Login:
Votes - , Average rating: ( )

User manual Andersen Windows & Doors, model AN74I

Manafacture: Andersen Windows & Doors
File size: 1.53 mb
File name:

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


The door is assembled from a molded polystyrene outer door and inner stainless steel liner. The door is provided with an exterior grain finish stainless steel cover panel, door support arm and latching lock with removable key. Protective rubber feet are attached to the lower cabinet panel. A.2. Pumps: The lower cabinet is ventilated by means of two linear oscillating pumps located in the enclosed top cabinet. The pumps remove the air from inside of the lower cabinet and sterilization liner bag and exhaust the air to the outside. The 3/4” (1.9 cm) inside diameter braided PVC tubing may be up to 200 feet (60.96 meters) in length. During sterilization and ventilation cycles, the pumps maintain a negative pressure (vacuum) in the lower cabinet with respect to the room where the sterilizer is located. If an abator is installed it uses a third linear pump that is enclosed in the abator cabinet. A.2.a. Ventilation Pump: The cabinet ventilation pump will run continuously from the time the operator pushes the START button at the beginning of the cycle until the 12 or 24 hour sterilizing cycle is complete. After that, during the 2 hour purge cycle, it will alternate with the purge pump, running for two minutes and then shutting down for two minutes until the operator: 1.Opens the door to remove the sterilized items; and 2.Presses the EXIT button. The cabinet ventilation pump is designed to exhaust the lower cabinet at a minimum rate of 38 liters per minute. These specifications are for a cabinet equipped with a maximum of 200 feet (60.96 m) of 3/4” (1.9 cm) inside diameter braided PVC tubing with one 90. bulkhead fitting at the back of the cabinet and one 90. bulkhead fitting at the interior wall above the sterilizer. Additional Aeration: If the operator wishes to use the sterilization cabinet to further aerate the sterilized items after the normal 14/26 hour sterilization and ventilation cycles are completed, the operator may simply leave the sterilizer running when the UNLOAD STERILIZER screen appears. A count-up timer will appear on the screen showing the additional aeration time after the end of the normal 14/26 hour sterilization and aeration cycle. When the operator wishes to stop the additional aeration, they simply need to follow the steps outlined in A.2.a. above. A.2.b. Purge Pump: The second exhaust pump, referred to as the purge pump, is connected to the purge tube assembly and sterilization liner bag by a tube connected to the front right corner of the lower cabinet. Purging is the intermittent flushing of the sterilization liner bag with fresh air and takes place at the beginning and end of the cycle. © Andersen Products Ltd OWNER’S MANUAL OWNER’S MANUAL APPENDIX B Installation Requirements © Andersen Products Ltd OWNER’S MANUAL OWNER’S MANUAL APPENDIX B AN74i Anprolene Sterilizer Dimensions and Clearances and Installation Requirements Total weight is approximately 50.5 pounds (22.9kg). It is advisable to have two persons assist in the installation or moving of the machine. Refer to installation instructions in Appendix C for detailed instructions. 14” (35cm) 22.9” (58.1cm) 21” (53.3cm) 12” (30.5cm) 20.5” (52cm) 14” (35.5cm) 1.5” (3.81cm) APPENDIX BAN74ix Anprolene Sterilizer Dimensions and Clearances and Installation Requirements 14” (35.5cm) 20.5” (52cm) 14” (35.5cm) 1.5” (3.81cm) 12” (30.5cm) 30.5” (77.5cm) 32.4” (82.3cm) Total weight is approximately 60.5 pounds (27.5kg). It is advisable to have two persons assist in the installation or moving of the machine. Refer to installation instructions in Appendix C for detailed instructions. © Andersen Products Ltd OWNER’S MANUAL OWNER’S MANUAL APPENDIX B Dimensions and Clearances and Installation Requirements B.1 The AN74 i/ix Sterilizer consists of three major components: (1) a lower cabinet which is used to contain the items being sterilized; (2) an upper cabinet containing the controller, user interface display and pneumatic equipment to ventilate the lower cabinet and sterilization bag; and (3) a 3/4” (1.9 cm) I.D. exhaust tube and fittings which vent the Ethylene Oxide laden air from the lower cabinet and sterilization liner bag to the outside. B.2 The total weight of the AN74 i/ix is approximately 50.5 pounds (22.9 kg) / 60.5 pounds (27.5 kg). It is advisable to have two persons assist in the installation or moving of the machine. Refer to installation instructions in Appendix C and following for detailed instructions. Place the sterilizer cabinet on a sturdy counter space or workbench at a height convenient for loading. B.3 CAUTION!: The Anprolene sterilizer cabinet location must be adjacent to an UNSWITCHED, GROUNDED power outlet, preferably one that is dedicated to its exclusive use. The standard Anprolene sterilizer is fitted with a 7 foot long (220 cm) power cord. B.4. Whenever possible, the Anprolene sterilizer should be located against an outside wall, and exhaust directly to the outside by means of 3/4” (1.9 cm) I.D. tubing to minimize the im...

Other models in this manual:
Baby Accessories - AN74IX (1.53 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category