Manafacture: Sony
File size: 197.8 kb
File name:
|
manual abstract
To cancel Time Edit Press PLAY MODE. When using the remote, press CONTINUE. Tips • You can set the tape length freely using l AMS L. Example: When the tape length of one side is 30 minutes and 15 seconds 1 To set the minutes, turn l AMS L until “30” appears in the display, then pushl AMS L. 2 To set the seconds, turn l AMS L until “15” appears in the display, then pushl AMS L. • To check and change your programme, see page 12. Adjusting the Recording Level (Peak Search) The player locates the highest level among the tracks to be recorded to let you adjust the recording level before you start recording. 1 Before you start playing, press PEAK SEARCH. “PEAK” flashes in the display and the player starts scanning the disc searching for the highest peak level. After scanning all the tracks, the player repeats the portion with the highest peak level. 2 Adjust the recording level on the deck. 3 Press x on the player to stop Peak Search. “PEAK” disappears from the display. Note The portion with the highest level may differ every time you try the adjustment on the same disc. The difference is, however, so slight that you won’t find any problem in adjusting the recording level precisely. Additional Information Additional Information Using the CONTROL A1II control system (CDPXE570 only) This player is compatible with the CONTROL A1II Control System. The CONTROL A1II control system was designed to simplify the operation of audio systems composed of separate Sony components. CONTROL A1II connections provide a path for the transmission of control signals that enable automatic operation and control features usually associated with integrated systems. Currently, CONTROL A1II connections between a Sony MD deck, CD player, amplifier (receiver), and cassette deck provide automatic function selection and synchronized recording. In the future the CONTROL A1II connection will work as a multifunction bus allowing you to control various functions for each component. Note The CONTROL A1II control system is designed to maintain upward compatibility as the control system is upgraded to handle new functions. In this case, however, older components will not be compatible with the new functions. CONTROL A1II and CONTROL A1 compatibility The CONTROL A1 control system has been updated to the CONTROL A1II which is the standard system in the Sony 300 disc CD changer and other recent Sony components. Components with CONTROL A1 jacks are compatible with components with CONTROL A1II, and can be connected to each other. Basically, the majority of the functions available with the CONTROL A1 control system will be available with the CONTROL A1II control system. However, when making connections between components with CONTROL A1 jacks and components with CONTROL A1II jacks, the number of functions that can be controlled may be limited depending on the component. For detailed information, refer to the operating instructions supplied with the component(s). Connecting the CONTROL A1II control system Connect monaural (2P) mini-plug cables in series to the CONTROL A1II jacks on the back of each component. You can connect up to ten CONTROL A1II compatible components in any order. However, you can connect only one of each type of component (i.e., 1 CD player, 1 MD deck, 1 tape deck and 1 receiver). (You may be able to connect more than one CD player or MD deck, depending on the model. Refer to the operating instructions supplied with the respective component for details.) Example Amplifier CD player MD deck Other component continued Recording From CDs(CDP-XE570 only) Additional Information Using the CONTROL A1II control system (CDP-XE570 only) (continued) In the CONTROL A1II control system, the control signals flow both ways, so there is no distinction of IN and OUT jacks. If a component has more than one CONTROL A1II jack, you can use either one, or connect different components to each jack. About the connecting cable When a CONTROL A1II compatible component is not supplied with a connecting cable, use a commercially available monaural (2P) mini-plug cable less than 2 meters (6.6 feet) long, with no resistance (such as the Sony RK-G69HG). Basic functions of the CONTROL A1II control system Automatic function selection When you connect CONTROL A1II compatible Sony components using CONTROL A1II cables (not supplied), the function selector on the amplifier (or receiver) automatically switches to the correct input when you press the play button on one of the connected components. (For example, when you press H (play button) on the CD while the MD deck is playing, the function selector on the amplifier switches from MD to CD.) Notes • This function works only when the components are connected to the amplifier (or receiver) inputs according to the names on the function buttons. Certain receivers allow you to switch the names of the function buttons. In this case, refer to the operating instructions supplied with the receiver. • When recording, do not play any c...
Other models in this manual:CD Players - CDP-XE270 (197.8 kb)
CD Players - CDP-XE370 (197.8 kb)
- ()
- ()