User manual Frigidaire, model CHDE5300AW

Manafacture: Frigidaire
File size: 3.01 mb
File name:
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer. 6. The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45kPa). 7. The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa). A WARNING 9 English LOCATION OF YOUR DRYER Do Not Install Your Dryer: 1. In an area exposed to dripping water or outside weather conditions. 2. I n an area where it will come in contact with curtains, thick carpet, or anything that will obstruct the flow of combustion and ventilation air. 3. On carpet, floor must be solid with a maximum slope of linch (2.54 cm). Any floor unevenness should be corrected with leveling legs located on the bottom of the dryer. Installation in Alcove or Closet: 1. DO NOT install your dryer in a closet with a solid door. 2. A dryer installed in a bedroom, bathroom, alcove or closet MUST be exhausted outdoors. 3. No other fuel burning appliance shall be installed in the same closet as the gas dryer. 4. Refer to the images on this page to ensure the installation provides the minimum amount of clearance required for ventilation. 5. When installing the dryer in a closet with a door, a minimum of 120 square inches (774.2 square cm) of ventilation in the door is required. Openings must be equally divided at the top and bottom of the door and airflow must be unobstructed. A louvered door with equivalent air openings for the length of the door is acceptable. 10 English LOCATION OF YOUR DRYER IN A CLOSET OR RECESSED AREA Following are instructions concerning and the minimum clearances required for any closet, recessed area, or customized under-counter installation: • Additional distances facilitate installation and servicing. • Addtional clearances might be required for wall, door and floor moldings. • Additional distances of 1 in. (25.4mm) on all sides of the dryer is recommended to reduce noise transfer. • For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. Companion appliance spacing should be considered. < 1 >k (25.4mm) 32. 5" (825mm) A ( 76mm) 11 English MANUFACTURED (MOBILE) HOME INSTALLATION 1. Dryer MUST be exhausted outside (outdoors, not beneath the manufactured home) using metal ducting that will not support combustion. Metal ducting must be 4 inch (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred. 2. If dryer is exhausted through the floor and area beneath the manufactured home is enclosed, the exhaust system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure. 3. When installing a g...

Other models in this manual:
Dryers - CHDE5000AW (3.01 mb)
Dryers - CHDE5300AW (3.01 mb)
Dryers - HDE5000AW (3.01 mb)
Dryers - CHDE5000AW (3.01 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category