution, fire or injury to persons: 1. A product should never be left unattended when plugged into an electric outlet. 2. Close supervision is necessary when this product is used by, on or near children or invalids. 3. Use the product only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. 4. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. 5. Keep the cord away from heated surfaces. 6. Do not use outdoors, or operate where aerosol (spray) products are being used or where oxygen is being administered. 7. Plug the transformer into Double Deluxe first and then into wall socket. 8. Only use the transformer that comes with the Double Deluxe Breastpump. 9. This product is a personal care item and shouldn’t be shared between mothers. 10. Make sure the voltage of the transformer is compatible with the power source. 11. Never use while sleeping or drowsy. 12. Do not use the Vehicle Lighter Adapter with a Double Deluxe Breastpump. SAVE THESE INSTRUCTIONS Double Deluxe' Breastpump English Table of Contents Uses.....................1 Health & Safety Information .... 2 Cleaning, Hygiene, Storing Breastmilk Assembly Instructions .........4 Battery & Electric Operation To Begin Pumping Pumping Tips...............6 Troubleshooting.............7 Accessories................7 Warranty .................8 Ordering Parts..............9 Breastpump Parts List .........9 Parts....................21 Español - Instrucciones .......10 IMPORTANT This product has been designed for single user use and should not be shared between mothers. Disassemble all parts prior to cleaning and sterilization. Especially be sure to remove the valve from the breastshield frame and separate the white membrane from the valve prior to cleaning or sterilization. See parts 5 and 6 on breastpump parts lists (Page 9). Uses H Collect breastmilk during short-term occasional absences from the baby. H Maintain a milk supply if breastfeeding is temporarily interrupted. H Relieve engorgement or sore nipples. Pumping with simultaneous massage is helpful to relieve engorgement. 1 Double Deluxe' Breastpump NOTE: For long-term or frequent pumping; when the baby is not available to feed at the breast at least part of the time every day (a premature baby, for example), use of a full-size electric pump (Lactina® or Classic™ Breastpump) is suggested. These pumps can be rented inexpensively for home use. For the names of rental stations or breastfeeding specialists in your area, call 1-800-TELL YOU (1-800-835-5968). IMPORTANT: When using the pump, do not overfill or tilt the containers. Health & Safety Information Please read this section before using any Medela Breastpump. Cleaning & Sanitizing Prior to first use and before use each day, follow these cleaning instructions at home unless you are otherwise instructed by your physician or another medical professional from your hospital. Boil Disassemble, wash, and rinse all parts (except motor unit) that come in contact with the breast or the milk. Boil cylinder/piston assembly, including rubber parts, weekly or when milk spots appear. • Place parts in a 4-5 quart pan. • Fill to within 1 inch of rim with cold water. The use of distilled water will help to minimize deposits onto components. • Cover and boil for 20 minutes. • Remove from stove. Drain water off. Allow parts to cool in open pan. • Remove all parts and allow to air-dry. Use of microwave sterilization is not recommended and may damage some components. After each use: Wash Disassemble and wash all parts that come in contact with the breast and milk in soapy water or wash in top-rack of dishwasher. The motor unit may be wiped with a damp cloth. Rinse in clear water. Air-dry Air-dry on clean towel and cover parts when not in use. The tubing should be 2 Double Deluxe' Breastpump hung to air-dry. For faster drying, attach tubing to the pump and run for 1-2 minutes or until dry, or pour a small amount of isopropyl alcohol through the tubing to dry. Carefully swinging the tubing in a circular motion, will also help to speed drying. Tubing Care Inspect tubing after each pumping session for...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category