Login:
Sorted: Name ↑   Downloads   Rate   Size ↑  
downloaded: 29   File size: 548 kb   Manafacture: Jacuzzi  
Category: Swimming Pools
@name

Refer to product dataplate(s) for additional operating instruction and specifications. Inspection Examine the equipment when received. Notify your dealer or carrier of any damage or missing parts. Verify that equipment is of size and model specified. Important Safety Instructions When installing and using this electrical equipment, basic safety precations should always be followed, including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. WARNING – To reduce risk of injury, do not permit

downloaded: 17   File size: 5 mb   Manafacture: Jacuzzi  
Category: Swimming Pools

WIRE SIZE MUST BE BLUJ6 BRNJ5 BRNBRNBLUBLKBLUBLUBRNBLUBRN BLU BLUBRN BRN 21 FLOW SWITCHHI - LIMIT / FREEZE SENSOR TEMPERATURE SENSOR J1 J2J3 F120A, 250VSC-20 PUMP 1PUMP 2 TRANSFORMER240 VACF1 JP142 31 6 5 8 7 HIHILO C Control Panel CIRC.PUMP J20 K1K2K3K4K5K6 K7 K8 J21J11J12J13J14J15J16J17J18J19 J7 J8 J9 J10 Logic Jumper Settings (Factory Defaults Shown)JP1 1-2 ON = 20A Logic JP1 1-2 OFF = 30A Logic JP1 3-4 ON = 2 Pump OperationJP1 3-4 OFF = 1 Pump OperationJP1 5-6 ON = 40A Logic (Remove JP1 1-2

downloaded: 11   File size: 5 mb   Manafacture: Jacuzzi  
Category: Swimming Pools

an infection, bacteria or virus) and/or respiratory ailments. Fill until water covers all jets but does not touch the bottom of the lowest headrest. (DO NOT OVERFILL!) ImporTanT: Always fill your spa through the filter bucket after draining. Failure to do so may cause air to be trapped in either pump, preventing the pump from circulating water. Remove the hose and replace the filter cartridge. Note: DO NOT overtighten filter cartridge, finger tight only! 3. Turn on power Turn on power to spa at

downloaded: 6   File size: 5 mb   Manafacture: Jacuzzi  
Category: Swimming Pools

11.2 economy Filtration/heating Modes (F4-F6) Economy filtration/heating modes are typically selected by customers in warm climates where heat up times are minimized due to higher ambient temperatures. In these modes, the water temperature is regulated by the set temperature, 24-hour circulation pump, and heater only while a programmed filter cycle is running (unless in summer logic; see Section 14.1, page 38). 11.3 lock modes (l1-l2) These modes are designed for use during spa service or to pre

downloaded: 7   File size: 5 mb   Manafacture: Jacuzzi  
Category: Swimming Pools

However, because heat retentive materials are utilized to insulate the spa for efficient operation, an uncovered spa surface and wall fittings directly exposed to sunlight and high temperatures for an extended period is subject to permanent damage. Damage caused by exposing the spa to this abuse is not covered under warranty. We recommend that you always keep the spa full of water when it is exposed to direct sunlight and that you keep the Jacuzzi premium insulating cover in place at all times w

downloaded: 2   File size: 5 mb   Manafacture: Jacuzzi  
Category: Swimming Pools

10 4.2 Indoor Location............................................................................10 5.0 General Electrical Safety Instructions............................12 6.0 Power Requirements........................................................12 7.0 Electrical Wiring Instructions..........................................15 8.0 Spa Fill Up Procedure ......................................................18 9.0 Control Functions.............................................................2

downloaded: 30   File size: 5 mb   Manafacture: Jacuzzi  
Category: Swimming Pools
@name

• Persons using medication should consult a physician before using a spa since some medication may induce drowsiness, while other medication may affect heart rate, blood pressure, and circulation. • Persons suffering from any condition requiring medical treatment, the elderly, or infants should consult with a physician before using a spa. • The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning. ! 7. warnInG: rIsK oF severe

downloaded: 223   File size: 5 mb   Manafacture: Jacuzzi  
Category: Swimming Pools
@name

• Never allow your jewelry, swimsuit, or hair accessories to come close to the suction fittings, suction covers or skimmer assembly. • Never allow children to play or get near the suction fittings, suctioncovers, filter, filter lid or skimmer assembly. 3.2 Hyperthermia Prolonged immersion in hot water may induce hyperthermia (over heating). The use of alcohol or drugs can greatly increase the risk of fatal hyperthermia in spas. A description of the causes, symptoms, and effects of hyperthermia a

downloaded: 11   File size: 10 mb   Manafacture: Jacuzzi  
Category: Swimming Pools
@name

Contact your dealer or service organization. Note: This message can also appear if the pump has not regained prime after the spa has been drained and refilled. If you suspect that this is the case, see the instructions on page 53 under “pump does not operate but icon does. Ui jrtT lUt Circuit board temperature has exceeded acceptable limit. This message will disappear when the circuit board temperature drops below acceptable limit. If condition persists, provide shade for equipment side of

downloaded: 7   File size: 10 mb   Manafacture: Jacuzzi  
Category: Swimming Pools
@name

Massage Selector (4) • Massage selector 4 controls pump 1 output to footwell IX Jet. Jets Without Massage Selector Controls (5) • Jets 5 are always on when jets pump 2 is running. Page 29 -400 Series 10.14 J-480 Air Controls Diagram Air Controls Operation • Rotate air controls 1-4 to add air to designated jet groups. • Center footwell IX Jet draws air at all times when jets pump 1 is running. This jet has no air control. Page 30 J-400 Serie 10.15 J-470 Massage/Waterfall Selector Diag





Category