Login:
Votes - 2, Average rating: 3 ( )

User manual Genie, model INTELLIG 3024

Manafacture: Genie
File size: 5.34 mb
File name: intellig-1000-install.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Rail door arm is attached to the garage door .. Safe-T-Beam® units installed and wired • Wall console installed and wired .. Door arm carriage is engaged to the chain or belt drive .. Power head is plugged into an approved power outlet Begin programming by setting Limits on the next page. A PDF VERSION INSTALLATION POSTER IS AVAILABLE AT WWW.GENIECOMPANY.COM OR CALL 1.800.354.3643 TO OBTAIN AN EMAIL PDF FILE ©2010 The Genie Company 01/27/2010 6 ©2010 The Genie Company 01/27/2010 PROGRAM SET — + 5 SECS SETTING & TESTING LIMITS AND FORCE The OPEN (UP) and CLOSE (DOWN) Door Limit positions are controlled by making adjustments using the panel located on the bottom of the power head. Begin with Step 1 and continue through Step 10. Door Force is set during the final Open/Close cycle of these steps. The power head will automatically set door speed at slow if the distance between limits is less than 6 feet. A) CLOSE DOOR TRAVEL LIMIT NOTE: You can start and stop door movement using either buttons until door is in correct open or closed position. Watch door move PROGRAMMING LIMITS & FORCE (Continuing from Installation Poster if provided) 1 GRAM SE — + 5 PRESS and HOLD PROGRAM SET — + PRESS and HOLD SEE BOTH Blue LEDs come ON SEE round Blue LED come ON PROGRAM SET — SEE round Blue LED flashing RELEASE 1 2 3 4 NOTE: If one or both LEDs come ON RED at this time; Limits programming menu was not entered properly. You must exit programming and restart. To exit this mode: A. Press PROGRAM SET and release B. Pause C. Press PROGRAM SET and release D. Pause E. Begin with Step 1 on this page. Restarting at Step 1 will reset RED LEDs to BLUE. PRESS and RELEASE WARNING • Make sure doorway is in view and clear of obstacles and people to avoid injury or damage to property. • DO NOT operate this unit from wall console before LIMITS and FORCE are set. Severe damage to the opener can occur. • Bullet MUST be engaged to carriage BEFORE setting limits. See Installation Poster (if provided) or refer to pages 12 and 18. Please note that there is a 30 second timeout between each programming step. A programming timeout during these steps has occured when two RED flashing LEDs appear. In the event of a timeout please restart at Step 1. NOT CE OR CM UC D U ON N H D Travel door to FULL CLOSED position RELEASE PRESS and RELEASE SEE long Blue LED come ON If RED LED comes ON - STOP and exit programming. ©2010 The Genie Company 01/27/2010 7 PROGRAM SET — PRESS SEE long Blue LED flashing 6 Watch door move RAM SET — + B) OPEN DOOR TRAVEL LIMIT NOT E OR M O R C D OW O AD DOOR CLOSES DOOR OPENS Door Limits are set. Both LEDs go OFF. Continue with FORCE setting. SET FORCE Force is set automatically with first full OPEN/CLOSE door operation. 7 8 9 10 Continue with programming remotes on the next page of this manual. PRESS and RELEASE PRESS and HOLD PRESS and PRESS and RELEASE RELEASE PROGRAM SET — Travel door to FULL OPEN position RELEASE NOTE: You can start and stop door movement using either buttons until door is in correct open or closed position. 8 ©2010 The Genie Company 01/27/2010 PROGRAM SET — + 5 SECS PROGRAM SET — + 2 PROGRAM INTELLICODE® 2 REMOTE TO POWER HEAD FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM PRESS and HOLD SEE BOTH Blue LEDs come ON SEE round Blue LED come ON SEE long Purple LED flashing SEE long Purple LED come steady ON RELEASE 1 2 3 4 5 6 7 The next press of the remote will operate door. Repeat as necessary for other remotes. Bring remote(s) to power head location. Begin with Step 1 and continue through Step 7 for each button to be programmed. NOTE: The following instructions are for the remote(s) provided with this opener. Remote(s) provided with this opener use a IntelliCode® 2 electronic access code system. Refer to page 15 for additional information on IntelliCode® 1 and 2 remotes. See page 9 for programming instructions using IntelliCode® 1 remotes. PRESS and RELEASE PRESS and RELEASE PRESS and RELEASE Basic power head programming is complete. Your garage door opener is ready to use. WARNING A moving door can cause serious injury or death. 1. Keep people clear of opening while door is moving. 2. Do NOT allow children to play with opener, including wall console, remote, or wireless keypad. 3. During programming, door opener could begin to run, so stay away from moving door and its parts. SEE both LEDs OFF SEE both LEDs flash Blue PRESS and RELEASE OPTIONAL PROGRAMMING POWER HEAD TO Homelink®, Car2U®, or IntelliCode® 1 REMOTES and SERIES II WIRELESS KEYPADS To complete any of these tasks you MUST have at least one Genie® IntelliCode® 2 remote button already programmed to the power head. Homelink® or Car2U®: You must also have your Homelink® or Car2U® enabled vehicle present and their programming instructions to perform these programming steps. Genie® remote: You must also have your Genie® IntelliCode® 1 remote present. Genie® wireless keypad: You must also have your Genie® wireless keypad installed and a PIN already progr...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category