Login:
Votes - , Average rating: ( )

User manual Honeywell, model FocusBT AP-100-BT

Manafacture: Honeywell
File size: 1.07 mb
File name:

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


Default settings will not be listed (see example in Figure 13). Figure 13. Scanner Settings All the settings shown in Figure 13 are for illustrative purposes only and will differ depending upon the configuration. † Minimum system requirements: A personal computer with Microsoft® Windows® 95 or greater with an available RS232 serial or USB port and MetroSet2 (minimum software version 3.2.016). ‡ Scanner model is application dependent. UPLOADING AND DOWNLOADING SETTINGS Downloading Settings via MetroSet2 The download† feature in MetroSet2 allows the user to download custom configuration settings selected in MetroSet2 to the access point and the linked ‡ scanner . To download settings via MetroSet2: 1. Verify the access point device is connected to the host system and a communication link has been established with a scanner. 2. Start the MetroSet2† software. 3. Click on the plus sign (+) next to POS Scanners to expand the supported scanner list. 4. Choose Focus BT with Access Point ‡ from the list. 5. Select an interface (i.e. RS232, Keyboard Wedge, USB) then click OK. 6. Select and modify the configuration options in the Scanner Functions Menu. 7. Choose Save As from the File menu to save the configuration. Figure 14. Global Defaults Page 8. Click on the Down button. 9. A communications window will open displaying the progress of the download. The unit will beep and a message will appear in the window when the download is complete. † Minimum system requirements: A personal computer with Microsoft® Windows® 95 or greater with an available RS232 serial or USB port and MetroSet2 (minimum software version 3.2.016). ‡ Scanner model is application dependent. 16 UPGRADING THE FIRMWARE Upgrading the Firmware in the Access Point Device The access point device is part of Metrologic's product series with flash upgradeable firmware. The upgrade process requires, a new firmware file supplied to the customer by a customer service representative.. and Metrologic's MetroSet2 software..• . A personal computer running Windows 95 or greater with an available RS232 serial or USB port is required to complete the upgrade. Do not use the standard cable supplied with Keyboard Wedge or RS485 Access Point interface kits for firmware upgrades. If using USB or RS232 for the upgrade process, the standard USB or RS232 cable provided with the scanner can be used. To upgrade the firmware in the access point device: 1. Plug the unit into a serial communication port on the host system. 2. Start the MetroSet2 software. 3. Click on the plus sign (+) next to POS Scanners to expand the supported scanner list. 4. Choose the Focus BT with Access Point from the list. 5. Click on the Configure Focus BT with Access Point Scanner button. 6. Select the interface from the Prompt Window. 7. Choose AP NEC or AP Silabs from the options list located on the left side of the screen to upgrade firmware in Access Point device. 8. Click on the Select File button in the window. 9. Locate and open the flash upgrade file supplied by Metrologic. 10. Select the COM port that the scanner is connected to on the host system. 11. Verify the settings listed in the Flash Utility window. 12. Click on the Flash Scanner button to begin the flash upgrade. 13. A message will appear on the screen when the upgrade is complete. • Metrologic's customer service department can be reached at 1-800-ID-METRO or 1-800-436-3876. ..• MetroSet2 is available for download, at no additional cost, from UPGRADING THE FIRMWARE Upgrading FocusBT Firmware via the Access Point Device With MetroSet2, scanner firmware upgrades can be accomplished through the communication link between the access point device and scanner. This feature is not supported in scanners using the CodeXML protocol. The scanner must be in Metro protocol mode. Do not use the standard cable supplied with Keyboard Wedge, USB or RS485 Access Point interface kits for firmware upgrades. If using RS232 for the upgrade process, the standard RS232 cable provided with the scanner can be used. To upgrade the firmware in FocusBT via the access point device: 1. Plug the unit into a serial communication port on the host system. 2. Start the MetroSet2 software. 3. Click on the plus sign (+) next to POS Scanners to expand the supported scanner list. 4. Choose the Focus BT with Access Point from the list. 5. Click on the Configure Focus BT with Access Point Scanner button. 6. Select the interface from the Prompt Window. 7. Choose FocusBT from the options list located on the left side of the screen to upgrade FocusBT firmware. 8. Click on the Select File button in the window. 9. Locate and open the flash upgrade file supplied by Metrologic. 10. Select the COM port that the scanner is connected to on the host system. 11. Verify the settings listed in the Flash Utility window. 12. Click on the Flash Scanner button to begin the flash upgrade. 13. A message will appear on the screen whe...

Other models in this manual:
Wireless Accessories - FocusBT AP-010-BT (1.07 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category