Manafacture: Linear
File size: 887.15 kb
File name: 15a99cef-da53-4cc1-ad49-bcf882ea83e0.pdf
|
manual abstract
SET TROLLEY 12" FROM PULLEY BRACKET SET TROLLEY LOCATION 12" MAXIMUM DOOR AREA (IN SQUARE FEET) STANDARD SECTIONAL DOORS DOOR SIZE (SQ. FT.) DOOR CONSTRUCTION Insulated Steel Non-insulated Steel Other Construction 250 Fiberglass 210 24 Gauge 22 Gauge Aluminum 180 24 Gauge 20 Gauge Wood 120 20 Gauge 16 Gauge 80 16 Gauge NOTE: On steel insulated doors, a 24 gauge back panel is assumed. 15 Using the Garage Door Operator Opening the Door 1 With the door in view, press the wall station’s UP/ DOWN ARROW button or the button assigned to the operator on the remote control, or enter a valid access code and press START/STOP on a remote keypad. 2 When the operator is activated, the operator’s lights will turn on and the door will begin to open. 3 The door will open until the open limit is reached. If an obstacle is encountered (operator’s lights fl ash four times) while the door is opening, the door will stop. 4 The operator’s lights will stay on for about fi ve minutes after the door stops. Closing the Door 1 With the door in view, press the wall station’s UP/ DOWN ARROW button or the button assigned to the operator on the remote control, or enter a valid access code and press START/STOP on a remote keypad. 2 When the operator is activated, the operator’s lights will turn on and the door will begin to close. 3 The door will close until the close limit is reached. If an obstacle is encountered (operator’s lights fl ash four times), or the safety beam is interrupted (operator’s lights fl ash three times) during closing, the door will stop, then re-open. 4 The operator’s lights will stay on for about fi ve minutes after the door stops. Stopping the Door Mid-travel 1 The door can be stopped immediately at any time by pressing the wall station’s UP/DOWN ARROW button, the remote control’s pushbutton, or press the START/STOP button on a remote keypad. 2 The next time the operator is activated, the door will move in the opposite direction. Vacation Lock for Additional Security 1 Slide the wall station’s LOCK switch to the locked position to prevent remote controls from opening the door after the door is completely closed. The remotes can close the door, but not open it. The door can still be opened or closed by using the wall station’s UP/ DOWN ARROW pushbutton. . NOTE: To signal that the vacation switch is locked, the operator’s lights will fl ash fi ve times if a remote is activated in an attempt to open the door. 2 Slide the wall station’s LOCK switch to the unlocked position to return the operator to normal operation. Controlling the Operator’s Lights 1 The operator’s lights can be lit by pushing the wall station’s LIGHT button. The lights will remain on until the LIGHT button is pressed again or the operator is cycled. 2 If the operator’s lights are on, pushing the wall station’s LIGHT button will turn the operator’s lights off. Disconnecting the Door from the Operator 1 With the door in any position (preferably closed), carefully pull the red release handle. USE CAUTION IF THE DOOR IS OPEN, THE DOOR MAY DROP. 2 The disconnected door can be opened or closed manually. 3 To re-connect the operator, fl ip the release lever up. Raise or lower the door manually until the operator reconnects. 16 Garage Door Operator Maintenance Weather conditions may affect the door operation which could require some re-setting of the operator’s adjustments. Doors may swell and become heavier during wet periods, door hinges and rollers might bind during cold periods. To insure safe operation of the door, perform the following tests, including any additional test steps described. Every Month 1 With the door closed, pull the red release handle to disconnect the operator from the door. 2 From outside the garage, slowly open the door manually all the way, and then close it all the way. Notice if there is any binding, sticking or rubbing. The door should move smoothly in both directions. 3 Raise the garage door about halfway up. Carefully release the door and see if the door balances. It should stay in place. Close the door. . NOTE: If the garage door is unbalanced or the door travel isn’t smooth, have a qualifi ed garage door professional adjust or repair the door. 4 To reconnect the operator, fl ip the release lever up. Raise the door manually until the operator reconnects. 5 Perform the Safety Beam Test (Section 11). 6 Perform the Safety Reversal System Test as described in Steps 4-6 in Section 14. After Servicing the Operator 1 Perform the Safety Beam Test (Section 11). 2 Perform the Open and Close Limit Adjustments (Section 13). 3 Perform the entire Door Force Safety System Test (Section 14). Every 6 Months Check the belt or chain tension. • For belt-drive rails, examine the length of the tension spring in the traveler. It should be about 1” long. • For chain-drive rails, examine the spacing between the turnbuckle and the rail. The turnbuckle should be slightly above the rail. . NOTE: Too much or too little chain tension will cause excessive ...