|
manual abstract
cold cuts which you are not intending to consume within the next few days. Description A Motor part B On/off switch (MR 5500: turbo/MR 4050: speed 2) C Release buttons (MR 5500 only) D Vacuum pump E Pump cover F FreshWare G Lid H Valve lid I Pump coupling J Day/month indicator K Vacuum indicator L Valve seal M Lid seal N Tray O Rectangular container How to use your vacuum system 1. Attach the pump cover (E) to the vacuum pump (D) and insert the motor part (A) into the vacuum pump until it locks. 2. Place the lid (G) on the FreshWare container and close the valve lid (H). 3. Place the vacuum pump into the pump coupling (I). The vacuum indicator (K) is fully expanded, signalling that there is no vacuum inside the container. 4. Plug in the appliance, press firmly on the lid and operate the on/off switch (B) in order to create vacuum conditions. The longer you press the switch, the more the vacuum indicator retracts. A full vacuum has been created when the vacuum indicator is completely below the valve lid surface. Keep the pump working for a few more seconds for optimum vacuum conditions. 5. In order to release the vacuum, simply open the valve lid. Upon opening, the freshness sound will be heard and the vacuum indicator will move up. 6. To remove the vacuum pump from the motor part, press the release buttons (C) and pull off (MR 5500) or turn (MR 4050). Please note: • In the unlikely case that a vacuum is created, but then gets lost within a short period of time, ensure that all parts are clean. • Do not fill a container more than 10 mm below the brim. For storage in the freezer, please assure that the big containers are not filled more than 20 mm below the brim. • Before using the containers in an oven or microwave, make sure you remove both the lid (G) as well as the tray (N). • The tray (N) is designed to protect food from exuded liquids during storage. Liquids will flow under the tray avoiding contact with the food. • Raw meat will become darker under vacuum conditions. After a few minutes in contact with air again, it will partly recover its natural colour. As this is a normal process, there will be no impact on the quality of the food. • During storage, vacuum conditions are acceptable as long as the vacuum indicator stays in line with the valve lid surface. What to do if vacuum cannot be generated • Ensure all parts are clean. The sealing elements (valve and lid seal) and the lid especially have to be completely free from dust, fluff or food particles. Rinse them under water and let them air-dry. • If all parts are clean and the vacuum still cannot be generated, press firmly on the lid (G) to make sure that it is completely closed. • Thanks to a protection system in the pump cover, the vacuum pump will only work if it is inserted in the pump coupling. Benefits of the Braun fresh system (validated by Fraunhofer Institute, Germany) Refers to storage in a refrigerator: between -1 and +7 °C I. Fresh food is kept fresh for longer. Storage Standard (days) Vacuum (days) Fresh vegetables, sliced (e.g. peppers, courgettes) 6 10-12 Fresh fruit (e.g. fruit salad) 3 10 Dips (e.g. guacamole) 0 2 Crisps (e.g. tortilla/potato chips) 3 30 II. A significant benefit of the fresh system is that the taste and freshness of food or prepared meals can be sealed inside the container, maintaining current texture and especially taste up to the storage times listed below. Oven prepared meals 15 days* (e.g. lasagne) White/brown bread 5 days Dark bread 7 days Cheese 10-14 days Cold cuts 7 days III. After 6 days under vacuum conditions, vitamin C content is maintained 100%. Without vacuum storage, only up to 65% is maintained. it cool down below 40 °C and vacuumise it without adding or removing anything. Cleaning Before you use the Braun fresh system for the first time, rinse all parts thoroughly. Clean the motor part (A) and the vacuum pump (D) with a damp cloth only. Do not hold the motor part nor the vacuum pump under running water, nor immerse them in water. All other parts can be cleaned in the dishwasher. Remove the valve lid (H), lid seal (M) and valve seal (L) to clean them separately in the dishwasher or rinse them under water and let them air-dry. To remove the valve lid (H) completely, lift and pull out. Be careful not to use excessive detergent or descaler in your dishwasher. About FreshWare The stackable FreshWare containers are made from hardened borosilicate glass and are microwave, oven, freezer and dishwasher safe. Therefore, they can be used for food preservation as well as reheating and serving. Your starter set includes two of the four FreshWare sizes available: • 3.1 l rectangular container: Ideal for the preparation of food for your family and friends. Can be used as a serving dish and to store larger quantities of food. • 0.9 l rectangular container: Ideal for food preparation in smaller quantities and for the preservation of leftovers as well as cold cuts and hard cheese. We also offer the following round Fr...
Other models in this manual:Blenders - MR4050 CA (2.69 mb)