Login:
Votes - 2, Average rating: 3.5 ( )

User manual JVC, model BR-DV600U

Manafacture: JVC
File size: 1009.18 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


fade function ON/OFF. V.fade reduces audio noise at the tag recording during playback. Setting: OFF (00): The V. fade function is not activated. qON (01): Activates the V. fade function. 245 SAMPLING RATE Details: Selects the sampling rate frequency when recording audio digitally. Setting: 32K (00): Records signals at a 32 kHz sampling frequency. Set to this position for audio dubbing on CH3 and CH4. q48K (01): Records signals at a 48 kHz sampling frequency. Audio dubbing is not possible with this setting. 311 AUTO PLAY Details: Selects whether or not playback starts automatically after the tape is rewound to the beginning. Setting: qSHORT FF (00): The tape stops after short FF. Auto play does not start. PLAY (01): Auto play starts. Repeat playback is available when No. 312 menu switch is set to “ ON” . 312 AUTO REW Details: Selects whether or not the tape is rewound automatically at tape end during recording or playback. Setting: qOFF (00): The tape is not rewound automatically. ON (01): The tape is rewound automatically. Repeat playback is available when No. 311 menu switch is set to “ PLAY” . 353 EDIT ADJUST Details: When this unit is used with an editing controller and the edit-in point is shifted, this corrects the play start timing. Switch setting differs depending on the configuration of the editing system. For details, refer to “ Edit adjust setting” on page 16. Setting: q0F: No compensation. 1F: The playback start point is delayed by 1 frame. 2F: The playback start point is delayed by 2 frames. 3F: The playback start point is delayed by 3 frames to the factory set timing. 4F: The playback start point is delayed by 4 frames. 5F: The playback start point is delayed by 5 frames. 6F: The playback start point is delayed by 6 frames. 7F: The playback start point is delayed by 7 frames. 360 AUTO REW AT TIMER Details: Selects whether or not the tape is automatically rewound when the VCR power is switched ON in the Timer Play or Recording Standby mode. Setting: qOFF (00): Playback or recording starts immediately. The tape is not rewound. ON (01): Playback or recording starts after the tape is rewound to the beginning. 363 CONTROLLER SELECT Details: Selects the setting according to the type of remote control unit connected via the RS422A interface. Setting: qTYPE 1 (00): For the RM-G820. TYPE 2 (01): For a non-linear editing system. TYPE 3 (02): Unused. : TYPE 8 (07) 396 BATTERY SELECT Details: When using DC power, set this switch according to the DC power supply and battery type. Setting: q12 V (00): Select this setting to use a DC power supply (AA-G10) or DC 12 V flat shape type battery. 13.2 V (01): Select this setting to use Anton Bauer Inc. ’ s Trimpack 13, ProPac 13. 14.4 V (02): Select this setting to use Anton Bauer Inc. ’ s Trimpack 14, ProPac 14 and IDX Corporation's NP-L46. For servicing See the service manual page 1-19 “ 1.11 SET UP SW” . < 4-2 Menu switch details 4 MENU SWITCHES PHONES REMOTE LOCAL EJECT OPERATE REC LEVEL CH-2/4 CH-1/3 ON/OFF VIDEO CASSETTE RECORDER BR-DV600U 0 [AUDIO MONITOR] switch q: Factory setting (00): The number in the bracket shows the set value on the counter display. 397 FAN STOP SHUTDOWN Details: Sets whether or not VCR operation continues if the fan motor stops. Setting: qENABLE (00): The power turns off about 1 minute after the fan motor stops. DISABLE (01): The VCR continues operation even after the fan motor stops. When the fan motor stops, press the [OPERATE] button as soon as possible to turn the VCR’s power off. If not, a malfunction may occur due to overheating. 414 TCG SELECT Details: Selects the time code generator mode. Setting: qPRESET (00): Engages the Preset mode. REGEN (01): Engages the Regen mode. 415 TCG MODE Details: Selects the time code generator Run mode. Setting: FREE RUN (00): Engages the Free Run mode. qREC RUN (01): Engages the Rec Run mode. 416 NON DROP/DROP (U MODEL) Details: Selects the time code generator Drop Frame mode. Setting: qDROP (00): Engages the Drop Frame mode. NON DROP (01): Engages the Non-Drop Frame mode. 500 ON SCREEN Details: Selects whether or not the on-screen display is shown on the monitor. Setting: OFF (00): The display is not shown. qON (01): The display is shown. 501 CHARACTER H.POSITION Details: Moves the display position of the tape counter on screen, etc. horizontally. Setting: q0 (00) The display position can be moved in : 9 steps from 0 to 8. The factory setting is 8 (08) “ 0” (the display position at the far right). * The tape remaining time indication position cannot be changed. 502 CHARACTER V.POSITION Details: Moves the display position of the tape counter on screen, etc. vertically. Setting: 0 (00) The display position can be moved in q 1 (01) 12 steps from 0 to 11. When the No. 504 : menu switch is 11 (11) set to “ MODE + TIME>, setting to “ 0” is not possible. * The tape remaining time indication position on screen can be changed up and down with this switch. 504...

Other models in this manual:
Cameras - BR-DV600E (1009.18 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category