manual abstract
Check the power connections to the receiver. There must be at least 20 VAC at the receiver power connections. ( If a 24V system) . Review the code switch settings. Any mismatch will prevent the receiver from working. Try a different code switch setting. Check the antenna installation. Wait one minute for the receiver to “ warm- up” . Check battery in transmitter. RECEIVER “ CLICKS” WHEN ANY TRANSMITTER BUTTON IS PUSHED, BUT NOTHING ELSE HAPPENS. Check the wire & connections in the STOP circuit. Refer to Figure 3. Check the OPEN & CLOSE connections. The wire gage may be too small for the number of wall stations used. Check the power to the door operator. Check the door operator’s control voltage. SHORT DISTANCE OR INTERMITTENT OPERATION. Relocate the antenna with a coaxial cable. Metal objects too close to receiver, move to a better location. External interference ( such as radio towers) . Change to a different frequency. Stuck transmitter in building. Change code switches from factory settings. Check battery in transmitter. ONE RECEIVER WORKS BUT THE OTHER IS DEAD. Relocate the antennas. Receivers too close together ( cross-talking) ; move to different locations. Check code switch settings. SOME THINGS TO REMEMBER: Range is dependent on the installation, type of building, type of door and the location of the transmitter. When these conditions change so will the distance. Any transmitter can interfere with operation. These include cell phones, cordless phones, wireless systems and CB and mobile transmitters. Other sources of interference include computer equipment, industrial equipment, electric motors, fluorescent lights, etc. The list is endless. Do not lengthen or shorten the receiver antenna. It is set to an optimal length based on the frequency of operation. If the antenna is blocked or shielded ( such as a car traveling through a tunnel) the distance will decrease. Always change the Factory set codes. LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twelve ( 12) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s nor- mal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabili- ties on the part of Linear LLC for consequential damages arising out of or in connection with use or per- formance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number ( RPA#) . Con- tact Linear Technical Services at 1- 800- 421- 1587 for an RPA# and other important details. Page 4 of 4 P/ N 190-104780 REV D USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 Toll Free FAX (800) 468-1340 linearcorp. com 831 COMMERCIAL RECEIVER INSTRUCTIONS MODELS: • ···· 831-S, 24 VAC & 115 VAC • ···· 831-J, 24 VAC & 115 VAC READ THIS MANUAL CAREFULLY BEFORE BEGINNING PRODUCT FEATURES 831 Commercial Receivers are designed to work with most commercial door operators. The 831 is connected to the commercial operator in the same manner as a 3-button station and provides open, close and stop functions via radio control. The receiver may be powered from the operator’s 24 VAC transformer or from a 115 VAC circuit. There is ample room in the 831 control box to make the proper connections. The antenna is removable and may be moved ( using coaxial cable) to a new location for better RF reception. IMPORTANT INSTALLATION NOTES WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH: READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS! • 831 RECEIVERS ARE INTENDED FOR USE WITH COMMERCIAL DOOR OPERATORS ONLY. DO NOT USE FOR ANY OTHER PURPOSE. DO NOT MODIFY IN ANY MANNER. • CHECK LOCAL BUILDING AND ELECTRICAL CODES FOR MANDATORY INSTALLATION AND WIRING REQUIREMENTS. • CONNECT POWER CORDS ONLY TO A PROPERLY GROUNDED OUTLET. IF PERMANENT WIRING IS REQUIRED BY CODES, DISCONNECT POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE ATTEMPTING ANY WIRING CONNECTIONS. • DO NOT WEAR RINGS, WATCHES OR LOOSE CLOTHING WHILE INSTALLING OR SERVICING GARAGE DOOR OPENERS. WEAR SAFETY GOGGLES OR OTHER PROTECTIVE EYEWEAR. • AN UNBALANCED DOOR OR ONE THAT STICKS OR BINDS MAY CAUSE INJURY OR DEATH. ENSURE DOOR IS PROPERLY BALANCED AND ELIMINATE ANY STICKING OR BINDING. • YOUR GARAGE DOOR IS A LARGE MOVING OBJECT. THE SPRINGS, PULLEYS, CABLES AND MOUNTING HARDWARE UTILIZED TO BALANCE ITS OPERATION ARE UNDER EXTREME TENSION AT ALL TIMES AND CAN CAUSE SERIOUS PERSONAL INJURY, EVEN DEATH, IF DISTURBED. ONLY A QUALIFIED...
Other models in this manual:Safety Gate - 831-S (111.85 kb)