Login:
Votes - 3, Average rating: 3.7 ( )

User manual AquaPRO, model PRO1300h/c TCE

Manafacture: AquaPRO
File size: 2.12 mb
File name:
Language of manual:enes
Free link for this manual available at the bottom of the page



manual abstract


The range of hours is “off” to 2, 3, 4,… up to 23 hours to “on”. As described before, the run time will then be calculated and spread out over the 6 time periods for 24 hours. Selecting the “on” position will run the pump and filter system continuously. The unit leaves the factory with the “FIL” mode set to “OFF”. Time Clock Override (TCO) Operation All wiring and electrical connections must be performed by a qualified electrician. Installation must be in accordance with local and national codes. This section allows you the option of using an existing time clock with the heat pump. If you do not have a time clock, please refer back to the Time Clock Eliminator section. The pump must be connected to the heat pump and also the time clock for the Time Clock Override feature to work correctly. See figure 8 for the optional TCO wiring schematic and electrical connections. Phone: (877)-278-2797 6 Figure 7 - PRO1100e TCE & PRO1300 TCE wiring diagram Water Sensor Defrost Sensor High Pressure Switch Closed = OK Opened = High Pressure Low Pressure Switch Closed = OK Opened = Low Pressure Flow Switch Closed = Flow Opened = No Flow MY-TECH PH-111A Brown Brown & White SPR1 SPR2 REVR JANDY HP LP FLO COMPPUMP 12 ~8 ~12 AC F1 F2 F3 WS DS AS P/S Black Black Blue Orange Blue Orange Blue Gray 12 VAC Blue Red Blue 12 / 24 VAC TransformerBlack Yellow Yellow 24 Vac COMPRESSOR R S C 24 VAC Compressor Contactor Coil Run Cap L1L2 Black Black Yellow Black Black RedH C F Red Blue FAN Black Black White 24 VAC pool pump contactor coil L4 Pool Pump L3 To Remote System (If Applicable) •This unit is prepared at the factory with the “FIL” mode set to the “off” position. You will need to set the heat pump’s hours of run time in the “FIL” mode to “2” hours. See “activating and setting system run time” below to set the run time. Leave your time clock set to the desired pump and filter operation time. This will enable the heat pump and filter system to run the desired hours of the day and also provide the benefit of checking if heat is needed every 4 hours. It will do this by running the pump and filter system for 15 minutes. If heat is needed, it will continue to run until the pool has reached the set temperature. If no heat is needed, the system will turn off and continue checking for heat every 4 hours. This provides a couple of added benefits. Pools will lose most of their heat at night if left uncovered, however, since the unit is checking for and adding heat when needed, it prevents long recovery times when compared to non- TCO units. The other benefit is that some states and electric utility companies offer a discount for off-peak usage of electricity. Please contact your electricity provider if you have questions. Activating and Setting System Run Time – TCO Operation •To set the run time of the system, push the “SET” button repeatedly until “FIL” displays. Then using the “up” and “down” arrows, set the hours to “2”. The range of hours is “off” to 2, 3, 4,… up to 23 hours to “on”. By selecting “2” the heat pump will run every 4 hours for 20 minutes, checking if heat is needed. The unit leaves the factory with the “FIL” mode set to “OFF”. Time Clock Override (TCO) Operation (cont.) T2 T1 L3 L4 INSIDE HEAT PUMP CONTACTOR FOR THE TIME CLOCK OVERRIDE TIME CLOCK FILTER PUMP BREAKER Figure 8 - TCO wiring diagram (optional) PRO1100e TCE and PRO1300 TCE Figure 7 - PRO1100e TCE & PRO1300 TCE wiring diagram Water Sensor Defrost Sensor High Pressure Switch Closed = OK Opened = High Pressure Low Pressure Switch Closed = OK Opened = Low Pressure Flow Switch Closed = Flow Opened = No Flow MY-TECH PH-111A Brown Brown & White SPR1 SPR2 REVR JANDY HP LP FLO COMPPUMP 12 ~8 ~12 AC F1 F2 F3 WS DS AS P/S Black Black Blue Orange Blue Orange Blue Gray 12 VAC Blue Red Blue 12 / 24 VAC TransformerBlack Yellow Yellow 24 Vac COMPRESSOR R S C 24 VAC Compressor Contactor Coil Run Cap L1L2 Black Black Yellow Black Black RedH C F Red Blue FAN Black Black White 24 VAC pool pump contactor coil L4 Pool Pump L3 To Remote System (If Applicable) •This unit is prepared at the factory with the “FIL” mode set to the “off” position. You will need to set the heat pump’s hours of run time in the “FIL” mode to “2” hours. See “activating and setting system run time” below to set the run time. Leave your time clock set to the desired pump and filter operation time. This will enable the heat pump and filter system to run the desired hours of the day and also provide the benefit of checking if heat is needed every 4 hours. It will do this by running the pump and filter system for 15 minutes. If heat is needed, it will continue to run until the pool has reached the set temperature. If no heat is needed, the system will turn off and continue checking for heat every 4 hours. This provides a couple of added benefits. Pools will lose most of their heat at night if left uncovered, however, since the unit is checking for and adding heat when needed, it prevents long ...

Other models in this manual:
Swimming Pools - PRO1300 (2.12 mb)
Swimming Pools - PRO1300 TCE (2.12 mb)
Swimming Pools - PRO1300h/c (2.12 mb)
Swimming Pools - PRO1100 (2.12 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category